Laserfiche WebLink
July 21, 2005 <br />Ramscy Town Center 8th Addition Final Plat <br />Page 3 of 3 <br /> <br />· Provide valves on the north and south sides of Bunker Lake Blvd. Provide a valve <br /> mid block on 147th Terrace. <br /> <br />Page 33 <br /> <br />These plans assume the utilities south of Bunker will be in-place prior to <br />construction. If this will not be the case then these plans must include caps to be <br />rmnoved by others. <br />The 15" sanitary sewer from San Mit 33 to the stub must be laid at 0.15%. <br />A hydrant must be provided at the end of the stub for the future well. The hydrant <br />will be removed when the well is connected. <br />Note for Sanitary Sewer STA 20+85 change pipe material to "PVC". <br /> <br />Page 34 <br /> <br />The storm sewer lines shown as crossing do not match the sizes in the storm <br />plans. <br /> <br />Page 38 <br /> · The storm sewer crossing near Sta 2+60 must be insulated. <br /> <br />Page 39 <br /> <br />Provide detail of proposed curb ramp overlaid on Ramsey standard detail and <br />submitted for approval. <br />A path is required along the west property line as previously discussed. Sidewalk <br />connections must be provided between Lots 1 & 2, Block 5 and Lots 4 & 5, <br />Block 5 to the Path. <br />A sidewalk connection should be anticipated between lots 2&3, Block 2 to the <br />east property line and the 'future MSA Street. <br /> <br />Please incorporate these comments with our previous comments in the revised plans. <br /> <br /> <br />