Review File: Covenant Meadows <br /> Geotechnical Reports Review <br /> Engineering Review <br /> March 22, 2017 <br /> Page 2 of 2 <br /> Boring 4 found poorly graded sand with silt to 8 feet and poorly graded sand below down to <br /> termination depth. <br /> Boring 6 found poorly graded sand with silt to 8 feet and poorly graded sand below down 14 feet <br /> with silty sand to termination depth. <br /> All of the sands encountered were in a very loose to loose condition. The report recommended <br /> over excavation, replacement and compaction of soils below utility lines. <br /> Recommendations <br /> The City requires that consideration be given to over excavation, replacement and compaction of <br /> soils be performed below all proposed pavements. The sandy lean clay encountered in boring 1 <br /> should be replaced with on-site sands so that all of the pavement subgrade is uniform. The sandy <br /> lean clay under the proposed infiltration area should be replaced with onsite sandy soils,minimally <br /> compacted to promote infiltration. <br /> If soils correction is not performed on the house pads then density tests at footing level and a report <br /> will be required with every building permit. <br /> The Tradewell report was dated February 9,2017. As noted above,2 feet of frost was encountered <br /> on the site in January when NTI performed their borings.A narrative listing the actual dates of the <br /> borings and evaluation of the suitability of the soils must be submitted for these borings. The <br /> borings list conditions changing at 12 inches which would be hard to pick out if the ground is <br /> frozen to 2 feet. The location map and narrative must be submitted for review and must include <br /> the items noted above. <br />