My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 05/09/2017
Ramsey
>
Public
>
Agendas
>
Council
>
2017
>
Agenda - Council - 05/09/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 3:32:24 PM
Creation date
5/12/2017 3:18:12 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
05/09/2017
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVIEWER: <br />DATE <br />CITY OF RAMSEY LAND USE APPLICATION <br />TECHNICAL REVIEW FILE <br />MAY 4, PROJECT ADDRESS EAST OF VARIOLITE STREET <br />2017 <br />PROJECT. TITLE WOODLANDS 4TH ADDITION <br />EscRow # 115353 <br />DEPARTMENT: Engineering <br />Name: Leonard Linton <br />TECHNICAL Phone: 763 433-9834 <br />Email: llinton@ci.ramsey.mn.us <br />SOUTH OF 161ST AVENUE <br />We offer the following comments regarding the Construction Plans for Woodlands 4th Addition. <br />The submittal consists of 23 sheets prepared by James R. Hill, Inc. dated March 3, 2017. <br />Preliminary Grading and Drainage Plan Sheet C3.30: <br />1. Revise the lowest floor elevation for lots 5 — 10 to 872.5. This is two (2) feet above the <br />100 year water level of the adjacent wetlands as required by the Lower Rum River <br />Watershed Management Organization (LRRWMO). (This comment was in the <br />preliminary plat review letter) <br />Preliminary Grading and Drainage Plan Sheet C3.31: <br />1. Show contours from the front of the houses to the back of curb. <br />Preliminary Utility Plan Sheet C4.10: <br />1. Add connect to existing watermain near station 15+50. <br />2. There is overlapping text in Rhinestone court. <br />3. All 6" watermain must be Class 53. <br />4. The connection to the existing sanitary manhole must be an inside drop. The City has <br />updated their detail for an inside drop. <br />5. Utility installation will require dewatering. The final plans must show a location for <br />discharge of the dewatering pipes. The downstream ditch must be checked for obstructions <br />prior to starting dewatering. <br />Preliminary Utility Plan Sheet C4.11: <br />1. The connection to the existing sanitary manhole must be an inside drop. The City has <br />updated their detail for an inside drop. Add invert label at this connection. <br />2. Check the cover over the services at Lot 8, Block 3 and insulate as needed. <br />3. All 6" watermain must be Class 53. <br />
The URL can be used to link to this page
Your browser does not support the video tag.