My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council Work Session - 01/10/2012
Ramsey
>
Public
>
Agendas
>
Council Work Session
>
2012
>
Agenda - Council Work Session - 01/10/2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2025 12:04:04 PM
Creation date
1/11/2012 3:44:56 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council Work Session
Document Date
01/10/2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
186
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
fire protection, Staff has prepared an alternative scenario for the same space currently occupied by Hope Fellowship, <br />but evaluated a different occupant type. Staff evaluated the space as a bowling center instead of a church. A <br />bowling center is still an 'A-3', but could be rated for an occupant load of 350 people. Under 1306 it would need <br />fire suppression due to the fact it's an 'A-3' occupant type. Without 1306, the building code would require <br />suppression for occupant load or a fire wall could be added. With the occupant load fewer than 300 on both sides of <br />the rated wall, fire suppression would not be needed. <br />The Building Official discussed the bowling center scenario with a contractor. The contractor's thoughts were that <br />the upfront cost difference between fire suppression and a fire wall would be roughly one quarter to one third less <br />with a fire rated wall when compared to fire suppression. The contractor also commented that his company always <br />directs owners to look into cost savings over time due to insurance reductions. In other words, savings on insurance <br />premiums due to installation of a fire suppression system may help off -set the costs of installing a fire suppression. <br />Staff has not researched actual costs savings on insurance premiums at this time. In addition, there may be impacts <br />to the City's ISO rating based on the inclusion of Chapter 1306. <br />In terms of the question of legality of IUPs, Minnesota Statute Section 462.3 597 does provide the City with the <br />authority to allow interim uses that allow a temporary use of a property until a particular date, until the occurrence <br />of a particular event, or until the zoning no longer allows it. It should be noted that an IUP is a tool related to <br />zoning and permitted use of a property. <br />Recommendation: <br />Based on discussion. <br />Funding Source: <br />Review of the Building Code provisions related to fire protection systems is being handled as part of regular staff <br />duties. <br />Council Action: <br />Based on discussion. Provide direction on Chapter 1306 of the Building Code. <br />IUP-Minnesota Statute 462.3 597 <br />Attachments <br />Form Review <br />Inbox Reviewed By Date <br />Heidi Nelson Heidi Nelson 01/05/2012 01:19 PM <br />Kurt Ulrich Kurt Ulrich 01/05/2012 02:03 PM <br />Form Started By: Tim Gladhill Started On: 12/29/2011 03:07 PM <br />Final Approval Date: 01/05/2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.