- 14 - <br /> <br />150.01.4F FINAL TREATMENT AND DISPOSAL - STANDARD SYSTEM <br /> <br />Final treatment and disposal of all sewage tank effluent shall be by means of <br />soil treatment and disposal. <br /> <br />Subd. I SIZING <br /> <br /> 1. The required soil treatment area shall be determined by number of <br />bedrooms for dwellings and definition of '~aterusage" for other <br />establishments. <br /> <br /> 2. The minimum soil treatment area required for any dwelling shall <br />provide for at least two (2) bedrooms. <br /> <br /> 3. The minimum soil treatment area required for multiple residential <br />units shall consist of the sum of the areas required for each individual unit. <br /> <br /> 4. Trench and bed size shall be at least as large as set forth in <br />Table II. <br /> <br />Table II <br /> <br />Percolation Per gallon <br />rate in of waste <br />minutes per day <br />per inch (c) <br /> <br />Beds <br /> <br />Required Soil Treatment Area in Square Feet <br />Per bedroom (a) (b) <br /> Trenches <br />Depth of filter material below <br /> distribution pipe (c) in inches <br /> <br />Faster than <br /> 1/2 (d) <br />1/2 to 5 (e) <br />6 to 15 <br />16 to 30 <br />31 to 45 <br />46 to 60 <br />Slower than <br /> 60 <br /> <br />6 12 18 24 <br /> <br />Special Soil Treatment Required. See Section <br />0.83 170 170 135 115 105 <br />1.27 255 255 205 170 155 <br />1.67 335 335 270 225 205 <br />2.00 400 400 320 265 240 <br />2.20 440 440 355 290 265 <br />Unsuitable for On-Site System <br /> <br />be <br /> <br />de <br /> <br />Table II is based on a sewage flow of two hundred (200) <br />gallons per day per bedroom and shall be used as the basis <br />for sizing household systems. <br />In every case, sufficient area shall be provided for at least <br />two (2) bedrooms in dwellings. <br />For systems other than household systems, the required <br />treatment area shall be based upon gallons of waste per day. <br />The required treatment area may be reduced, for trenches <br />only, by the following percentages: Twenty per cent (20%) <br />for twelve (12) inches of filter materials below the <br />distribution pipe; thirty-four per cent (34%) for eighteen <br />(18) inches; and forty per cent (40%) for twenty-four (24) <br />inches. The filter material shall completely encase the <br />disposal pipes to a depth of at least two (2) inches. <br />Soil is unsuitable for standard system if percolation rate is <br /> <br /> <br />