My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 06/27/2017
Ramsey
>
Public
>
Agendas
>
Council
>
2017
>
Agenda - Council - 06/27/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 3:33:55 PM
Creation date
7/11/2017 8:03:38 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
06/27/2017
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1054
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIAL PROVISIONS - SP20I6 BOOK <br />Last Revision by CO Special Provisions: 2/08/17 <br />(7) <br />Created August 20, 2015 <br />Page 35 <br />SP 0202-101 <br />Batching conditions and testing procedures similar to those expected for the proposed <br />work. <br />Submit all test results on the Strength Test Data sheet as part of the Contractor Mix Design <br />Submittal. <br />The Concrete Engineer reserves the right to request batching data representing the suitable <br />experience record submittal. <br />F.3.a(2) Conventional Trial Mixtures <br />If the Contractor does not have a suitable experience record as required in 2461.2.F.3.a(1) above, <br />establish concrete proportions from trial mixtures, utilizing an AMRL accredited laboratory in accordance <br />with the following: <br />(a) Use proportions and consistencies required for proposed work at the w/c ratios or <br />cementitious materials content that will produce a strength meeting or exceeding the <br />required 28-day compressive strength (f'c) in accordance with Table 2461-6 or 2461-7; <br />(b) Design trial mixtures to produce slump within ± 0.75 in. of maximum permitted; <br />(c) For air -entrained concrete, design trial mixtures to produce air content within ± 0.5 <br />percent of maximum allowable air content; <br />(d) For each w/c ratio or cementitious materials content, make and cure at least three test <br />cylinders for 28-day breaks in accordance with ASTM C 192. For HE concrete mixes, in <br />addition to the 28-day cylinders, make a set of three test cylinders for 48-hour breaks in <br />accordance with ASTM C 192. <br />Submit all test results for the trial mixtures, certified by the AMRL accredited laboratory, in <br />addition to the Contractor Mix Design Submittal. <br />S-32.13 Table 2461-11 of MnDOT 2461.2.F.4 shall be deleted and replaced with the following: <br />Level 1 <br />Mixes <br />Level 2 <br />Mixes <br />Table 2461-11 <br />Mix Design Adjustments Requirements <br />Type of Change or Adjustment <br />Mix Design Resubmittal <br />Requirements <br />• Cementitious Sources <br />• Admixture Sources No resubmittal required <br />• Admixture Dosage Rate <br />• Aggregate Sources <br />• Aggregate Proportions o Resubmittal of Mix Design <br />• Any cementitious or SCM proportion (< 15% max <br />fly ash) <br />• Any cementitious or SCM proportion (> 15% max Resubmittal in accordance with <br />fly ash) 2461.2.F.3.a <br />• Admixture Dosage Rate No resubmittal required <br />• Cement or SCM sources <br />• Aggregate Source, no change in Aggregate Class <br />• < 5% in any cementitious or SCM proportion* Resubmittal of Mix Design <br />• < 10% in Aggregate Proportions <br />• Aggregate source and Class of Coarse Aggregate <br />• > 5% in any cementitious or SCM proportion Resubmittal in accordance with <br />• > 10% Aggregate Proportions 2461.2.F.3.a <br />• Admixture Sources <br />
The URL can be used to link to this page
Your browser does not support the video tag.