My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 09/13/1983 - Special
Ramsey
>
Public
>
Agendas
>
Council
>
1983
>
Agenda - Council - 09/13/1983 - Special
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2025 12:02:38 PM
Creation date
4/20/2004 3:03:13 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Title
Special
Document Date
09/13/1983
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> I <br /> I <br />I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br />I <br /> I <br /> I <br /> <br />FROM: <br /> <br />RE: <br /> <br />DA'YE: <br /> <br />City Administrator <br /> <br />Building Official <br /> <br />Expansion of LomLs N. Graves Company, Inc. <br /> <br />Auqust 15, 1983 <br /> <br />I today reviewed both the site and the site plan for the above referenced <br />expansion. My comments on the site plan, building plans and site are <br />as follows: <br /> <br /> 1) The proposed addition is to the south of the existing building <br />and will be located where there is presently a shed roof addition, several <br />small storage buildings and two trailers which are being used for storage. <br /> <br /> 2) The site plan does not show the existing house, existing garage <br />or any proposed parking. <br /> <br /> 3) If the site plan is accurate, the existing on-site septic system <br />is located in the blacktop driveway. <br /> <br /> 4) One structure shown on the site plan as a storage shed is <br />actually a box car. <br /> <br /> 5) At the time I visited the site, there were 12 or 13 cars parked <br />in the area. There was no additional parking available. <br /> <br />6) The frost footings, as proposed, do not meet code. <br /> <br /> 7) The wall openings necessary to negate the need for a sprinkler <br />system are not shown. <br /> <br />8) The building heat loss calculations were not provided. <br /> <br /> 9) The plans have not been signed by a registered architect or <br />engineer. <br /> <br />10) The plans are not complete. <br /> <br />Inasmuch as this is only an expansion, it would be my recommendation <br />that this proposed addition be approved contingent upon the following: <br /> <br />I <br />I <br /> <br /> 1) That the applicant shall comply with all requirements of the <br />building code. <br /> <br />2) That the site plan shall show the existing house and garage. <br /> <br /> 3) That the site plan shall show proposed parking and that said <br />parking, including one handicap site, shall be properly marked. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.