Laserfiche WebLink
4. Notation of coordination requirements. <br />5. Notation of dimensions established by field measurement. <br />6. Sheet Size: Except for templates, patterns and similar full-size Drawings, submit Shop Drawings on sheets <br />at least 8-1/2 inches by 11 inches but no larger than 24 inches by 36 inches. <br />7. Do not use Shop Drawings without an appropriate stamp indicating action taken. <br />3.05 PRODUCT DATA <br />A. Collect Product Data into a single submittal for each element of construction or system. Product Data includes <br />printed information, such as manufacturer's installation instructions, catalog cuts, standard color charts, <br />standard wiring diagrams, applicable certifications and performance curves. Mark each copy to show <br />applicable choices and options. Where printed Product Data includes information on several products that are <br />not required, mark copies to indicate the applicable information. <br />3.06 SAMPLES <br />A. Submit full-size, fully fabricated Samples cured and finished when specified and physically identical with the <br />material or product proposed. Samples include partial sections of manufactured or fabricated components, <br />cuts or containers of materials, color range sets, and swatches showing color, texture, and pattern. Mount or <br />display Samples in the manner to facilitate review of qualities indicated. <br />3.07 QUALITY ASSURANCE AND QUALITY CONTROL SUBMITTALS <br />A. Submit quality assurance and quality control submittals, including design data, certifications, manufacturer's <br />instructions, manufacturer's field reports, materials test results, field testing and inspection reports, and other <br />quality -control submittals as required under other Sections of the Specifications. <br />B. Certifications: Where other Sections of the Specifications require certification that a product, material, or <br />installation complies with specified requirements, submit a certification from the manufacturer or responsible <br />engineer certifying compliance with specified requirements. <br />C. Calculations: When required in the technical specification, calculations shall be prepared and signed by a <br />Professional Engineer registered in the State of Minnesota. <br />3.08 ENGINEER/ARCHITECT'S ACTION <br />A. Except for submittals for the record, or for information where action and return is not required, Engineer will <br />review each submittal, mark to indicate action taken, and return within the time frame specified in Paragraph <br />3.01.A.3. <br />1. Compliance with specified characteristics is the Contractor's responsibility. <br />B. Action Stamp: Engineer will stamp each submittal with a uniform, action stamp. Engineer will mark the stamp <br />appropriately to indicate the action taken, as follows: <br />1. "Reviewed": the Work covered by the submittal may proceed provided it complies with requirements of <br />the Contract Documents. Final payment depends on that compliance. <br />2. "Reviewed with Comments": the Work covered by the submittal may proceed provided it complies with <br />notations or corrections on the submittal and requirements of the Contract Documents. Final payment <br />depends on that compliance. <br />3. "Revise and Resubmit" or "Rejected": do not proceed with Work covered by the submittal, including <br />purchasing, fabrication, delivery, or other activity. Revise or prepare a new submittal according to the <br />notations and resubmit without delay. Repeat if necessary to obtain different action mark. <br />Division 1—General Requirements <br />DV1-3 <br />