Appendix F - Capacity Analysis Backup <br />Generated with <br />PTV <br />Version 2020 (SP 0-3) <br />VISTRO <br />Wiz:) Spaek <br />SOLUTIONS <br />Intersection Settings <br />Priority Scheme <br />Stop <br />Stop <br />Flared Lane <br />Storage Area [veh] <br />Two -Stage Gap Acceptance <br />No <br />No <br />Number of Storage Spaces in Median <br />Movement, Approach, & Intersection Results <br />V/C, Movement V/C Ratio <br />0.00 <br />0.01 <br />0.02 <br />0.34 <br />0.01 <br />0.02 <br />d_M, Delay for Movement [s/veh] <br />10.67 <br />12.53 <br />8.40 <br />11.36 <br />9.62 <br />8.46 <br />Movement LOS <br />B <br />B <br />A <br />B <br />A <br />A <br />95th-Percentile Queue Length [veh/In] <br />0.01 <br />0.04 <br />0.06 <br />1.54 <br />0.04 <br />0.05 <br />95th-Percentile Queue Length [ft/In] <br />0.35 <br />I 0.94 <br />I <br />I 1.56 <br />38.50 <br />I <br />I 1.06 <br />I 1.15 <br />d A, Approach Delay [s/veh] <br />9.42 <br />11.16 <br />Approach LOS <br />A <br />B <br />d_I, Intersection Delay [s/veh] <br />5.20 <br />Intersection LOS <br />B <br />Scenario 5: 5 2040 AM No -Build <br />F75 <br />