Laserfiche WebLink
Pre -Demolition Survey Techtron Engineering, Inc. <br />8020 —147`h Ave. NW, Bldg. 1 Ramsey, MN TEI Job# F12-2879 <br />XRF Testing- Flaking Paint August 29, 2012 <br />Conclusions <br />None of the flaking/delaminating surfaces coatings tested at the property were found to be <br />lead -based paint. All surfaces tested by XRF had lead contents less than the EPA threshold <br />of 1.0 mg/cm2. <br />Prepared by: <br />Techtron Engineering <br />Andy Turbitt <br />Lead Inspector/Risk Assessor <br />