My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 02/14/2017
Ramsey
>
Public
>
Agendas
>
Council
>
2017
>
Agenda - Council - 02/14/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 3:03:25 PM
Creation date
3/1/2017 1:45:39 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
02/14/2017
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
904
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Alpine Drive — Street Improvements <br />Ramsey, Minnesota <br />NTI Project No. 16.61770.100 <br />LABORATORY TEST PROGRAM <br />Our analysis and recommendations of this report are based upon our interpretation of the standard <br />penetration test resistance determined while sampling soils, laboratory test results and experience with <br />similar soils from other sites near the project. The results of such tests are summarized on the boring <br />logs or attached laboratory test reports. <br />UTILITY LINE CONSTRUCTION <br />The native sand soils observed in soil borings were generally suitable for utility support and utility <br />backfill. Due to the encountered groundwater levels and depending on the installation depth of the <br />utilities, temporary dewatering may be required during the utility trench excavations. Stabilization of <br />the trench subgrade may be required in order to provide a stable platform for construction. <br />Stabilization could consist of a one half to one foot layer of crushed rock or sand with a maximum 5 <br />percent material passing the No. 200 sieve and 50 percent passing the No. 40 sieve. <br />In addition, as noted above, hard drilling in possible cobbles were encountered within the Alpine Drive <br />project area at select boring locations. Dependent upon the depth of utility installation, pipe bedding <br />may be required to provide a uniform bearing stratum and for protection of the utility piping when <br />bearing upon the underlying gravel laden soils. <br />The Geotechnical Engineer of Record or their designated representative should observe the project <br />excavations to determine that unsuitable materials have been properly removed and adequate bearing <br />support is provided by the exposed soils. The exposed soil at the base should be compacted to no less <br />than 95 percent standard Proctor maximum dry density (ASTM D698). Such observations and testing <br />should be performed prior to backfilling. <br />The on -site non -organic soils are anticipated to be suitable for reuse if properly moisture conditioned <br />and compacted. Replacement backfill required in utility trenches should consist of non -organic material <br />similar to the surrounding soil. All import fill should be approved by NTI or the City's representative. <br />It is especially important that trench backfill for utility construction within paved areas be thoroughly <br />compacted to minimize future pavement damage. We recommend that such soils be compacted in <br />accordance with the recommendations noted in the "Placement and Compaction of Engineered Fill" <br />section in Appendix B of this report. <br />The stability of embankments along utility excavations is dependent on soil strength, site geometry, <br />moisture content, and any surcharge load for excavated soils and equipment. We present cautionary <br />remarks concerning stability of excavation sideslopes in the "Excavation Stability" section of this report. <br />The Contractor is solely responsible for assessing the stability of and executing underground utility and <br />project excavations using safe methods. The contractor is also responsible for naming the "competent <br />individual" as per Subpart P of 29 CFR 1926.6 (Federal Register - OSHA). <br />The Geotechnical Engineer of Record or their designated representative should observe the project <br />excavations to determine that conditions are similar to those encountered in the borings, and that <br />adequate bearing support is provided by the exposed soils. <br />Page 4 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.