BKV <br />GROUP <br />Architecture Interior Design Landscape Architecture Engineering <br />Phone: 612.339.3752 Fax: 612.339.6212 www.bkvgroup.com <br />Enriching Lives and Strengthening Communities <br />AIA® Document G714TM — 2007 <br />Construction Change Directive <br />PROJECT: <br />Ramsey Fire Station #2 <br />5650 Alpine Drive NW <br />Ramsey, MN 55303 <br />TO CONTRACTOR: <br />Brennan Construction <br />5985 Bandel Rd NW <br />Mankato, MN 56001 <br />DIRECTIVE NUMBER: CCD-02 <br />DATE: February 23, 2016 <br />CONTRACT FOR: New Construction <br />CONTRACT DATED: April 15, 2016 <br />ARCHITECT'S PROJECT NUMBER: <br />1937.01 <br />OWNER: <br />ARCHITECT: <br />CONSULTANT: ❑ <br />CONTRACTOR: <br />FIELD: ❑ <br />OTHER: ❑ <br />You are hereby directed to make the following change(s) in this Contract: <br />Generator <br />-Provide a generator annunciator panel and mount panel on an interior wall of Room 108. Control <br />conduits are run from the generator set to the mechanical area 202. Provide a conduit and wiring <br />from the mechanical area to Room 108 as required by generator manufacturer. <br />Lighting <br />- Provide one light at each of the office entries to be on overnight. To accomplish this, Rapid can tie <br />one can light to the exterior soffit lighting. This will be controlled by a photo cell and will illuminate <br />the area dusk to dawn. <br />- Provide (3) recessed can lights located in the high ceiling at entrance 117 on dusk till dawn. Rapid can <br />tie these to the can lights in this area also. Control will be by photo sensor. <br />- Verify that red lights have dimming driver installed <br />- Dimmers for exterior red lights are to be mounted high in the apparatus bay. "Intercept" the conduit <br />feeding the fixtures with a 4"x4"x2.5" junction box. Junction box shall be mounted at or above 8 <br />feet. One for the east fixtures and one for the west fixtures, and a dimmer switch would be installed <br />in each of the two junction boxes. See attached cut sheet for dimmer. <br />PROPOSED ADJSUTEMENTS <br />1. The proposed basis of adjustment to the Contract Sum or Guaranteed Maximum Price is: <br />n Lump Sum of $ <br />n Unit Price of $ per <br />AIA Document G714TM - 2007. Copyright © 2007 by The American Institute of Architects. All rights reserved. Warning: <br />This AIA® Document is protected by U.S. Copyright Law and International Treaties. Unauthorized reproduction or <br />distribution of this AIA® Document, or any portion of it, may result in severe civil and criminal penalties, and will <br />be prosecuted to the maximum extent possible under law. <br />User Notes: <br />(1184281017) <br />1 <br />