Review File: Sunwood Village <br />Plat/ Site Plan Request <br />Engineering Review <br />Page 3 of 3 <br />C3-2 — Revise typical street section - 6" Premium Topsoil, 6' wide sidewalk, all references to <br />Class 5 shall read Class 5, Ramsey Modified. Gradation is shown on Ramsey Street Details. Use <br />Ramsey Detail STR-25 for connection to existing street. Revise the SWPPP to conform with the <br />requirements of the MPCA Construction Stormwater permit. <br />C4-1 — All storm sewer pipes in public ROW shall be RCP. <br />Remove or label dark line on nw corner of plan. <br />C8-1 — Concrete sidewalk Detail — Sidewalk shall be 6" thick. <br />Add information to Concrete Washout detail — 10 mil poly, ground shall slope away from area, <br />how deep is the pit, <br />The MNDOT 5 sheet curb ramp details must be added to set. <br />A custom detail is required for each pedestrian ramp and must include spot elevations, slopes and <br />layout of detectable warnings. <br />Specifications were not submitted. These notes are required when the specifications are <br />submitted. <br />• Include City where ever Engineer or Owner is referenced in Specifications. <br />• General Statements - Include City in notifications to Engineer and Owner. <br />• Sunday work is not permitted in the City of Ramsey without City Council approval. <br />Working hours are 7:00 am — 10:00 pm, Monday —Saturday, 48 hour notice is required for <br />Saturday Work. <br />• The contractor must have a City License. <br />• A City right-of-way permit is required prior to working in the ROW. <br />Water — Add Notes: <br />• Only City Personnel shall operate valves. <br />• All valves not in paved surfaces shall have blue carsonite markers. <br />• Paragraph 2.7.C.2 — Valve nut extensions are not used in the City of Ramsey. <br />Sanitary Sewer — Add note: <br />• All manholes not in paved surfaces shall have green carsonite markers. <br />• All sanitary sewer shall have 10 gauge solid copper tracer wire. <br />Storm Sewer — Add note: <br />• All manholes not in paved surfaces shall have green carsonite markers. <br />• All storm sewer shall have 10 gauge solid copper tracer wire. <br />Landscaping — Include City on all Correspondence. <br />• All plant material in City ROW shall have two (2) year warranty <br />