My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 07/24/1978
Ramsey
>
Public
>
Agendas
>
Council
>
1978
>
Agenda - Council - 07/24/1978
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2025 2:53:21 PM
Creation date
8/5/2004 2:09:03 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
07/24/1978
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
be permitted within the flood plain unless <br />emergency plans and procedures for action to <br />be taken in the event of flooding are prepared, <br />filed with, and approwd by th_'. ilinnesc, ta <br />POlldtion .Contr. ol Agoncy~ ~ l~h3 emerg3ncy <br />plans and' ~rocedures must provide for measur6s <br />to pruv~nl~ introduction of any pollutant or <br />to.xic mzterial in{.o th~ flood ¥~ators. .. <br /> <br />(b) There shall be no disposal of garbage or solid <br /> ¥~aste materials ~.:ithin flood fringe areas except <br /> upon issuance of a Conditional Use Permit at <br /> sites approved by the l.)innesota Pollution Control <br /> ,~,gency. <br /> <br />Flood Control ?lorks. Flood control ?;orks shall <br />be subject to the provisions of Section 13-11~..5,H, <br />and the following provisions: <br /> <br />(a) <br /> <br />The minimum height and design of any dikes, <br />levees, floodwalls or similar structural works <br />shall be based upon the flood profile of the <br />regional flood confined between the structures <br />subject to the follm,ying: <br /> <br />For urban areas the minimum height and <br />design of structural v.~orks shall be at <br />least three feet above the elevation of <br />the regional flood or at the elevation of <br />the standard project flood, whichever is <br />greater. <br /> <br />Hodifications and additions to existing <br />structural ?~orks shall assure that the work <br />will provide a moans of decreasing tile <br />flood damage potential in tile area-. Any <br />existing strL~ctural work ~?hich potentially <br />threatens public health or sa:fury shall <br />be modified or reconstructed in order to <br />meet the standards contained herein within <br />a period of one year of the effective date <br />of this Ordinance. <br /> <br />Flood protection elevations and floodway limits <br />which reflect proposed measures for flood control <br />shall not be effective until such measures <br />are constructed and operative unless the proposed <br />measures will incr. ease flood heights, in which <br />event, the regulatory flood protection elevations <br />and flood plain limits shall reflOct'the anticipated <br />.increa§es. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.