Review File: Brookfield 4th Addition <br />Preliminary Plat Request <br />Engineering Review <br />Page 3 of 3 <br />Items that must be updated prior to approval of the Preliminary plat are noted below: <br />• Storm sewer inverts in Blocks 4 and 6 require adjustment, upstream inverts are lower than <br />downstream inverts. <br />• Rim and invert labels must be added for all manholes and catch basins. <br />• Labels must be moved to point to the appropriate structure. <br />• The font size/ pen weight of labels must be increased to make plan readable. <br />Stormwater Pollution Prevention Plan: The Stormwater Pollution Prevention Plan must be <br />modified as follows: <br />Update the disturbed area number. <br />Change text discharg' to discharge. <br />Change water quality volume from 1/2 inch to 1 inch per Lower Rum River WMO and the <br />MPCA construction stormwater permit requirements. <br />Add item 7.11 — `Remove soils tracked onto City streets with a pickup broom within 3 <br />hours of notification by City.' <br />Landscaping Plan: The south and east sides of the plat adjoin existing single family rural lots. <br />The landscaping plan does not show screening between the urban and rural lots. <br />These comments apply to the preliminary plat submittal. The Final Plat documents and <br />construction plans will be subject to further review and comment. <br />