Laserfiche WebLink
I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />i <br />I <br />! <br /> <br />I <br />I <br /> <br />I <br />I <br />I <br />I <br /> <br />-6- <br /> <br />disposal field soil treatment area begins shall be of watertight piping and <br />Joints. Joints between this piping and other appurtenances of the system shall <br />be watertight. The use of perforated pipe or its equivalent is prohibited. <br /> <br /> 2. No building drain or building sewer shall be less than four (4) <br />inches in diameter. <br /> <br /> 3. The buried or concealed portion of any building sewer, building <br />drain or branch thereof s~all be located from the well as specified by the <br />State Board of Health and the State Plumbing Code. <br /> <br /> 4. The portions of any buried sewer more than fifty (50) feet from a <br />well shall be constructed of material as approved by the State Pl~a~ing Code. <br /> <br /> 5. All joints between pipes and fittings in the building sewer shall <br />have watertight and root-tight joints. Portland cement mortar joints shall not <br />be allowed. Lines shall provide a grade of not less than one-eighth (1/8) inch <br />per foot. Where building sewers exceed fifty (50) feet in length, lines shall <br />provide a grade which will allow a flow velocity of not less than two (2) feet <br />per second. In no case shall the grade exceed two per cent (2.0%). Ail changes <br />of grade shall be by means of long sweep ells. Where long sweep ells are not <br />used and where the direction changes by more than twenty and one-half (20-1/2) <br />degrees, accessible watertight cleanouts shall be provided. <br /> <br />150.014C SEPTIC TAblKS <br /> <br />Subd. 1 GENERAL <br /> <br />Ail tanks, regardless of material or method of construction, shall be: <br /> <br />dj <br /> <br />Me <br /> <br />One (1)piece, precast; <br />Watertight; <br />So designed and constructed as to withstand all lateral earth <br />pressures under saturated soil conditions with the tank <br />empty; <br />So designed and constructed as to withstand a minim~ of <br />seven (7) feet of saturated earth cover above the tank top; <br />Not subject to excessive corrosion or decay. <br /> <br />Subd. 2 DESIGN <br /> <br />Ail tanks, regardless of material or method of construction, shall conform to <br />the following design criteria. <br /> <br /> 1. The liquid depth of any septic tank or compartment thereof shall be <br />not less than thirty (30) inches. A liquid depth greater than six and one-half <br />(6-1/2) feet shall not be considered in determining tank capacity. <br /> <br /> 2. No tank or compartment thereof shall have an inside horizontal <br />dimension less than twenty-four (24) inches. <br /> <br /> <br />