Laserfiche WebLink
Appendix 4 <br />• <br />}SPARE <br />I1PARE <br />/BEACON <br />00' <br />400'R <br />4 <br />8 BARE WIRE Y_ <br />COUNTERPOISE <br />WIRE. 4'MIN <br />L-833 <br />TRANSFORMER <br />CONCRETE ANCHOR <br />WAY 6X 6'X12' MINIMUM <br />30' METAL STOKE <br />DETAIL "C. ID <br />BACKFILL PER---ZI6 <br />SPEC L 108 <br />*8 BARE COPPERS <br />COUNTERPOISE <br />WIRE. <br />INSULATED CABLE <br />NOTE: CABLE TRENCH TO BE <br />2FT OUTSIDE OF LIGHT FIXTURES. <br />HER€NCH DETAIL REVERSE SIDE <br />AND CABLE PLACEMENT <br />NOTE: SEE SHEET 7 FOR DUCT <br />MARKER DETAILS <br />AUXILIARY <br />CONTROL <br />CIRCUITS <br />AUXILIARY BREAKERS 15 AMPERE <br />NEUTRAL TERMINAL <br />BLOCK <br />REGU- <br />LATOR <br />DETAIL ' B' <br />1.5' <br />DUCTS ARE <br />3' INSIDE <br />IS DIAMETER <br />2 WAY DUCT DETAIL <br />4 WAY DUCT DETAIL <br />SPEC L-811 POWER AND CONTROL CABINET <br />4 KW ASSEMBL f <br />120/240 VOLT <br />3 WIRE AC <br />SUPPLY <br />MAIN BREAKER <br />RUNWAY POWER <br />CONTROL BREAKER <br />BRIGHTNESS <br />SELECTOR L <br />RUNWAY SELECTOR <br />}WIND COTE <br />}OSST. LIGHTS <br />\ 1 MISC. OR SPP <br />`f <br />120 VOLT AC DIRECT CONTROL FOR L-81I REGULATOR <br />L-821 CONTROL PANEL <br />SPST <br />TOGGLE I <br />SWITCH <br />J <br />AUXILIARY RELAY <br />COIL 5,000 OHMS <br />CONTACTS -SILVER <br />5 AMPS 120 VOLTS <br />r <br />120V. CURRENT <br />BREAKER PANEL <br />L-813 REGULATOR 4 KW I <br />1-1'240 VOLT INPUT <br />Li SUPPLY <br />SERIES TAXIWAY CIRCUIT <br />3- Vc W6 <br />VASI-2 ADAPTER UNIT <br />TO RUNWAY <br />LIGHTING <br />CIRCUIT , <br />2- 1/c#8 <br />REGULATORI- <br />VASI-2 <br />UNIT <br />CABLES <br />IN COMMON <br />TRENCH <br />or— 2- WAG <br />120 V <br />SOURCE <br />MOUNT( <br />BASE. <br />MULTIPLE CONNECTION OF VASI-2 <br />L-833 <br />TRANS <br />I/C NO L-924 <br />CABLE <br />LIGHT FIXTURE• <br />1' THIN - WALL COND. <br />BREAKABLE COUPLING <br />AND DISCONNECT PLUG <br />m=I <br />SEE <br />DETAILS' <br />I/O, 40,3K,L-B24 <br />TYPE B' CABLE <br />L-823 CONNECTORS <br />4 USE L-802 FOR THE RUNWAY <br />AND L-822 FOR TAXIWAYS <br />TYPICAL STAKE MOUNTED <br />FIXTURE DETAIL <br />in N <br />10' FROM EDGE OF RUNWAY <br />VASI-2 UNIT 700' <br />(2 LOCATIONS) I 1 <br />10 SPACES <br />AT 200' <br />14.5' <br />TAXIWAY EXIT SIGN <br />SEE SPEC <br />L-829 <br />BREAKABLE <br />COUPLING 2' <br />- MOUNTING FLANGE <br />- CABLE CONNECTOR <br />CLAMP <br />- 30'ANGLE IRON <br />STAKE <br />6' X 6' X 12' <br />CONCRETE ANCHOR <br />WHERE SPECIFIED <br />TELLTALE LAMP <br />(CONNECT TO TOP 5 BOTTOM POST) <br />GROUND LEAD (CENTER POST <br />OT LEAD (TOP POST) <br />511P RING BINDING POST <br />`CONNECTION. <br />POWER <br />POLE <br />REGULATOR AND <br />PANEL LOCATION IN <br />NORTHWEST CORNER <br />OF BUILDING. <br />2-I/C•6 VASI-2 <br />NOTES TO THE DESIGNER <br />I. THE DESIGN SHOWN 15 PREDICATED UPON THE <br />FUTURE EXTENSION OF THE TAXIWAY LIGNTNG <br />SYSTEM FOR A PARALLEL TAXIWAY THE LENGTH <br />OF THE RUNWAY. <br />2. IN THE EVENTS TAXIWAY LIGHTING IS <br />NEEDED, THE SYSTEM CAN BE SIMPLIFIED BY <br />USE OF THE L-811 REGULATOR. SEE ADVISORY <br />CIRCULAR 150/5340-6B FOR DETAILS. <br />3. INSTALLATION OF THE COUNTERPOISE <br />--BQI SYSTEM IS JUSTIFIED ONLY IN AREAS <br />ROTATING HAVING FREQUENT ELECTRICAL STORMS. <br />BEACON. 4. THE CONCRETE ANCHOR FOR THE LIGHTING <br />FJXTIRFS MAY BE ELIMINATED WHERE <br />SOIL CONDITIONS ARESTABLE. <br />5. AC150/5340-I5A (ENTRANCE EXIT SIGNING) <br />185' 185' • 30' <br />• T <br />1BN IR5' as'1 I 10 <br />SEE DETAIL 'A. <br />ADAPTER I VA51-2 <br />TGO' <br />UNIT.152' - IDG <br />ON TRENCH <br />L-807 WIND CONE ASSEMBLY (SEGMENTED CIRCLE) <br />RUNWAY AND TAXIWAY LIGHTING LAYOUT <br />SCALE: I'- 100' <br />POSITION OF BEACON <br />MOUNTING LEGS. <br />2'1(4' BELOW�t <br />SUPPORT POLE <br />LIGHTNING ROD <br />ALL WOOD MATERIAL <br />TO BE CREOSOTED <br />12 LBS RETENTION. <br />I/2'DIA X 5' <br />COPPER CLAD <br />LIGHTNING ROD 1 <br />CLAMP TO POLE <br />W/STD CONDUIT <br />FITTINGS. <br />NO.6AWG BARE <br />STRANDED GROUND, - <br />WIRE CLAMP TO <br />BASE OF LIGHTING <br />ROD., <br />THREE MOUNTING FLANGES <br />SPACED 120' APART ON <br />,12,E DIAMETER CIRCLE o <br />�I PIPE NIPPLE WIRE ENTRANCE <br />TO BEACON EXTENSION OF MOUNTING BASE. <br />i OBSTRUCTION LIGHT <br />- CONNECTION. J— y4 <br />cm, <br />1 <br />J <br />2 I/C NO.8 AWG WIRES <br />TO TOWER BASE. <br />L-801 BEACON <br />WIRING DIAGRAM <br />5/B'X 8' COPPER CLAD <br />GROUND ROD. <br />-2'X6" 8REQb. <br />-OBSTR LIGHT <br />O <br />• <br />Ba <br />a■ <br />-SUPPORT POLE 0 <br />v <br />MOUNTING HOLES III DIA. <br />25(12"�`�`� <br />LL <br />PLATFORM PLAN 3REQb POSITIONED AS <br />SHOWN <br />OBSTR. LIGHT L-810 <br />WIRED INTO TE <br />TALE CIRCUIT. <br />1' RIGID GALV. CONDUIT <br />HOLES 3REOb. I <br />rAILEI <br />LAP JOINT <br />FUSED <br />WEATHERPROOF <br />IjSSW13OAFETYAMPW/LOCITCHK IA <br />I I/2' GALV. RIGID; <br />CONDUIT <br />2-I/C NO. BANG <br />3KV L-824 CABLE <br />TPE LB CONDULET <br />i DIA THRU BOLTS <br />W/WASHER <br />I' CONDUIT W/2 •10 AWG <br />POLE STEPS-18'0.C. <br />ALTERNATE EACH <br />SIDE OF POLE <br />2 - 35 POLES MIN TOP <br />DIAMETER 6' CREOSOTED <br />12 LBS RETENTION. <br />BOTTOM POLE STEP <br />AT APPROX 8' FROM <br />3L0' <br />DOUBLE POLE MOUNTING DETAIL <br />IN <br />fOR L-8Ol BEACON <br />'SPACE RESERVED FOR <br />NECESSARY APPROVALS <br />IHB <br />-I VAST-3UNIT- <br />(2 LOCATIONS) <br />200' <br />LEGEND <br />RUNWAY LIGHTS <br />TAXIWAY LIGHTS <br />THRESHOLD LIGHTS <br />CABLE <br />TAXIWAY EXIT SIGN TWO FACE <br />TAXIWAY EXIT SIGN ONE FACE <br />VA31-2 UNIT <br />VAS1-2 ADAPTER UNIT <br />ClIFZR LIGHT GLOBE <br />2'%12' <br />7X6 <br />At <br />LAP JOINT <br />(NAILED) <br />7X4' <br />rE11A THRU BOLT <br />e W / WA HERS <br />T <br />18'(TYP) <br />-L <br />5'MIN <br />LAP JOINT <br />POLE STEP <br />1 NCI AWED VASI -2 <br />REVISION BYIAPPfMR <br />CITY OF AERVILLE <br />AERVILLE, U.S.A. <br />AERVILLE MUNICIPAL AIRPORT <br />LIGHTING LAYOUT, <br />DIAGRAM 8 DETAILS <br />(CONSULTING FIRM) <br />DRAWN BY I CHECKED BY <br />SCALE I DATE 110 OF 11 <br />WIRING DIAGRAM FOR RUNWAY,TAXIWAY. VASI-2 BEACON AND WIND CONE <br />