My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 12/10/2013
Ramsey
>
Public
>
Agendas
>
Council
>
2013
>
Agenda - Council - 12/10/2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2025 9:41:17 AM
Creation date
12/11/2013 10:22:34 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
12/10/2013
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 08340 <br />INSULATED ROLLING SERVICE DOORS <br />PART 1 GENERAL <br />1.1 SUMMARY <br />A. Section Includes: Manual overhead insulated rolling doors. <br />B. Related Sections: <br />1. 05 50 00 Metal Fabrications. Door opening jamb and head members. <br />2. 06 10 00 Rough Carpentry. Door opening jamb and head members. <br />3. 08 31 00 Access Doors and Panels. Access doors. <br />4. 08 70 00 Hardware. Padlocks. Masterkeyed cylinder. <br />5. 09 91 00 Painting. Field painting. <br />6. Division 26. Electrical wiring and conduit, fuses, disconnect switches, connection of <br />operator to power supply, and installation of control station and wiring. <br />D. Alternates: <br />1. Cornell Iron Works <br />2. Amarr <br />3. Clopay <br />1.2 SYSTEM DESCRIPTION <br />A. Design Requirements: <br />1. Cycle Life: <br />a. Design doors of standard construction for normal use of up to 20 cycle per day <br />maximum. <br />2. Insulated Door Slat Material Requirements: <br />a. Flame Spread Index of 10 and a Smoke Developed Index of 50 as tested per <br />ASTM E84. <br />b. Minimum Sound Transmission Class (STC) rating of 26 (22/22GA) or 33 <br />(18/22GA) as tested per ASTM E90. <br />c. Minimum R-value of 4.6 and U-value of 0.217 (polystyrene insulation) or R- <br />value of 6.29 and U-value of 0.159 (polyurethane insulation) as calculated using <br />the ASHRAE Handbook of Fundamentals. <br />d. Insulation to be CFC Free with an Ozone Depletion Potential (ODP) rating of <br />zero. <br />1.3 SUBMITTALS <br />A. Reference Section 01 33 00 Submittal Procedures; submit the following items: <br />1. Product Data. <br />2. Shop Drawings: Include special conditions not detailed in Product Data. Show <br />interface with adjacent work. <br />3. Quality Assurance/Control Submittals: <br />a. Provide proof of manufacturer ISO 9001:2008 registration. <br />08340-1 Doc 9.013 <br />
The URL can be used to link to this page
Your browser does not support the video tag.