Acchma <br />Irrigation Systems <br />C53500 Installation Checklist <br />Site Installation <br />fl Sensors are installed in each mIcroclimate of the site <br />O Each sensor is be watered by a single host zone <br />O 'Each sensor is Installed in healthy turf and free frorri runoff <br />O Sensors are buried at 3 inch depth +1.1 inch_ Use stiff wire probe or ice pick to fund the sensor body <br />O Mew sites are wired with sheathed 2-conductor cable of at least 14 Gauge diameter <br />▪ All wire connections are protected by closed grease caps <br />O Wiring inside grease caps is secured by lightly fastened wire nuts_ Don't open to inspect - ask <br />O Wires in valve boxes are orderly and easily discernable as to ...vhat they conlrol <br />Device Configuration (at the Controller or from Irrigation Manageri <br />Li inspect the mill -oiler to see that it is clean and not damaged in shipping or by mishandling during <br />installation <br />in Create and name watering restrictions In accordance with area and site requirements <br />u install water sources, master valves and pumps and name them <br />O install sensors and na.rre them <br />O install flow meters and name them <br />in Assign each flow meter a water source <br />O Set pipe diameter or custom setlings for each flow meter <br />O install any remaining devices and name them <br />O Install zones and name them_ These can be reordered at any lirne <br />O Assign a Host Zone to each sensor <br />Zone Checklist <br />LJ Sensor zones are Identified and programmed as per site specifications <br />O Dependent zones are assigned to sensor zones according to the rricroclimale <br />O Dependent zones are set to reasonable tracking ratios <br />O Time Lanes have reasonable run times and frequencies <br />O Each Lone should be assigned to the proper water source <br />in All Lanes are assigned to Hite appropriate watering restriction <br />O All zones water when manually activated <br />O Water distribution patterns assure efficient coverage (head to head coverage) <br />O NIozzle types (precipitation rates) are consistent throughout each Lone <br />O Heads are clean with full spray patterns <br />O Heads are adjusted to avoid sidewalks and parking lots <br />O If a pressure meter is installed. verify that pressure readings are reasonable <br />O Set flow rates for each zone (as determined from flow meter readIngs or as specified if flow meter is not <br />present) <br />Sensor Checklist <br />Verify each sensor reads reasonable moisture, temperature and EC levels <br />LJ Identify Field Capacity and Managed Allowable Depletion levels for each sensor <br />▪ Program proper threshold settings for each sensor <br />Final Check <br />LJ Run the "Configuration Checkfrom the diagnosbc screen in Irrigation Manager and resolve concerns <br />▪ Successfully run the "System Test' from the diagnostic screen in Irrigation Manager <br />▪ Verify remote connection is working {Telephone. Ethernet, or Radio) <br />O Verify 'Voice Access" is working (where installed) <br />O install the Actlima Email Reporting application and verify it is working (where desired) <br />O Notify site maintenance personnel of site connection information <br />Create a site map with zone names and sensor locations <br />11 File an 'Initial Configuration' reference document using the "Print configuration" option in inigation Manager <br />• Create a configuration backup using "Ex.00rl. Configuration" in Irrigation Manager <br />9 I Page <br />