Laserfiche WebLink
§ 8.3O <br /> <br />for said permit, sb,~] pay a fee therefore of $15.00. Such permits shall be valid for a <br />period of six months from date of issue. <br /> <br /> Subd. 2~ Applications for permits shall be <br />printed blanks or forms furnished by the council and shall be signed by <br />applicant. <br /> <br /> Sub& 3~ Each application for a permit shall have thereon the correct <br />legal description of the property on which the proposed installation; alteration, <br />repair or extension is to take place, and each application for a permit shah be <br />accompsn~ed by a plot plan of the land showing the location of any proposed or <br />existing buiMings located on the property with respect to the boundary lines of the <br />property and complete plans or the proposed system with substantiating data, if <br />necessary, attesting to the compliance with the r,~nimum standards <br />chapter. A complete plan shall include the location, size and design of all parts of <br />the system to be installed, altered, repaired or extended. <br />show the present or proposed location of water supply facilities and water supply <br />piping and the n~r~e of the person, firm or corporation who is to install the system, <br />and shall provide such further information as may be required by the council. <br /> <br />Construction requirements. <br /> <br /> Subdivision l. Site evaluation. Ail proposed sites for individual <br />sewage treatment systems shall be evaluated by the tRamsey Plumbing Inspector in <br />accordance with §9.13 (Soils) and §9.50 (Subdivision). <br /> <br />Page 240 <br /> <br />Sub& 2. Building sewers <br /> <br />a. <br /> <br /> h perm~t~: shall be slid for ~ <br /> <br /> be made in writing upon <br /> .nd shall be signed by the <br /> <br /> Lal! have thereon the correct <br /> sed installation; alteration, <br /> ation for a permit shah be <br /> location of any proposed or <br /> to the boundary lines of the <br /> with substantiating data, ii <br /> ~nimum standards of this <br /> ze and design of all parts of <br /> [. The application she]] also <br /> facilities and water supp]y <br /> who is to install the system, <br /> squired by the council. <br /> <br /> ~posed sites for individual <br /> msey Plumbing Inspector in <br /> <br />The building sewer and all piping up to the point where the <br />disposal field soil treatment area begins shall be of watertight <br />piping and joints. Joints between this piping and other <br />appurtenances of the system shall be watertight. The use of <br />perforated pipe or its equivalent is prohibited. <br /> <br />No building drain or building sewer shall be less than 4 inches in <br />diameter. <br /> <br />The buried or concealed portion of any building sewer, building <br />drain or branch thereof~ shall be located at least 9~0 feet from any <br />welt. That portion located less than 50 feet from any well shaI] be <br />constructed of cast iron pipe with air tested joints. The air test <br />should be made by attaching an air compressor or test apparatus <br />to a suitable opening and closing all other in]ets and outlets to the <br />sewer and/or drain under test by means of proper testing plugs. <br />Air shall be forced into the system until there is uniform pressure <br />of 5 pounds per square inch in the section being tested. The <br />system sha].] be considered satisfactorily air tested if the pressure <br />therein remains constant for 15 minutes without the addition of <br />air. <br /> <br />Printed 12/28/90 <br /> <br /> <br />