Laserfiche WebLink
Review File: Fire Station No. 2 (5650 Alpine Dr NW) <br />Site Plan Review: Comprehensive Plan and Zoning Code <br />November 26, 2014 <br />Page 3 of 5 <br />The site also is the location of an Anoka County Public Safety Communications Tower (800 MHz). An existing <br />easement allows for ingress and egress, as well as siting of the tower. Based on the modified access, it is suggested <br />that this easement be amended to reflect the new site plan and access. <br />Comprehensive Plan: The Property is designated as Public/Quasi-Public in the Comprehensive Plan. This category <br />generally includes City offices, public works facilities, churches, school, other non-profit or government facilities, and <br />bridges/major rights -of -way. The proposed use appears to be consistent with this designation. <br />Zoning: The Property is located within the Public/Quasi-Public Zoning District, which is guided by City Code Section 117- <br />122. The intent of the Public/Quasi-Public District is to provide for and regulate uses that are public or semi-public in nature <br />and to provide community with area designated specifically for open spaces, community gather places, public and private <br />recreational spaces, educational facilities, and government buildings. Government buildings and facilities are a permitted use <br />within this District. The proposed use appears to be consistent with this District. <br />Dimensional Standards. While City Code Section 117-122 guides permitted and prohibited uses within the District, it does <br />not contain specific dimensional and performance standards. It has been the City's practice and policy to review proposed <br />developments located within the Public/Quasi-Public utilizing the B-1 General Business District dimensional standards found <br />in City Code Section 117-114 when located adjacent to residential districts. For purposes of this review, the City will utilize the <br />standards of the B-1 General Business District to review the proposed Fire Station. The proposed site plan appears to be <br />consistent with the standards below. <br />Standard <br />Re. ' - is - • Pro.osed <br />• • ' • •• •. Lot Width <br />.•.• <br />• •t Death <br />Maximum Building Height <br />• • ' • •• •• Front Yard Setback <br />• • ' • •• •• Side Yard Setback <br />%P[•r its Lr ti•xr ilit• •1ic•rr•ra�:t•r� <br />• • ' • •• •• Rear Yard Setback <br />Major and minor arterials and State and County Roads <br />us- <br />•• ' • • Setback from P - ' • - • 1 istricts <br />0.5 acres <br />100 feet <br />150 feet <br />35 feet <br />35% <br />35 feet <br />10 feet <br />20 feet <br />35 feet <br />60 feet (centerline) <br />25 feet <br />2.34 feet <br />272 feet <br />350 feet <br />35 feet' <br />10% <br />78 feet <br />36 feet <br />36 feet <br />36 feet <br />N/A <br />N/A <br />1 <br />20 feet 20 feet <br />35 feet 36 feet <br />Architectural Standards. All exterior wall finishes shall be either face brick, stucco, glass, wood, natural stone, specifically <br />designed pre -cast concrete units whose surfaces have been integrally treated with an applied decorative material or texture or <br />other materials approved by the City. Combinations of these materials shall be permitted. The proposed building is <br />predominately brick, with precast units, metal, and glass used for accent. The Project Management Team has chosen <br />a pitched roof design, as opposed to a flat roof design, to better integrate with the adjacent residential development. <br />The proposed renderings appear to be consistent with these standards. <br />' The hose tower measures approximately thirty-seven (37) feet. City Code Section 117-358 (Permitted encroachments) exempts fire <br />and hose towers from height limitations. <br />