Laserfiche WebLink
Th~ gross, surface area of a ground sign shall ngt exceed one hundred (100) <br />square feet for each exposed face nor exceed an aggregate gross sub-ace area <br />of two hundred square feet. <br /> <br />e. A ground sign shall not ~project higher than ten (10) feet, as measured from <br /> based of sign or grade of the nearest adjacent roadway, whichever is higher· <br /> <br />9.12.11 Planned Unit Developments <br /> <br /> Subdivision 1. The developer shall be ~equked to submit a sig-~ plan for <br /> approval, drawn to scale with elevations. The sign plan shall include but not be limited to the <br /> <br />· following Information: number of signs, type of signs, sign sizes, type of construction m~terials, <br /> and sign messages. <br /> <br />'9.12.12 Construction Specifications <br /> <br /> Subdivision 1. All signs permitted by .this Section in excess of sixteen (16) <br /> square feet shall be painted, lettered, or faced to the workmanship standards and best commercial <br /> practices of companies normally engaged in the business of providing commercial slgns, using <br /> materials designed and marketed specifically for use on outdoor signs. <br /> <br /> Subd. 2. In addition to complying with the provisions 6f this ordinance, ail signs <br /> shall be constructed in accordance with the applicable provisions of the 1991 Edition of the <br /> Uni~qrm. Sign Code and State Electrical Code and as subsequently ameeded. <br /> <br /> Subd. 3. All signs shall be located in such a way that they maintain horizontal <br /> and yerfical clearance of all electrical power lines and communication lines. <br /> <br /> SubcL 4. All s/gns and their s~pporting structures ~hall maintain clearance and <br />don-interference with all'surface and underground fac/lities and conduits for water, sewage, gas, <br />electricity, or communications equipment or lines. In addition, the placement of al1 signs and <br />their supporting structures shall not interfere with natural or artificial drainage or surface or <br />underground water. <br /> <br /> Subd. 5. All signs, except those attached flat against the wall ora building shall <br />be constructed to Withstand minimum wind loads as follows: <br /> <br />. a. Solid Signs. Thirty (30) pounds per square foot per'face of the sign.- <br /> <br />Open Signs. Thirty-six (36) pounds per square foot of the total face area of <br />the letters and other sign surfaces, or ten (10) pounds per Square foot of the <br />gros~ surface area of the sig, n, whichever is greater. <br /> <br />9A2.13 Non-conforming Si~s <br /> <br />-317- <br /> <br /> <br />