MEMORANDUM <br /> <br />COM]VL NO: 98009 DATE: <br /> Ra _wt~ey Senior Hous/ng <br /> Ramsey, <br /> <br />TO: File <br /> <br />.Tohn R.ova <br /> <br />8 September 1998 <br /> <br />Phone conversation with Mr. Dean Kapler - City oflLarnscy Fire Chief, 4 September 1998. <br /> <br />I <br />! <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />I <br />I <br />I <br />I <br /> <br />We discussed thc features oft. he building relating to ~'e and smoke conta{nment. <br /> <br />2. <br />3. <br />4. <br /> <br />Type V - 1 hour construction - floors I, 2 and 3. <br />Type I construction at garage. <br />2 hour separation pea- except/an Table 6-A. <br />Decided to provide a N'FPA. 13 sprinkler system (with dry system in attic). Thus our building arca - <br />6,349 sq. ft., floor 1-3 is under the 84,000 sq. ft. allowable and no firc separation partitions are <br />necessary. <br />Thc attic space will have draft stops located at one corridor partition line and horizontal at apartment <br />demising line with maximum spac/ng of 100 fL Attic access panels occur at each stairway and a 2x12 <br />plank walkway is located longitudinally. <br />Chief Kaplcr was satisfied with these features and said he would not find objection to a variance in <br />building height as proposed. <br /> <br />COPIES TO: <br /> <br />ChiefKaplcr- City ofl/am;ey ~7- <br />Sylia Frolik - City ofP. amscy, Zoning Administration <br />Tom Dillon - DDC <br /> <br /> <br />