GENERAL REQUIREMENTS <br />101073519 <br />of any structure or building on any private or public property <br />by placing thereon any marking, carving or graffiti. <br />It shall be the responsibility of the owner to restore said <br />surface to an approved state of maintenance and repair. <br />SECTION 303 <br />SWIMMING POOLS, SPAS AND HOT TUBS <br />303.1 Swimming pools. Swimming pools shall be main- <br />tained in a clean and sanitary condition, and in good repair. <br />303.2 Enclosures. Private swimming pools, hot tubs and <br />spas, containing water more than 24 inches (610 mm) in <br />depth shall be completely surrounded by a fence or barrier <br />not less than 48 inches (1219 mm) in height above the <br />finished ground level measured on the side of the barrier <br />away from the pool. Gates and doors in such barriers shall be <br />self -closing and self -latching. Where the self -latching device <br />is less than 54 inches (1372 mm) above the bottom of the <br />gate, the release mechanism shall be located on the pool side <br />of the gate. Self -closing and self -latching gates shall be <br />maintained such that the gate will positively close and latch <br />when released from an open position of 6 inches (152 mm) <br />from the gatepost. An existing pool enclosure shall not be <br />removed, replaced or changed in a manner that reduces its <br />effectiveness as a safety barrier. <br />Exception: Spas or hot tubs with a safety cover that <br />complies with ASTM F1346 shall be exempt from the <br />provisions of this section. <br />SECTION 304 <br />EXTERIOR STRUCTURE <br />304.1 General. The exterior of a structure shall be main- <br />tained in good repair, structurally sound and sanitary so as <br />not to pose a threat to the public health, safety or welfare. <br />304.1.1 Unsafe conditions. The following conditions <br />shall be determined as unsafe and shall be repaired or <br />replaced to comply with the International Building Code <br />or the International Existing Building Code as required <br />for existing buildings: <br />1. The nominal strength of any structural member is <br />exceeded by nominal loads, the load effects or the <br />required strength. <br />2. The anchorage of the floor or roof to walls or <br />columns, and of walls and columns to foundations <br />is not capable of resisting all nominal loads or <br />load effects. <br />3. Structures or components thereof that have <br />reached their limit state. <br />4. Siding and masonry joints including joints <br />between the building envelope and the perimeter <br />of windows, doors and skylights are not main- <br />tained, weather resistant or water tight. <br />5. Structural members that have evidence of deterio- <br />ration or that are not capable of safely supporting <br />all nominal loads and load effects. <br />6. Foundation systems that are not firmly supported <br />by footings, are not plumb and free from open <br />cracks and breaks, are not properly anchored or <br />are not capable of supporting all nominal loads <br />and resisting all load effects. <br />7. Exterior walls that are not anchored to supporting <br />and supported elements or are not plumb and free <br />of holes, cracks or breaks and loose or rotting <br />materials, are not properly anchored or are not <br />capable of supporting all nominal loads and resist- <br />ing all load effects. <br />8. Roofing or roofing components that have defects <br />that admit rain, roof surfaces with inadequate <br />drainage, or any portion of the roof framing that is <br />not in good repair with signs of deterioration, <br />fatigue or without proper anchorage and incapable <br />of supporting all nominal loads and resisting all <br />load effects. <br />9. Flooring and flooring components with defects <br />that affect serviceability or flooring components <br />that show signs of deterioration or fatigue, are not <br />properly anchored or are incapable of supporting <br />all nominal loads and resisting all load effects. <br />10. Veneer, cornices, belt courses, corbels, trim, wall <br />facings and similar decorative features not prop- <br />erly anchored or that are anchored with <br />connections not capable of supporting all nominal <br />loads and resisting all load effects. <br />11. Overhang extensions or projections including, but <br />not limited to, trash chutes, canopies, marquees, <br />signs, awnings, fire escapes, standpipes and <br />exhaust ducts not properly anchored or that are <br />anchored with connections not capable of <br />supporting all nominal loads and resisting all load <br />effects. <br />12. Exterior stairs, decks, porches, balconies and all <br />similar appurtenances attached thereto, including <br />guards and handrails, are not structurally sound, <br />not properly anchored or that are anchored with <br />connections not capable of supporting all nominal <br />loads and resisting all load effects. <br />13. Chimneys, cooling towers, smokestacks and simi- <br />lar appurtenances not structurally sound or not <br />properly anchored, or that are anchored with <br />connections not capable of supporting all nominal <br />loads and resisting all load effects. <br />Exceptions: <br />1. Where substantiated otherwise by an approved <br />method. <br />2. Demolition of unsafe conditions shall be <br />permitted where approved by the code official. <br />304.2 Protective treatment. Exterior surfaces, including but <br />not limited to, doors, door and window frames, cornices, <br />porches, trim, balconies, decks and fences, shall be main- <br />tained in good condition. Exterior wood surfaces, other than <br />decay -resistant woods, shall be protected from the elements <br />and decay by painting or other protective covering or treat- <br />3-2 <br />INTERNATIONAL CODE COUNCIL® <br />2021 INTERNATIONAL PROPERTY MAINTENANCE CODE° <br />Copyright © 2020 ICC. ALL RIGHTS RESERVED. Accessed by Jesse Szykulski (jszykulski@cityoframsey.com), (City of Minnetrista) Order Number #101073519 on Apr 19, 2021 12:45 PM (PDT) pursuant to License <br />Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED <br />REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. <br />