Laserfiche WebLink
CONVERSION FROM GROUND ONLY (NO NEUTRAL)TO NEUTRAL WIRING <br />This product is pre -configured for wiring without a neutral; however, if connection to neutral is required by code, the unit easily converts in seconds. <br />Step 1: <br />Remove Yellow <br />Label <br />WIRING TO GROUND (NO NEUTRAL) <br />VIO (+) <br />GRY (-) DIMMING <br />Step 2: <br />Loosen Screws and <br />Remove Metal Link <br />Step 3: <br />Connect Neutral to <br />Silver Screw and <br />Ground to Green <br />Screw <br />WIRE COLOR KEY <br />120/277 VAC WIRING <br />EBLACK*- Linelnput *BLACK wires <br />BLACK* - Load Output can be reversed <br />VIOLET - Low Voltage Dim Output (0-10 VDC) <br />GRAY -Low Voltage Common <br />LOAD 347 VAC WIRING (-347 Option) <br />Red wires replace Black wires. <br />WIRING TO NEUTRAL <br />11 GND <br />r <br />BLK <br />BLK <br />VIO (+) <br />GRY (-) —1 DIMMING <br />NOTES: <br />1.) Per NEC requirements, the 0-10Vviolet and gray wires must be installed as Class One. <br />2.)The 0-10V control wires must not exceed 250 ft (76 m) in length and must be sized at no less than 20 <br />AWG. <br />OPERATIONAL SETTINGS <br />2= Time Out <br />Time after which light will tum OK One minute priorto expiation, LED on <br />dimmer will begin blinking and the light level in the space will adjust to 3 <br />VDC <br />1 =Off* 5=60.0min 9=720.0min <br />2=10.0min 6=90.0min <br />3=15.0min 7=120.0min <br />4 = 30.0 min 8 = 180.0 min <br />9= Restore Defaults <br />Returns all functions to original settings. <br />1 - Maintain Current* <br />2 - Restore Defaults <br />15= Dimming Range Max (High Trim) <br />The maximum output level of the sensor. <br />1-OVDC 5-3VDC 9-7VDC 13-10VDC* <br />2-1VDC 6-4VDC 10-8VDC <br />3-1.5VDC 7-5VDC 11 -9VDC <br />4-2VDC 8-6VDC 12-9.1 VDC** <br />**Default for EZoption <br />16 = Dimming Range Min (Low Trim) <br />The minimum output level of the sensor. <br />1-OVDC 5-3VDC 9-7VDC 13-10VDC <br />2-1 VDC* 6-4VDC 10-8VDC <br />3 -1.5 VDC** 7 - 5 VDC 11 - 9 VDC <br />4-2VDC 8-6VDC 12-9.1 VDC <br />**Default for EZ option <br />19 = Fade 0n Rate <br />Time rrequired for light to reach preset level. <br />1-0.75sec* 3-5sec <br />2-2.5sec 4-15sec <br />20 = Fade Off Rate <br />Time required for light to tum Off <br />1-0.75sec 3-5sec <br />2-2.5sec* 4-15sec <br />21= Start Level <br />Level of light output when switched on. <br />1-10% 5-50% 9-90% <br />2-20% 6-60% 10-100%* <br />3-30% 7-70% <br />4-40% 8-80% <br />* Default Setting <br />❑N <br />LOAD I — <br />Acuity Brands l One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com ©2014-2016Acuity Brands Lighting, Inc. All rights reserved. 02/02/16 2 of 3 <br />