My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 06/13/2017
Ramsey
>
Public
>
Agendas
>
Council
>
2017
>
Agenda - Council - 06/13/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 3:33:27 PM
Creation date
8/16/2017 2:03:39 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
06/13/2017
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DATE <br />CITY OF RAMSEY LAND USE APPLICATION <br />TECHNICAL REVIEW FILE <br />JUNE 9, PROJECT ADDRESS EAST OF NOWTHEN <br />2017 BOULEVARD, NORTH OF <br />TROTT BROOK <br />PROJECT. TITLE TROTT BROOK HALL ADDITION <br />EscRow # 115469 <br />DEPARTMENT: Engineering <br />Name: Leonard Linton <br />TECHNICAL Phone: 763 433-9834 <br />Email: llinton@ci.ramsey.mn.us <br />REVIEWER: <br />The Engineering Department offers the following comments regarding the Preliminary Plat and <br />Site plans for the proposed building expansion for Trott Brook Hall. The submittal consists of 9 <br />sheets prepared by Plowe Engineering, Inc. and 1 sheet prepared by E.G. Rud & Sons, Inc. Both <br />sets were dated May 22, 2017. The italicized comments were in our letter dated May 1, 2017 and <br />have not been addressed. <br />General comments: <br />1. A legend must be shown on all sheets. All symbols used on that sheet must be added to <br />the legend for the sheet A scale must be shown on all sheets. <br />2. Class 5 shall meet the Ramsey modified gradation. This gradation must be included in the <br />details. <br />3. Plan readability —Proposed storm sewer lines and symbols must be the most prominent on <br />the storm sewer sheets. Proposed curb lines, sidewalks and pedestrian ramps must be the <br />most prominent lines on the street sheets. All other lines on the sheet must be screened so <br />the lines and symbols for proposed features standout. Items shown as removed on the <br />removals sheet must not appear on the site plan or grading plan. This includes the symbols <br />in the legends which must match the plan view in size, pattern, weight, and color. <br />4. Underlying lines must be broken where they are under text enhance readability. <br />Underlying text must be moved so there is not text on text. <br />5. Each pedestrian ramp requires a specific detail with walk/ trail width, ramp slope, landing <br />pad slope, spot elevations and number of truncated domes. <br />
The URL can be used to link to this page
Your browser does not support the video tag.