My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 10/08/2019
Ramsey
>
Public
>
Agendas
>
Council
>
2019
>
Agenda - Council - 10/08/2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 2:34:30 PM
Creation date
10/9/2019 8:41:43 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
10/08/2019
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
548
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
contaminant sources that must be inventoried in DWSMAs vary according to the aquifer vulnerability <br />classification. For this Plan, the potential contaminant source types inventoried during the PCSI were those <br />required by the M DH for areas in which aquifer vulnerability is classified as Moderate. <br />As shown in Table C-2, information on potential contaminant source locations was obtained from the <br />following sources: Minnesota Department of Health (MDH), Minnesota Department of Natural Resources <br />(MDNR), Minnesota Department of Public Safety (DPS), Minnesota Geological Survey (MGS), Minnesota <br />Office of Pipeline Safety (MnOPS), Minnesota Pollution Control Agency (MPCA), Metropolitan Council, <br />Minnesota Geospatial Information Office (MGIO), Minnesota Department of Transportation (MnDOT), and <br />U.S. Environmental Protection Agency (USEPA) databases. Information from the various sources was <br />compared to identify overlaps/duplications. <br />As part of the PCSI work, all identified potential contaminant source locations within the DWSMAs were <br />verified to the extent possible with available information. As part of location verification, any inaccurate <br />locations identified during the PCSI (i.e., any potential contaminant source entities that appeared to map <br />on the wrong property parcel) were corrected to the extent possible based on available information. For <br />future updates of this Plan, the City will access available data sources and maintain as accurate and up to <br />date a potential contaminant source database as possible in its wellhead protection file. <br />The City maintains current records of the conditions around the municipal water supply wells. Water <br />system operators check the area around each well routinely and report any conditions of concern. A <br />potential contaminant source inventory for the Inner Wellhead Management Zone (IWMZ) around each of <br />the municipal supply wells was completed on June 12, 2019. Copies of the IWMZ inventory reports are <br />presented in Attachment C-1. <br />Properties identified as potential sources of contamination during the PCSI are listed in Table C-3 through <br />Table C-8 as follows: <br />• Wells — Table C-3 <br />• Potential Class V wells — Table C-4 <br />• Storage tanks and LUST sites — Table C-5 <br />• Chemical storage sites — Table C-6 <br />• Spill locations — Table C-7 <br />• Potential contaminant site Locations — Table C-8 <br />Results of this inventory indicate the presence of several potential contaminant source properties within <br />the DWSMAs. Locations of potential contaminant sources are shown on Figures C-5 through C-10 as <br />follows: <br />• Well locations — Figure C-5 <br />• Potential Class V Well locations — Figure C-6 <br />• Storage tank and LUST sites — Figure C-7 <br />• Chemical storage sites — Figure C-8 <br />• Spill locations — Figure C-9 <br />• Potential contaminant site locations — Figure C-10 <br />These potential contaminant sources have been considered in the development of the management <br />strategies for the DWSMA. <br />C-3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.