Laserfiche WebLink
EXISTING TOPOGRAPHIC SYMBOLS <br />SURVEY SYMBOLS <br />EXISTING PRIVATE UTILITY LINES <br />M ACCESS GRATE <br />El AIR CONDITION UNIT <br />® ANTENNA <br />AUTO SPRINKLER CONNECTION <br />BARRICADE PERMANENT <br />• BASKETBALL POST <br />▪ BENCH <br />▪ BIRD FEEDER <br />O BOLLARD <br />O BUSH <br />E CATCH BASIN RECTANGULAR CASTING <br />® CATCH BASIN CIRCULAR CASTING <br />CURB STOP <br />m CLEAN OUT <br />CULVERT END <br />O DRINKING FOUNTAIN <br />• DOWN SPOUT <br />C9 ELECTRIC CAR CHARGE STATION <br />O FILL PIPE <br />FIRE HYDRANT <br />ocuT <br />Cr-- FLAG POLE <br />C— FLARED END/APRON <br />O FUEL PUMP <br />CD GRILL <br />GUY WIRE ANCHOR <br />E HANDHOLE <br />b. HANDICAP SPACE <br />• IRRIGATION SPRINKLER HEAD <br />• IRRIGATION VALVE BOX <br />cP LIFT STATION CONTROL PANEL <br />© LIFT STATION <br />E LIGHT POLE <br />MAILBOX <br />© MANHOLE -COMMUNICATION <br />QE MANHOLE -ELECTRIC <br />QQ MANHOLE -GAS <br />QQ MANHOLE -HEAT <br />QW MANHOLE -RECLAIMED WATER <br />Qs MANHOLE -SANITARY SEWER <br />QQ MANHOLE -STORM SEWER <br />QQ MANHOLE -UTILITY <br />wQ MANHOLE -WATER <br />E METER <br />DRIVE-THRU MICROPHONE <br />• PARKING METER <br />PAVEMENT MARKING <br />© PEDESTAL -COMMUNICATION <br />O PEDESTAL -ELECTRIC <br />0-1 PEDESTRIAN PUSH BUTTON <br />• PICNIC TABLE <br />�S POLE -UTILITY <br />© POST <br />E3 RAILROAD SIGNAL POLE <br />OG REGULATION STATION GAS <br />' SATELLITE DISH <br />- SIGN TRAFFIC <br />O SIGNAL CONTROL CABINET <br />• SOIL BORING <br />E:n SIREN <br />▪ TELEPHONE BOOTH <br />O TILE INLET <br />TILE OUTLET <br />® TILE RISER <br />▪ TRANSFORMER -ELECTRIC <br />• TREE -CONIFEROUS <br />TREE -DEAD <br />Q TREE -DECIDUOUS <br />FR TREE STUMP <br />C=— TRAFFIC ARM BARRIER <br />®TILE <br />• TRAFFIC SIGNAL <br />rOR TRASH CAN <br />• UTILITY MARKER <br />X VALVE <br />® VALVE POST INDICATOR <br />® VALVE VAULT <br />E VAULT <br />Ov VENT PIPE <br />®vas WATER SPIGOT <br />O WELL <br />d WETLAND DELINEATED MARKER <br />• WETLAND <br />WET WELL <br />O YARD HYDRANT <br />OE <br />PROPOSED TOPOGRAPHIC SYMBOLS <br />• CLEANOUT <br />• MANHOLE <br />• LIFT STATION <br />® STORM SEWER CIRCULAR CASTING <br />• STORM SEWER RECTANGULAR CASTING <br />Or STORM SEWER FLARED END / APRON <br />• STORM SEWER OUTLET STRUCTURE <br />• STORM SEWER OVERFLOW STRUCTURE <br />o CURB BOX <br />• FIRE HYDRANT <br />N WATER VALVE <br />• WATER REDUCER <br />▪ WATER BEND <br />FTi WATER TEE <br />▪ WATER CROSS <br />WATER SLEEVE <br />n WATER CAP / PLUG <br />RIP RAP <br />kI- <br />DRAINAGE FLOW <br />TRAFFIC SIGNS <br />• BENCHMARK LOCATION <br />0 CONTROL POINT <br />• MONUMENT FOUND <br />EXISTING TOPOGRAPHIC LINES <br />O CAST IRON MONUMENT <br />■ STONE MONUMENT <br />x <br />SURVEY LINES <br />x <br />x <br />x <br />RETAINING WALL <br />FENCE <br />FENCE -DECORATIVE <br />GUARD RAIL <br />TREE LINE <br />BUSH LINE <br />EXISTING UTILITY LINES <br />CONTROLLED ACCESS <br />BOUNDARY <br />CENTERLINE <br />EXISTING EASEMENT LINE <br />PROPOSED EASEMENT LINE <br />EXISTING LOT LINE <br />PROPOSED LOT LINE <br />EXISTING RIGHT-OF-WAY <br />PROPOSED RIGHT-OF-WAY <br />SETBACK LINE <br />SECTION LINE <br />QUARTER LINE <br />SIXTEENTH LINE <br />TEMPORARY EASEMENT <br />NM NM NM NM <br />PROPOSED UTILITY LINES <br />wR <br />wR <br />FORCEMAIN <br />SANITARY SEWER <br />SANITARY SERVICE <br />STORM SEWER <br />STORM SEWER DRAIN TILE <br />WATERMAIN <br />WATER SERVICE <br />RECLAIMED WATER <br />II <br />II <br />II <br />» » » » <br />7/ i7 74%i7744/V7L747 ,)( -7G- <br />V///////////1 <br />GRADING INFORMATION <br />FORCEMAIN <br />SANITARY SEWER <br />SANITARY SERVICE <br />STORM SEWER <br />STORM SEWER DRAIN TILE <br />WATERMAIN <br />WATER SERVICE <br />PIPE CASING <br />TRENCHLESS PIPE (PLAN VIEW) <br />TRENCHLESS PIPE (PROFILE VIEW) <br />_ 950- <br />x 953.53 <br />1:4 <br />HATCH PATTERNS <br />x STA:5+67.19 <br />980.87 <br />EXISTING CONTOUR MINOR <br />EXISTING CONTOUR MAJOR <br />PROPOSED CONTOUR MINOR <br />PROPOSED CONTOUR MAJOR <br />PROPOSED GRADING LIMITS / SLOPE LIMITS <br />PROJECT LIMITS <br />PROPOSED SPOT ELEVATION <br />RISE:RUN (SLOPE) <br />BITUMINOUS <br />CONCRETE <br />GRAVEL <br />NOTE: <br />EXISTING UTILITY INFORMATION SHOWN ON THIS PLAN HAS BEEN PROVIDED BY THE UTILITY OWNER. THE CONTRACTOR SHALL FIELD VERIFY <br />EXACT LOCATIONS PRIOR TO COMMENCING CONSTRUCTION AS REQUIRED BY STATE LAW. NOTIFY GOPHER STATE ONE CALL, 1-800-252-1166 OR <br />651-454-0002. <br />THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS UTILITY QUALITY LEVEL D UNLESS OTHERWISE NOTED. THIS UTILITY LEVEL WAS <br />DETERMINED ACCORDING TO THE GUIDELINES OF Cl/ASCE 38-22, ENTITLED "STANDARD GUIDELINE FOR INVESTIGATING AND DOCUMENTING <br />EXISTING UTILITIES". <br />OE <br />oC <br />oU <br />F F <br />OE <br />oC <br />oU <br />F F <br />c <br />6 <br />OE OE <br />oc oc . <br />ou ou <br />UTILITIES IDENTIFIED WITH A QUALITY LEVEL : <br />UNDERGROUND FIBER OPTIC <br />UNDERGROUND ELECTRIC <br />UNDERGROUND GAS <br />UNDERGROUND COMMUNICATION <br />OVERHEAD ELECTRIC <br />OVERHEAD COMMUNICATION <br />OVERHEAD UTILITY <br />LINE TYPES FOLLOW THE FORMAT: UTILITY TYPE - QUALITY LEVEL <br />EXAMPLE: GA GA UNDERGROUND GAS, QUALITY LEVEL A <br />UTILITY QUALITY LEVEL (A,B,C,D) DEFINITIONS CAN BE FOUND IN Cl/ASCE 38-22. <br />UTILITY QUALITY LEVELS: <br />QUALITY LEVEL D: PROVIDES THE MOST BASIC LEVEL OF INFORMATION. IT INVOLVES COLLECTING DATA FROM EXISTING UTILITY RECORDS. <br />RECORDS MAY INCLUDE AS -BUILT DRAWINGS, DISTRIBUTION AND SERVICES MAPS, EXISTING GEOGRAPHIC INFORMATION SYSTEM DATABASES, <br />CONSTRUCTION PLANS, ETC. <br />QUALITY LEVEL C: INVOLVES SURVEYING VISIBLE SUBSURFACE UTILITY STRUCTURES SUCH AS MANHOLES, HAND -HOLES, UTILITY VALVES AND <br />METERS, FIRE HYDRANTS, PEDESTALS AND UTILITY MARKERS, AND THEN CORRELATING THE INFORMATION WITH EXISTING UTILITY RECORDS TO <br />CREATE COMPOSITE DRAWINGS. INCLUDES QUALITY LEVEL D ACTIVITIES. <br />QUALITY LEVEL B: INVOLVES DESIGNATING THE HORIZONTAL POSITION OF SUBSURFACE UTILITIES THROUGH SURFACE DETECTION METHODS AND <br />COLLECTING THE INFORMATION THROUGH A SURVEY METHOD. INCLUDES QUALITY LEVEL C AND D TASKS. <br />QUALITY LEVEL A: PROVIDES THE HIGHEST LEVEL OF ACCURACY. IT INVOLVES LOCATING OR POTHOLING UTILITIES AS WELL AS ACTIVITIES IN <br />QUALITY LEVELS B, C, AND D. THE LOCATED FACILITY INFORMATION IS SURVEYED AND MAPPED AND THE DATA PROVIDES PRECISE PLAN AND <br />PROFILE INFORMATION. <br />ABBREVIATIONS <br />A <br />ADJ <br />ALT <br />B-B <br />BIT <br />BLDG <br />BMP <br />BR <br />BV <br />CB <br />C&G <br />CIP <br />CIPP <br />CL <br />CL. <br />CLVT <br />CMP <br />C.O. <br />COMM <br />CON <br />CSP <br />DIA <br />DIP <br />DWY <br />ELEC <br />ELEV <br />EOF <br />ER <br />ESMT <br />EX <br />FES <br />F-F <br />FF <br />F&I <br />FM <br />FO <br />F.O. <br />GRAN <br />ALGEBRAIC DIFFERENCE <br />ADJUST <br />ALTERNATE <br />BACK TO BACK <br />BITUMINOUS <br />BUILDING <br />BEST MANAGEMENT PRACTICE <br />BEGIN RADIUS <br />BUTTERFLY VALVE <br />CATCH BASIN <br />CURB AND GUTTER <br />CAST IRON PIPE <br />CURED -IN -PLACE PIPE <br />CENTER LINE <br />CLASS <br />CULVERT <br />CORRUGATED METAL PIPE <br />CHANGE ORDER <br />COMMUNICATION <br />CONCRETE <br />CORRUGATED STEEL PIPE <br />DIAMETER <br />DUCTILE IRON PIPE <br />DRIVEWAY <br />EXTERNAL CURVE DISTANCE <br />ELECTRIC <br />ELEVATION <br />EMERGENCY OVERFLOW <br />END RADIUS <br />EASEMENT <br />EXISTING <br />FLARED END SECTION <br />FACE TO FACE <br />FINISHED FLOOR <br />FURNISH AND INSTALL <br />FORCEMAIN <br />FIBER OPTIC <br />FIELD ORDER <br />GRANULAR <br />GRAV <br />GU <br />GV <br />HDPE <br />HH <br />HP <br />HWL <br />HYD <br />LO <br />LP <br />LT <br />MAX <br />MH <br />MIN <br />MR <br />NIC <br />NMC <br />N TS <br />NWL <br />OHW <br />PC <br />PCC <br />PE <br />PED <br />PERF <br />PERM <br />PI <br />PL <br />PRC <br />PT <br />PVC <br />PVMT <br />R <br />R/W <br />RCP <br />RET <br />GRAVEL <br />GUTTER <br />GATE VALVE <br />HIGH DENSITY POLYETHYLENE <br />HANDHOLE <br />HIGH POINT <br />HIGH WATER LEVEL <br />HYDRANT <br />INVERT <br />CURVE COEFFICIENT <br />LENGTH <br />LOWEST OPENING <br />LOW POINT <br />LEFT <br />MAXIMUM <br />MANHOLE <br />MINIMUM <br />MID RADIUS <br />NOT IN CONTRACT <br />NON-METALLIC CONDUIT <br />NOT TO SCALE <br />NORMAL WATER LEVEL <br />ORDINARY HIGH WATER LEVEL <br />POINT OF CURVE <br />POINT OF COMPOUND CURVE <br />PERMANENT EASEMENT <br />PEDESTRIAN, PEDESTAL <br />PERFORATED PIPE <br />PERMANENT <br />POINT OF INTERSECTION <br />PROPERTY LINE <br />POINT OF REVERSE CURVE <br />POINT OF TANGENT <br />POLYVINYL CHLORIDE PIPE <br />PAVEMENT <br />RADIUS <br />RIGHT-OF-WAY <br />REINFORCED CONCRETE PIPE <br />RETAINING <br />RSC <br />RT <br />SAN <br />SCH <br />SERV <br />SHLD <br />STA <br />STD <br />STM <br />TC <br />TE <br />TEMP <br />TNH <br />TP <br />TYP <br />VCP <br />VERT <br />VPC <br />VPI <br />VPT <br />WM <br />RIGID STEEL CONDUIT <br />RIGHT <br />SANITARY SEWER <br />SCHEDULE <br />SERVICE <br />SHOULDER <br />STATION <br />STANDARD <br />STORM SEWER <br />TOP OF CURB <br />TEMPORARY EASEMENT <br />TEMPORARY <br />TOP NUT HYDRANT <br />TOP OF PIPE <br />TYPICAL <br />VITRIFIED CLAY PIPE <br />VERTICAL <br />VERTICAL POINT OF CURVE <br />VERTICAL POINT OF INTERSECTION <br />VERTICAL POINT OF TANGENT <br />WATERMAIN <br />AC ACRES <br />CF CUBIC FEET <br />CV COMPACTED VOLUME <br />CY CUBIC YARD <br />EA EACH <br />EV EXCAVATED VOLUME <br />LB POUND <br />LF LINEAR FEET <br />LS LUMP SUM <br />LV LOOSE VOLUME <br />SF SQUARE FEET <br />SV STOCKPILE VOLUME <br />SY SQUARE YARD <br />I HEREBY CERTIFY THAT THI S PLAN, SPECIFICATION, OR REPORT WAS PREPARED <br />BY ME OR UNDER MY DIRECT SUPERVMON AND THAT I AM A DULY LICENSED <br />PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA <br />EVIN P. KIELB <br />LIC <br />0 23211 <br />DATE <br />8/20/2024 <br />BOLTON <br />& MENK <br />7533 SU N WOOD DR NW, SUITE 206 <br />RAMSEY, MN 55303 <br />Phone: (763) 433-2851 <br />Email: Ramsey@ bolton-menk.com <br />www.bolton-menk.com <br />DESIGNED ZFL <br />DRAWN TJH <br />NO <br />ISSUED FOR <br />DATE <br />CHECKED KPK <br />CITY OF RAMSEY, MINNESOTA <br />RIVERS BEND REGIONAL STORMWATER IMPROVEMENTS <br />CLIENTCP 25-01 <br />PRO1 NO <br />LEGEND <br />SHEET <br />2 <br />OF <br />12 <br />