Laserfiche WebLink
ASBESTOS MATERIAL SURVEY <br /> CITY BUILDING <br /> 15240 HELIUM STREET NW <br /> RAMSEY, MINNESOTA <br /> 2.1 LIMITATIONS <br /> EPA Inc. made reasonable attempts to access all areas of the building as presented <br /> within the scope of this work. The following areas and/or materials were not able to be <br /> accessed or due to safety concerns or other limitations. <br /> • A limited number Of penetrations were made in the exterior structure walls to identify <br /> if insulation fill (i.e. vermiculite) was used. Fiberglass was identified. <br /> • No roof samples were collected from the building, This roof had a rubber <br /> membrane system with no evidence of an original roof system or other suspect <br /> materials under the roof membrane. <br /> $.0 BUILDING DESCRIPTION <br /> The project consisted of a one-story commercial building with a full basement/garage <br /> area. <br /> • The interior walls are primarily metal framing with sheetrock application <br /> • The exterior walls on the building are brick <br /> • The floors consist mostly of carpet on concrete with linoleum in the bathroom <br /> • The roof is a ballast rubber membrane system <br /> 4.0 SUSPECT BUILDING MATERIALS <br /> Representative bulk samples of suspect ACM building materials were collected from the <br /> duplex. The identified materials that were considered suspect and subsequently <br /> sampled include: <br /> • 2x4'Ceiling Tile 0 Sheetrock/jt compound <br /> • Flooring materials • Caulking <br /> • Carpet Glue Exterior damproofing <br /> • Mopboard/glue Roofing materials <br /> Of the materials sampled, none were found to be asbestos containing.- <br /> No <br /> ontaining:No special actions are required. <br /> Please refer to the following section for the analytical laboratory results, including <br /> material locations, and quantities. <br /> 15240 Helium St NW,Ramsey,MN 2 02012 EPA, Inc <br />