My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 02/28/2017
Ramsey
>
Public
>
Agendas
>
Council
>
2017
>
Agenda - Council - 02/28/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 3:04:45 PM
Creation date
3/1/2017 1:35:34 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
02/28/2017
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
325
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Review File: Brookfield 8th Addition <br />Final Plat Exhibits <br />Engineering Review <br />February 7, 2017 <br />Page 3 of 5 <br />4. All floor elevations must be revised to be at least 3 feet above the highest anticipated <br />ground water table, 2 feet above the designated or designed 100-year flood elevation or 1 <br />foot above the nearest emergency overflow, whichever is higher. <br />5. The Lot Elevation Table must be revised. <br />6. Positive drainage must be provided across Lot 1, Block 1 from the existing lift station. <br />7. The bottom of the proposed infiltration basin must be lower than the inlet from the <br />stormwater pond to retain the volume to be infiltrated. <br />8. Revised notes to state tree protection fence must be hand installed and approved prior to <br />installing silt fence. <br />9. Add a second sheet for the notes and tables, turn the plan view so that it aligns with the <br />utility plans. <br />10. The grading sheets must be included with the street and utility plans. <br />11. Revise General Note 4 to read "City Engineering Department". <br />C 1.1 <br />1. Check clearance between water services under storm sewer and specify insulation if <br />needed. <br />2. Add note: "All DIP 6" and smaller shall be Class 53." <br />C 1.2 <br />1. Existing grade did not plot in profile. <br />2. Verify dark line at station 11+00 in profile. <br />3. Break lines under text. <br />4. Label shaded area on lot 12. <br />5. Extend MI-1 5 further south so that sanitary line for lot 16 can be shortened. <br />6. Connect 8" watermain to watermain under 166th Avenue. <br />7. Add hydrant at end of line. Add access road to hydrant. <br />C 1.3 <br />1. Show centerline profiles, existing and proposed. <br />2. Align plan view of OCS 202 to FES 201 with profile. <br />3. Revise access drive to existing lift station. Provide minimum 16 foot wide paved access <br />drives to both east and west sides of lift station with 10 foot clearance from infrastructure. <br />4. Show elevation of trail over proposed storm line between FES 201 and OCS 202. <br />5. The lift station detail does not provide positive drainage away from the structure. The slabs <br />must be raised to provide positive drainage to the street or a larger easement must be <br />provided on Lot 1, Block 1 so that drainage will flow to the north. <br />C 1.4 <br />1. Show centerline profiles, existing and proposed. <br />2. The lift station detail needs to be enlarged to show the proposed drainage matching the <br />grading plan and show where the discharge point is. <br />
The URL can be used to link to this page
Your browser does not support the video tag.