My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 05/13/2014
Ramsey
>
Public
>
Agendas
>
Council
>
2014
>
Agenda - Council - 05/13/2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 4:19:09 PM
Creation date
5/14/2014 3:59:03 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
05/13/2014
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
397
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7080.2210 INDIVIDUAL SUBSURFACE SEWAGE TREATMENT SYSTEMS 48 <br />7080.2200 TYPE I SYSTEMS. <br />Systems designed according to parts 7080.2200 to 7080.2240 are considered Type I systems. <br />Statutory Authority: MS s 115.03; 115.55 <br />History: 32 SR 1347 <br />Published Electronically: October 10, 2013 <br />7080.2210 TRENCHES AND SEEPAGE BEDS. <br />Subpart 1. Characteristics. To qualify as a trench or seepage bed system, the system must meet the <br />requirements of items A to E: <br />A. employ flow values in parts 7080.1850 to 7080.1885; <br />B. meet applicable technical requirements of parts 7080.1900 to 7080.2030, 7080.2050, and <br />7080.2100; <br />C. provide flow measurement if a pump is to be employed; <br />D. meet the requirements of part 7080.2150, subparts 2 and 3, except subpart 3, item M; and <br />E. meet the requirements of subparts 2 to 4. <br />Subp. 2. General. Seepage bed placement must be limited to areas having natural slopes of less than <br />six percent. Absorption areas for seepage beds and trenches must not be placed in soils with a loading rate <br />of less than 0.45 gallons per day per square foot or as shown in Table IX or IXa in part 7080.2150, subpart <br />3, item E. Seepage beds must not be located in floodplains. <br />Subp. 3. Sizing of trenches and seepage beds. <br />A. The trench bottom absorption area is calculated by dividing the design flow by the <br />appropriate soil loading rate in Table IX or 1Xa in part 7080.2150, subpart 3, item E. If gravity distribution <br />is used in seepage beds, the seepage bed absorption area is calculated by dividing the design flow by the <br />soil loading rate in Table IX or IXa in part 7080.2150, subpart 3, item E, multiplied by 1.5. If pressure <br />distribution is used in seepage beds, the seepage bed absorption area is determined by dividing the design <br />flow by the soil loading rate in Table IX or IXa in part 7080.2150, subpart 3, item E. <br />B. The minimum sidewall absorption is six inches. The bottom absorption area is allowed to <br />be reduced, for trenches only, by the following: <br />Sidewall absorption - inches Bottom area reduction <br />12 to 17 20% <br />18 to 23 34% <br />24 40% <br />A 40 percent reduction is not allowed with a loading rate of 1.2 gallons per day per square foot. <br />Copyright ©2014 by the Rev <br />so <br />of Statutes, State of Minnesota. All Rights Reserved. <br />
The URL can be used to link to this page
Your browser does not support the video tag.