Laserfiche WebLink
City of Ramsey <br /> Project B1610732.00 <br /> November 28, 2016 <br /> Page 5 <br /> E. Limitations <br /> This inspection was limited to areas available for observation via non-destructive means. In any building, <br /> the potential exists for hazardous building materials to be located inside walls, above ceilings, under <br /> floors, and other inaccessible areas. Braun Intertec cannot be held responsible for the presence of any <br /> such hidden materials. In the case of building renovation/demolition, contractors involved in the project <br /> should be made aware of this potential. If previously unidentified suspect hazardous building materials <br /> are exposed during their activities they should be sampled and analyzed for content prior to any <br /> disturbance. <br /> Note:A destructive ACM investigation is required by the MPCA prior to building renovation/demolition. <br /> It is recommended that the destructive ACM investigation is performed once the building is vacant. <br /> Note:It is assumed that pipe insulation may be present in currently inaccessible chases, wall cavities, and <br /> above hard ceilings. <br /> Note: It should also be noted that in order to maintain the integrity of the roof systems, no roofing <br /> materials were sampled. For the purpose of this report,the roofing and flashing materials are assumed <br /> to contain asbestos until proven otherwise by sampling and analysis. <br /> Note:Various electrical systems were identified during the survey.These systems were believed to be <br /> currently"charged" and active. Suspect materials are located within these electrical boxes, control <br /> panels (breaker bars, insulation, and electrical wire insulation). For the purpose of this report,all <br /> electrical systems associated in these areas assessed are to be assumed to contain asbestos until proven <br /> otherwise by sampling and analysis. <br /> In performing its services, Braun Intertec used that degree of care and skill ordinarily exercised under <br /> similar circumstances by reputable members of its profession currently practicing in the same locality. No <br /> warranty, express or implied, is made. <br /> F. Asbestos Inspector Certification <br /> I,the undersigned, do hereby certify that I am an accredited Asbestos Inspector in the State <br /> of Minnesota.A photocopy of my current asbestos inspector certificate is attached in Appendix E. <br /> Signature: Date: /Ila✓ ZB <br /> Eric W. Bieniek &nc!, <br /> Environmental Technician III <br /> Minnesota Department of Health Asbestos Inspector No: AI12781 <br /> BRAUN <br /> INTERTEC <br />