Laserfiche WebLink
8020 — 147th Ave NW, Building 2, Ramsey, MN <br />Techtron Job#: F12-2879 B <br />Techtron Lab #: PLM-12-15542 <br />Client Lab ID <br /># # <br />Sample Location <br />1 38617 Front entry, ceiling <br />2 38618 Front entry rest room, <br />ceiling <br />3A 38619 Dock 3, wall <br />3B <br />3C <br />4A <br />4B <br />5 <br />6A <br />38620 <br />38621 <br />38622 <br />38623 <br />38624 <br />38625 <br />Dock 3, wall <br />Dock 3, wall <br />Upstairs break area, ceiling <br />Upstairs break area, ceiling <br />Upstairs break area, wall <br />Upstairs kitchenette, floor <br />6B 38626 Upstairs kitchenette, floor <br />7A 38627 Upstairs kitchenette, floor <br />7B 38628 Upstairs kitchenette, floor <br />8A 38629 Dock 3 restroom, floor <br />8B 38630 Dock 3 restroom, floor <br />9A 38631 Front entry restroom, floor <br />9B 38632 Front entry restroom, floor <br />10 38633 Upstairs furnace, line <br />breach <br />11 38634 Exterior ground A/C unit, <br />line wall breach <br />12 38635 Exterior, wall breach <br />13A 38636 Exterior, roof <br />13B 38637 Exterior, roof <br />NAFD = No Asbestos Fibers Detected <br />Sample Description Asbestos Results <br />White texture <br />White texture <br />White joint compound, top <br />layer <br />Tan joint tape, 2nd layer <br />White sheet rock, 3rd layer <br />White texture, top layer <br />White sheet rock, 2nd layer <br />White sheet rock <br />Cream/off-white/gray <br />linoleum <br />Cream/white mastic from <br />sample #6A <br />Cream/off-white/gray <br />linoleum <br />Cream/white mastic from <br />sample #7A <br />Tan/cream/gold specks, <br />rectangle pattern linoleum <br />Clear yellow mastic from <br />sample #8A <br />Tan/cream/gold specks, <br />rectangle pattern linoleum <br />Clear yellow mastic from <br />sample #9A <br />Black, gummy wrap <br />Cream/gray putty/caulk <br />Black/gray putty/caulk <br />Shingle w/brown rock <br />Shingle w/black rock <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />NAFD <br />Limit of Detection: 1 %. Some samples may contain asbestos fibers in quantities below the PLM detection limit of 1 %. Results are based on <br />field sampling information provided by the client and are only valid for samples tested. Samples are stored for 30 days unless other <br />arrangements are made by the client. Samples received in good condition unless otherwise noted. This report shall not be reproduced <br />except in full, without the written approval of Techtron Engineering. <br />Page 2 of 2 <br />