Laserfiche WebLink
EMSL Analytical, Inc. <br />14375 23rd Avenue North, Minneapolis, Mn 55447 <br />Phone/Fax: (753) 449-4922 I (763) 449-4924 <br />ht1A'Ifvrlww,emsl.com minneaAolislak a)emsl.Com <br />Attn: Jim Lindahl <br />Environmental Property Audits, Inc <br />2701 4th Avenue North <br />Anoka, MN 55303 <br />Project: 15153 Nowthen Blvd <br />Phone: (763) 323-6700 <br />Fax: (763) 323-6677 <br />Received_ 12/11/12 2:40 PM <br />Analysis Date: 12/11/2012 <br />Collected: <br />EMSL Order: 351207840 <br />CustomerlD: ENVP52 <br />Customer PO: <br />Projectld: <br />Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA <br />600/M4-82-020 Method(s) using Polarized Light Microscopy <br />Sample <br />12-01510 B-38 <br />351207840.0001 <br />12-01510 0-39 <br />351207640-0002 <br />12-01510 a-40 <br />351207840-0003 <br />12-01510 B-41 <br />351207840.0004 <br />Analyst(s) <br />Nicholas Asuncion (4) <br />Non -Asbestos <br />Description Appearance % Fibrous % Non -Fibrous <br />Exterior Black 94% Non -fibrous (other) <br />Dampproofing Fibrous <br />Homogeneous <br />Senior Kitchen White 92% Non -fibrous (other) <br />Sink Soundproof Non -Fibrous <br />Homogeneous <br />Boiler Stack InsuI. White 20% Cellulose 75% Non -fibrous (other) <br />Middle Fibrous 5% Synthetic <br />Homogeneous <br />Boiler Stack Insul. White 20% Cellulose 75% Non -fibrous (other) <br />South Fibrous 5010 Synthetic <br />Homogeneous <br />Asbestos <br />% Type <br />6% Chrysotile <br />8% Chrysotile <br />None Detected <br />None Detected <br />„6,7 <br />Rachel Travis, Laboratory Manager <br />or other approved signatory <br />EMSL maintains iiahility limited to cost of analysis. This report relates only to the samples reported and may not he reproduced, except in Full. without written approval by EMSL. EMSL bears no <br />responsibility ter sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must notbe used by the client to claim <br />product certification. approval. or endorsement by NVLAP, NISI or any agency of the federal government. Non -friable organically bound materials present a problem matrix and therefore EMSL <br />recommends gravimetric reduction prior to analysis, Samples received in good condition unless otherwise noted. Estimated accuracy. precision and uncertainty data available upon request. Unless <br />requested by the client, building materials manufactured wish multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% <br />Samples analyzed by EMSL Analytical. Inc. Minneapolis, Mn NVLAP Lan rf,rf. 200019.0 <br />I Initial report from 12/12/2012 07:28:53 <br />Test Reoort PLM-7.16.0 Printed: 12/12/2012 7:28:53 AM <br />THIS IS THE LAST PAGE OF THE REPORT, <br />