Laserfiche WebLink
GENERAL REQUIREMENTS <br />101073519 <br />304.18.2 Windows. Operable windows located in whole <br />or in part within 6 feet (1828 mm) above ground level or a <br />walking surface below that provide access to a dwelling <br />unit, rooming unit or housekeeping unit that is rented, <br />leased or let shall be equipped with a window sash lock- <br />ing device. <br />304.18.3 Basement hatchways. Basement hatchways <br />that provide access to a dwelling unit, rooming unit or <br />housekeeping unit that is rented, leased or let shall be <br />equipped with devices that secure the units from unautho- <br />rized entry. <br />304.19 Gates. Exterior gates, gate assemblies, operator <br />systems if provided, and hardware shall be maintained in <br />good condition. Latches at all entrances shall tightly secure <br />the gates. <br />SECTION 305 <br />INTERIOR STRUCTURE <br />305.1 General. The interior of a structure and equipment <br />therein shall be maintained in good repair, structurally sound <br />and in a sanitary condition. Occupants shall keep that part of <br />the structure that they occupy or control in a clean and sani- <br />tary condition. Every owner of a structure containing a <br />rooming house, housekeeping units, a hotel, a dormitory, two <br />or more dwelling units or two or more nonresidential occu- <br />pancies, shall maintain, in a clean and sanitary condition, the <br />shared or public areas of the structure and exterior property. <br />305.1.1 Unsafe conditions. The following conditions <br />shall be determined as unsafe and shall be repaired or <br />replaced to comply with the International Building Code <br />or the International Existing Building Code as required <br />for existing buildings: <br />1. The nominal strength of any structural member is <br />exceeded by nominal loads, the load effects or the <br />required strength. <br />2. The anchorage of the floor or roof to walls or <br />columns, and of walls and columns to foundations <br />is not capable of resisting all nominal loads or <br />load effects. <br />3. Structures or components thereof that have <br />reached their limit state. <br />4. Structural members are incapable of supporting <br />nominal loads and load effects. <br />5. Stairs, landings, balconies and all similar walking <br />surfaces, including guards and handrails, are not <br />structurally sound, not properly anchored or are <br />anchored with connections not capable of <br />supporting all nominal loads and resisting all load <br />effects. <br />6. Foundation systems that are not firmly supported <br />by footings are not plumb and free from open <br />cracks and breaks, are not properly anchored or <br />are not capable of supporting all nominal loads <br />and resisting all load effects. <br />Exceptions: <br />1. Where substantiated otherwise by an approved <br />method. <br />2. Demolition of unsafe conditions shall be <br />permitted where approved by the code official. <br />305.2 Structural members. Structural members shall be <br />maintained structurally sound, and be capable of supporting <br />the imposed loads. <br />305.3 Interior surfaces. Interior surfaces, including <br />windows and doors, shall be maintained in good, clean and <br />sanitary condition. Peeling, chipping, flaking or abraded <br />paint shall be repaired, removed or covered. Cracked or <br />loose plaster, decayed wood and other defective surface <br />conditions shall be corrected. <br />305.4 Stairs and walking surfaces. Every stair, ramp, land- <br />ing, balcony, porch, deck or other walking surface shall be <br />maintained in sound condition and good repair. <br />305.5 Handrails and guards. Every handrail and guard <br />shall be firmly fastened and capable of supporting normally <br />imposed loads and shall be maintained in good condition. <br />305.6 Interior doors. Every interior door shall fit reason- <br />ably well within its frame and shall be capable of being <br />opened and closed by being properly and securely attached <br />to jambs, headers or tracks as intended by the manufacturer <br />of the attachment hardware. <br />SECTION 306 <br />COMPONENT SERVICEABILITY <br />306.1 General. The components of a structure and equip- <br />ment therein shall be maintained in good repair, structurally <br />sound and in a sanitary condition. <br />306.1.1 Unsafe conditions. Where any of the following <br />conditions cause the component or system to be beyond <br />its limit state, the component or system shall be deter- <br />mined as unsafe and shall be repaired or replaced to <br />comply with the International Building Code or the Inter- <br />national Existing Building Code as required for existing <br />buildings: <br />1. Soils that have been subjected to any of the <br />following conditions: <br />1.1. Collapse of footing or foundation system. <br />1.2. Damage to footing, foundation, concrete <br />or other structural element due to soil <br />expansion. <br />1.3. Adverse effects to the design strength of <br />footing, foundation, concrete or other <br />structural element due to a chemical reac- <br />tion from the soil. <br />1.4. Inadequate soil as determined by a <br />geotechnical investigation. <br />1.5. Where the allowable bearing capacity of <br />the soil is in doubt. <br />3-4 <br />INTERNATIONAL CODE COUNCIL® <br />2021 INTERNATIONAL PROPERTY MAINTENANCE CODE° <br />Copyright © 2020 ICC. ALL RIGHTS RESERVED. Accessed by Jesse Szykulski (jszykulski@cityoframsey.com), (City of Minnetrista) Order Number #101073519 on Apr 19, 2021 12:45 PM (PDT) pursuant to License <br />Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED <br />REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. <br />