Laserfiche WebLink
City of Ramsey <br /> Project B1610732.00 <br /> November 28, 2016 <br /> Page 3 <br /> Bulk asbestos analysis was conducted in accordance with the Environmental Protection Agency's (EPA) <br /> Method 40 CFR, Chapter 1, Part 763, Subpart F, and Appendix A(7/1/87 Edition). <br /> C.2. Lead-Based Paint <br /> Testing of limited building components for lead-based paint was accomplished utilizing a Niton XL X-Ray <br /> Fluorescence (XRF) field portable analyzer, Model No. XLP303A-Serial No. 22287, equipped with a 40- <br /> milocurie CD-109 source -Serial No.TR3277, installed on March 17, 2015. <br /> Analysis decision-making protocols were based on compliance with the United States (US) EPA and <br /> Minnesota Department of Health (MDH), which consider any x-ray fluorescence (XRF) result of 1.0 <br /> milligram per square centimeter(mg/cm2) or greater to be "lead-based paint."The following is a list of <br /> lead-based paints that were found on the limited building components tested. <br /> ■ No"lead-based paint"was detected in the surfaces tested at the time of the inspection. <br /> Refer to Table III in Appendix C,which lists the sample numbers, sample locations, component <br /> descriptions, XRF field results, and the paint condition for each sample. <br /> C.3. Miscellaneous Regulated Waste <br /> A visual inspection for miscellaneous regulated waste materials that require separate handling and <br /> disposal prior to disturbance during building demolition was also performed as part of this assessment. <br /> The following is a list of items documented at the site: <br /> C.3.a. Poly-Chlorinated Biphenyls (PCBs) <br /> ■ Light ballasts <br /> ■ Transformers <br /> C.3.b. Mercury <br /> ■ Batteries—smoke detectors, emergency lighting, exit signs and security system. <br /> ■ Electrical Systems—electrical panels, load meters, supply relays, control switches, fuses, <br /> motors, and pumps. <br /> ■ Heating—natural gas furnace, gauges, space heater controls,thermostats, and unit heater <br /> controls. <br /> ■ Lighting—fluorescent lamps, "silent"wall switches, explosion proof lighting, high-intensity <br /> discharge, neon and high-pressure sodium lamps. <br /> C.3.c. Chlorofluorocarbons (CFCs) and Hydrochlorofluorocarbons (HCFCs) <br /> ■ Fire extinguishers <br /> ■ Refrigerants—heat pumps, roof-top air conditioners and walk-in coolers. <br /> C.3.d. Hazardous Waste <br /> ■ Chemicals—antifreeze, paint cans, paint drums, polyurethane, solvents, stains, industrial <br /> lubricants, chemical sealer, presoak/wall cleaner, and foaming polish. <br /> ■ Lead—exit signs, lead-acid batteries, and security system. <br /> ■ Petroleum products—oils in miscellaneous motors and door closers, machine oil, and <br /> machine pistons. <br /> BRAUN <br /> INTERTEC <br />