My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 12/01/2016
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2016
>
Agenda - Planning Commission - 12/01/2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:26:12 AM
Creation date
3/14/2017 12:22:53 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
12/01/2016
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF RAMSEY LAND USE APPLICATION <br /> TECHNICAL REVIEW FILE <br /> DATE NOVEMBER PROJECT ADDRESS EAST OF VARIOLITE STREET <br /> 16,2016 SOUTH OF 161 ST AVENUE <br /> PROJECT.TITLE ST.HILAIRE PROPERTY <br /> ESCROW# 115353 <br /> DEPARTMENT: Engineering <br /> Name: Leonard Linton <br /> TECHNICAL Phone: 763 433-9834 <br /> REVIEWER• Email: llinton@ci.ramsey.mn.us <br /> We offer the following comments regarding the Preliminary Plat Exhibits for St. Hilaire Property. <br /> The submittal consists of 15 sheets prepared by James R. Hill, Inc. dated October 7, 2016. <br /> All Sheets: <br /> 1. Each sheet must have a legend that identifies the line types and symbols used on that sheet. <br /> Cover Sheet: <br /> 1. Tum off the utility lines and structure labels in the plan view. Turn off the tree symbols. <br /> Site Information Plan Sheet C1.21: <br /> 1. Add column labels in the drainage summary table, it assumed the columns reflect existing <br /> and proposed conditions. <br /> 2. Add information for 100 year pond elevation. <br /> 3. Included scale bar on sheet. <br /> Preliminary Plat Sheet C2.10: <br /> 1. Lot 2 needs to have an area 60 feet wide and 100 feet deep outside of drainage and utility <br /> easements. <br /> 2. The lot depth dimensions must be drawn to the drainage and utility easement at the back <br /> of the lot, not the wetland boundary. <br /> 3. The drainage and utility easement between lots 8 and 9 needs to be 20 feet wide, 10 feet <br /> either side of the property line due to the storm sewer pipe and the need for access to the <br /> pond. <br /> 4. The proposed pond must be encompassed in a drainage and utility easement. <br /> 5. The easement widths must be labeled. <br /> Preliminary Erosion and Sediment Control Plan Sheet C3.10: <br /> 1. The development summary must include roof tops in the impervious calculations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.