My WebLink
|
Help
|
About
|
Sign Out
Home
09/01/98
Ramsey
>
Public
>
Dissolved Boards/Commissions/Committees
>
Board of Adjustment
>
Agendas
>
1990's
>
1998
>
09/01/98
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2025 1:58:35 PM
Creation date
9/18/2003 12:07:06 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Document Title
Board of Adjustment
Document Date
09/01/1998
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CASE #: I <br /> <br /> REQUEST FOR A VARIANCE TO HEIGHT RESTRICTIONS <br />FOR A SENIOR HOUSING FACILITY; CASE OF CITY OF RAMSEY AND ANOKA <br />COUNTY HOUSING AND REDEVELOPMENT AUTHORITY <br /> By: Zoning Administrator Sylvia Frolik <br /> <br />Background: <br /> <br />As you know, the City is working in conjunction with the Anoka County Housing and <br />Redevelopment Authority to develop a 50 unit senior housing faciIity on Dysprosium Street, <br />across the street from the City water tower. The City Code establishes a maximum height <br />structure of 35 feet based on the reach capability of Fire Department equipment. The proposed <br />structure is 3-stories high and will exceed the 35 foot height restriction. <br /> <br />Observations: <br /> <br />The City Code def'mes building height as the measurement from the mean ground level to the <br />uppermost point of the roof. The mean ground level at the facility will be 874.5 feet and the <br />highest point of the roof is 919.0 feet; this calculates out to a 9.25 foot encroachment of the 35 <br />foot height restriction. <br /> <br />The Fire Chief indicates that the maximum reach capability of the Fire Department for fire <br />suppression and rescue operations is 38 feet. Concern is expressed relating to the possible need <br />to evacuate persons of limited physical ability and agility down an extension ladder, and the <br />impairment of fire suppression activities resulting from equipment that cannot reach the roof line. <br />Ramsey does have a joint powers agreement with the Anoka and Andover Fire Departments for <br />emergency assistance and those departments do have aerial ladder tracks with reach capabilities <br />in excess of 80 feet. The Fire Chief also notes that an aerial ladder truck is in Ramsey's 2005 <br />capital equipment plan and that acquisition schedule should be escalated. <br /> <br />The architect indicates that the distance from the mean ground level to the third story window <br />heads is 29.5 feet and 24.5 feet to the sills. <br /> <br />According to the Uniform Building Code, all dwelling units and public areas of the building will <br />have to be equipped with a fire suppression system (automatic sprinkler system). <br /> <br />The following items are enclosed for your information: <br /> <br />a) <br />b) <br />o) <br />d) <br />e) <br /> <br />Site location map <br />Modified building exterior elevations with height measurements <br />Memo from Fire Chief Dean Kapler dated August 25, 1998 <br />Proposed Findings of Fact <br />Proposed Variance <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.