My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 08/28/1984
Ramsey
>
Public
>
Agendas
>
Council
>
1984
>
Agenda - Council - 08/28/1984
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2025 11:18:31 AM
Creation date
7/13/2004 1:57:55 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
08/28/1984
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Hakanson Anderson Associates, Inc. <br /> engineers and surveyors <br /> 222 Monroe Street <br /> noko. Minnesota 55303 612/427-5860 <br /> <br />'1 <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> <br />August 21, 1984 <br /> <br />Mr. Ken Bombach <br />Metropolitan Waste Control Commission <br />350 Metro Square Building <br />7th and Robert Streets <br />St. Paul, MN 55101 <br /> <br />Re: Ramsey Second Connection <br /> MWCC Project No. 83-62 <br /> <br />Dear Ken: <br /> <br />As the Ramsey City Engineer, I have assisted and reviewed the design <br />of the above referenced project. <br /> <br />Ramsey's Comprehensive Sanitary Plan (CSP) shows an average flow from <br />the Rum River Watershed of 3.52 MGD. The CSP provides for the <br />development of wetlands and public lands. <br /> <br />By deleting wastewater flow from wetlands and public lands, the esti- <br />mated average flow from the Rum River Watershed is 3.12 MGD. This <br />estimated flow is based on the assumption that areas outside the <br />M.W.C.C.'s Sewer Service Area No. 3 will not be served. <br /> <br />Based on a design average flow of 3.12 MGD and a peak flow of 11.59 <br />cubic feet per second (CFS), the proposed thirty inch line at 0.08 <br />percent grade is adequate to meet the City of Ramsey's sewer needs. <br />The proposed invert of 835.2 is also consistent with the City's future <br />trunk sewer system. <br /> <br />As requested last week, I have enclosed a copy of Table 18 from the <br />Ramsey Comprehensive Plan which gives wastewater flow projections from <br />1985-1990 for the Rum River Watershed (Ramsey Second Connection). <br />These projections were made in 1982 and they appear to be one to two <br />years ahead of schedule. A more realistic flow for 1985 would be 0.01 <br />to 0.015 MGD. <br /> <br />~'h'i/ · mtttm'ipa; · 'planni~:;~ · ~,,:,/., a lan,! surn'vin.t: <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.