GENERAL NOTES: <br />1. SANITARY SEWER SERVICES SHALL BE 4" PVC SDR 26 <br />UNLESS OTHERWISE NOTED. <br />2. WATER SERVICES SHALL BE 1" DIA. TYPE K COPPER WITH <br />7.5' MINIMUM COVER. <br />3. SANITARY SEWER SERVICE WYES ARE STATIONED FROM THE <br />DOWN STREAM MANHOLE. <br />4. SANITARY SEWER INVERTS ARE SHOWN AT THE CURB STOP <br />AND AT THE RISER PIPE INSIDE THE BUILDING (FOR VILLA <br />UNITS). <br />5. SANITARY SEWER & WATER SERVICES SHALL BE <br />CONSTRUCTED TO THE R/W WHERE THERE IS NO SIDEWALK, <br />AND 10' BEYOND THE R/W WHERE THERE IS SIDEWALK. <br />LEGEND <br />SANITARY MANHOLE <br />FIRE HYDRANT <br />GATE VALVE <br />CATCH BASIN <br />FLARED END SECTION <br />STORM MANHOLE <br />SERVICE <br />WATERMAIN <br />SANITARY SEWER <br />FORCEMAIN <br />STORM SEWER <br />PROPERTY LINE <br />SETBACK LINE <br />CURB <br />CONCRETE SURFACE <br />INSULATION <br />EXISTING <br />SO <br />HYD <br />GV <br />or <br />O <br />STMH <br />SRV <br />birrra <br />PROPOSED <br />• <br />N <br />ore <br />A <br />• <br />> 3 <br />FM FM <br />>> >� <br />PLAN PROFILE <br />