Laserfiche WebLink
-406- <br /> <br />go <br /> <br />The maximum length of cut-de-sac streets shall be 600 feet, measured along <br />the centerline from~the intersection of origin to the end of the right-of-way. <br />Each cul-de-sac shall have a terminus of nearly circular shape with a <br />minimum right-of- way diameter of 130 feet and a minimum roadway <br />diameter of 100 feet. <br /> <br />ho <br /> <br />In those instances where a subdivision abuts or contains an existing or <br />planned thoroughfare or a railroad right-of-way, the planning commission <br />may require a service street approximately parallel to and on each side of <br />such right-of-way <br /> <br />Half streets shall be prohibited except where essential to the reasonable <br />development of the subdivision in conformity with the requirements of this <br />Chapter. <br /> <br />Private streets shall be permitted in accordance with applicable zoning <br />district.. <br /> <br />Street right-of-ways shall not be planned so as to cause hardship to owners <br />of adjoining property. <br /> <br />The angle formed by the intersection of streets shall not be less than 75 <br />degrees, with 90-degree intersections preferred as measured 100 feet from <br />the intersection. Intersections of more than four comers are prohibited. <br /> <br />mo <br /> <br />A tangent of at least 100 feet in length shall be introduced between reverse <br />curves on thoroughfare and collector streets and a tangent of at least 50 feet <br />in length shall be introduced between reverse curves on ali other streets, <br />unless otherwise approved by the City Engineer. <br /> <br />Roadways of street intersections shall be rounded by a radius c_ <br />than 20 feet for suburban type streets and 30 feet for rural type streets. <br />Roadways of alley-street intersections shall be rounded by a radius of not <br />less than ten feet. <br /> <br />Subd. 4. Public Utilities <br /> <br />Sanitary sewers and water facilities shall be installed in accordance with the <br />standards and specifications as required by the Council and subject to the <br />approval of the City Engineer. <br /> <br />The use of individual water and sewer systems in accordance with all <br />appropriate State and local regulations. <br />In an area not having municipal storm sewer trunk, the applicant shall be <br />responsible, before platting, to provide for a storm water disposal plan in <br />accordance with the City's Comprehensive Drainage Plan without damage to <br /> <br />9.50 Subdivision Regulations <br /> <br />9-28 <br /> <br />March 2003 Draft <br /> <br /> I <br />I <br />I <br />I <br />I <br />I <br />i <br />I <br />I <br />I <br />I <br />I <br />! <br />I <br />I <br />I <br />I <br /> I <br /> I <br /> <br /> <br />