My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 06/14/2022
Ramsey
>
Public
>
Agendas
>
Council
>
2022
>
Agenda - Council - 06/14/2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/14/2025 2:32:40 PM
Creation date
6/28/2022 9:17:14 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
06/14/2022
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
695
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. Layout and Condition of Interior Partitions/Materials <br /> a. Interior walls should be repainted. <br /> b. Interior ceilings are showing signs of water staining and should be repainted. <br /> c. Basement walls should be repainted. <br /> d. Carpeting is worn and should be replaced. <br /> 5. Exterior Construction <br /> a. Exterior wood siding is separating from structure allowing for water intrusion which is contrary to code. <br /> b. Wood siding should be repaired/repainted. <br /> c. Windows are failing allowing for water intrusion which is contrary to code. <br /> d. Roofing material is failing allowing for water intrusion which is contrary to code. <br /> DESCRIPTION OF CODE DEFICIENCIES <br /> 1. Code compliant accessible parking should be created. <br /> 2. Code compliant access into the building should be created. <br /> 3. The restroom should be modified to comply with accessibility code. <br /> 4. Staff break room should be modified to comply with accessibility code. <br /> 5. Electrical wiring should be reinstalled per code. <br /> 6. The lighting system should be modified to comply with code. <br /> 7. The HVAC system should be replaced to comply with code. <br /> 8. Thresholds should be modified to comply with code for maximum height. <br /> 9. Install code compliant building smoke detector system. <br /> 10. Install code compliant emergency lighting system. <br /> 11. A code required emergency notification system should be installed. <br /> 12. A code required building sprinkler system should be installed. <br /> 13. Stairs should be modified to comply with code. <br /> 14. Exterior wood siding should be repaired/replaced to prevent water intrusion per code. <br /> 15. Failed windows should be replaced to prevent water intrusion per code. <br /> 16. Failed roofing material should be replaced to prevent water intrusion per code. <br /> OVERVIEW OF DEFICIENCIES <br /> This building was used as the office for an auto repair business. The Thresholds should be modified to comply with code for <br /> maximum height. The staff break room should be modified to comply with accessibility code. The electrical wiring should be <br /> replaced to comply with code. The lighting system should be modified to comply with code. The HVAC system should be <br /> replaced to comply with code. The interior walls and ceiling should be repainted. The carpeting should be replaced. A code <br /> required emergency notification system should be installed. A code required building sprinkler system should be installed. <br /> The stairs should be modified to comply with code. The exterior wood siding should be repaired to prevent water intrusion per <br /> code. Windows are failing allowing for water intrusion which is contrary to code. Roofing material is failing allowing for water <br /> intrusion which is contrary to code. <br /> ENERGY CODE DEFICIENCIES <br /> In addition to the building code deficiencies listed above,the existing building does not comply with the current energy code. <br /> These deficiencies are not included in the estimated costs to correct code deficiencies and are not considered in determining <br /> whether the building is substandard. <br /> NI:\22Projr220640\300 Design\Reports\6336 HWY 10 NW-JAC Auto\Building Reports\Al -6336 Hwy 10 NVv Office Building Report Redevelopment <br /> District.docx <br /> Tungsten TIF District Page 2 of 2 Building Report <br /> LHB Project No.220640.00 Parcel Al—6336 Hwy 10 NW,Ramsey,MN 55303 <br />
The URL can be used to link to this page
Your browser does not support the video tag.