Laserfiche WebLink
During construction, staff will evaluate the construction limits for each driveway and will <br />work with each of property owner to determine the proper overlay limits in the field. <br />Right -of -entry forms may be needed from residential property owners to complete work <br />outside City right-of-ways and easements. <br />Pedestrian Facilities: <br />Pedestrian facilities exist along several of the street segments proposed to receive an <br />overlay. Staff will evaluate potential impacts to each facility in the field to determine <br />whether any adjustments are needed. <br />4.2 Stormwater Improvements <br />No widening of streets is proposed with this project so stormwater improvements are proposed to <br />be limited to casting adjustments of storm sewer structures. <br />4.3 Water Main Improvements <br />No watermain improvements are proposed with this project. <br />4.4 Sanitary Sewer Improvements <br />No sanitary sewer improvements are proposed with this project. <br />4.5 Construction Methods <br />An edge mill will first be performed along the curb line of each street segment. Then all existing <br />metal castings for sanitary sewer, storm sewer, and watermain infrastructure will be raised, after <br />which the pavement will be swept to remove any loose debris. A coating of bituminous tack <br />material will then be applied to the existing pavement which serves as a glue to adhere the <br />bituminous overlay to the existing bituminous pavement. Each street will then receive a 11/2" <br />bituminous overlay lift. <br />If required, pavement striping will be completed last. <br />4.6 Private Utilities <br />Staff has not yet met with telephone, gas, and/or cable utilities regarding this project. If the City <br />Council orders this project, staff will meet with the private utility companies as noted in the <br />project schedule included in this report to discuss the proposed improvements, and to determine <br />if modifications are feasible to minimize impacts to private utilities, including potential power <br />pole impacts. <br />Should any utility company decide to upgrade, replace, or otherwise modify their services during <br />the project, any such upgrades, replacements, or modifications will be at the sole discretion and <br />cost of the private utility company. <br />City staff will contact Connexus Energy to determine if they would like to bury any of their <br />overhead lines with this project. <br />Feasibility Report <br />2015 Street Maintenance Program, Division B: Overlay Improvements <br />City of Ramsey Project No. 15-00 <br />Page 5 <br />