My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Public Works Committee - 03/27/2025
Ramsey
>
Public
>
Agendas
>
Public Works Committee
>
2025
>
Agenda - Public Works Committee - 03/27/2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 2:42:53 PM
Creation date
3/27/2025 2:27:16 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Public Works Committee
Document Date
03/27/2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CEDHR CRE[K <br />Zvt.Crgy <br />TYPICAL OF <br />#1 - #3 <br />INVERTER <br />TYPICAL OF <br />#4-#6 <br />INVERTERS <br />TYPICAL OF <br />#7-#9 <br />INVERTERS <br />TYPICAL OF <br />#10 -#12 <br />INVERTERS <br />TYPICAL OF <br />#13 -#15 <br />INVERTERS <br />(N) PV INVERTER'S <br />(TOTAL QTY 15) <br />JINKO JKM580N-72HL4-BDV CPS 275/275kW V2 <br />TOTAL QTY: 8,700 MODULES RATED POWER: <br />MODULES VARY PER STRING 275000W / 275kW AC <br />MAX CURRENT OUTPUT: 198.5A <br />AT STC: PMPP =580W, VMPP = 43.88V 800V, 3PH, 3W <br />IMPP = 13.22A UL1741 CERTIFIED <br />rSTRING <br />1 <br />• <br />STRING <br />24 <br />STRING <br />1 <br />• <br />STRING <br />23 <br />STRING <br />1 <br />• <br />STRING <br />23 <br />STRING <br />1 <br />• <br />STRING <br />23 <br />STRING <br />1 <br />• <br />STRING <br />23 <br />U <br />2 <br />PV INVERTER #1 - #3 <br />24 <br />U <br />25 <br />PV MODULES <br />U <br />2 <br />24 <br />25 <br />PV MODULES <br />DC <br />AC <br />PV INVERTER #4 - #6 <br />1 2 24 <br />25 <br />PV MODULES <br />U <br />2 <br />U U <br />24 <br />25 <br />PV MODULES <br />U <br />U <br />2 <br />• <br />DC <br />• Oy <br />AC <br />(N) 800 VAC BREAKER <br />BOX (QTY 5) <br />(QTY 3) 250A ,3P <br />BREAKERS PER 800 VAC <br />COMBINER BOX. <br />BREAKER BOX #1 <br />INVERTERS #1-#3 <br />250A <br />•1 <br />250A <br />250A <br />11141 <br />(N) 800 VAC 800A <br />SWITCH BOX <br />FUSED AT 800A <br />(QTY 5) <br />Vac SWITCH BOX #1 <br />800A FUSES <br />..0" <br />UTILITY AC DISCONNECT <br />600A, 15kV, 95kV BIL GANG OPERATED SWITCH. <br />READILY ACCESSIBLE, LOCKABLE IN THE OPEN <br />POSITION AND VISIBLE OPEN FOR UTILITY USE <br />MEDIUM VOLTAGE GRID CONNEX 15KVC <br />EQUIPMENT ENCLOSURE <br />MEDIUM VOLTAGE TRANSFORMER SKID <br />4200KVA TRANSFORMER <br />12.47KV VAC PRIMARY (191A) <br />800V VAC SECONDARY (WYE) <br />2977.5A <br />BREAKER BOX #2 Vac SWITCH BOX #2 <br />INVERTERS #4-#6 <br />250A <br />PV INVERTER #7 - #9 <br />24 <br />1 <br />25 <br />PV MODULES <br />U <br />U <br />2 <br />24 <br />25 <br />PV MODULES <br />U <br />U <br />2 <br />1 2 <br />1 2 <br />DC <br />AC <br />800A FUSES <br />250A <br />250A <br />BREAKER BOX #3 <br />INVERTERS #7-#9 <br />250A <br />250A50 <br />PV INVERTER #10 - #12 <br />24 <br />1 <br />25 <br />PV MODULES <br />24 <br />25 <br />PV MODULES <br />DC <br />AC <br />250A <br />Vac SWITCH BOX #3 <br />800A FUSES <br />.448- <br />BREAKER BOX #4 Vac SWITCH BOX #4 <br />INVERTERS #10-#12 <br />PV INVERTER #13 - #15 <br />v \ <br />24 <br />25 <br />PV MODULES <br />1 2 24 <br />25 <br />PV MODULES <br />DC <br />AC <br />250A <br />1•• <br />• <br />250A <br />800A FUSES <br />250A <br />BREAKER BOX #5 Vac SWITCH BOX #5 <br />INVERTERS #13-#15 <br />250A <br />800A FUSES <br />250A <br />250A <br />111. <br />KEYED NOTES: <br />1. GRID CONNEX MV CONNECTION CABINET. INCLUDED INTEGRATED VACUUM BREAKER,VISIBLE BLADE DISCONNECT, SEL RELAY AND CUSTOMER <br />OWNED PTs,CTs AND METERING. <br />2. CPS MEDIUM VOLTAGE TRANSFORMER SKID WITH 4.2 MVA, 12.47 kV PRIMARY TO 800 Vac SECONDARY. <br />3. CPS MEDIUM VOLTAGE SKID EQUIPPED WITH (1) 40AKVA AUX TRANSFORMER,800V PRIMARY TO 277/480V SECONDARY,(1) 5KVA TRANSFORMER <br />PRIMARY TO 120/240V SECONDARY. <br />4. INDICATED CIRCUIT BREAKER SHALL BE EQUIPPED WITH AUXILIARY CONTACT TO TRIGGER MAIN PV DISCONNECT UPON OPENING OF CIRCUIT <br />BREAKER. <br />5. PROVIDE 600A, 3P DISCONNECT SIZED AS NOTED. DISCONNECT SHALL SERVE AS UTILITY PV AC DISCONNECT. <br />6. PROVIDE (3) #10 AWG CU PHASE CONDUCTORS AND #10 AWG CU GROUND IN 3/4" CONDUIT. <br />7 MOTOR ELECTRONICS ENCLOSURE IS LOCATED AT EACH MOTOR. MOTOR ELECTRONICS ENCLOSURE IS FURNISHED BY RACKING <br />MANUFACTURER. TERMINATE BOTH THE POWER AND CONTROL WIRING AT ENCLOSURE. COORDINATE WITH EQUIPMENT PROVIDER FOR MORE <br />ELECTRICAL REQUIREMENTS. <br />8. PROVIDE GROUNDING FOR SERVICE ENTRANCE EQUIPMENT PER NEC REQUIREMENTS. <br />9. A SEL 751 FEEDER PROTECTION RELAY AND SEL 735 POWER QUALITY AND REVENUE METER TO BE PROVIDED AND INTEGRATED INTO THE <br />FEDERAL PACIFIC GRID CONNEX GEAR. <br />10. INVERTERS ARE EQUIPPED WITH TOUCH -SAFE FUSE HOLDERS AND STANDARD A74, 30A DC FUSES ON THE POSITIVE SIDE ONLY. <br />11. CIRCUIT BETWEEN MOTOR ELECTRONICS ENCLOSURE AND ASSOCIATED TRACKER MOTOR FURNISHED BY EQUIPMENT SUPPLIER AND INSTALLED <br />BY ELECTRICAL CONTRACTOR. COORDINATE WITH EQUIPMENT SUPPLIER FOR MORE INFORMATION. <br />EXP CLF <br />A <br />800V 12.47KV <br />j--<(--<(3) SA <br />10kV NOM <br />8.4kV <br />MCOV <br />40KVA AUX TRANSFORMER <br />800V VAC PRIMARY <br />277/480V VAC SECONDARY <br />MeNeN <br />5KVA AUX TRANSFORMER <br />800V VAC PRIMARY <br />120/240V VAC SECONDARY <br />40A <br />20A . <br />20A <br />20A <br />20A <br />20A <br />ATI MOTOR <br />ELECTRONICS <br />ENCLOSURE <br />#1- #6 (TYP.) <br />to <br />TRACKER <br />MOTOR <br />'M1-M6' <br />2HP <br />100A PANEL BOARD <br />277/480V <br />40A MAIN BREAKER <br />TRACKER MASTER <br />POWER <br />20A <br />20A <br />20A <br />vs <br />SINGLE PHASE <br />VACCUM BREAKERS <br />15KVAC 800A <br />52 <br />0 <br />ti <br />METER <br />50 <br />27 <br />RELAY <br />08 <br />• <br />CPT <br />0 <br />R-CTs M-CTs <br />o • (( <br />/ <br />(3) VTs <br />120V SEC <br />v <br />CONTROL <br />POWER <br />0 <br />12 <br />60A PANEL BOARD <br />120/240V <br />40A MAIN BREAKER <br />CONTROLS/ AUX <br />POWER <br />ATI MOTOR <br />CONTROLLER <br />12. PROVIDE A 20A, 2-POLE BREAKER IN CONTROL PANEL BOARD FOR CIRCUITS SHOWN. <br />13. PROVIDE (2) #10 AWG CU PHASE CONDUCTORS AND #10 AWG CU GROUND IN 3/4" CONDUIT TO EACH ENCLOSURE AS SHOWN. <br />14. PROVIDE CONDUCTOR FOR EACH LEG OF DC CIRCUIT AS SHOWN. HOMERUN CABLE SHALL BE SECURELY FASTENED TO SOLAR PANEL <br />STRUCTURE WITH LISTED SUPPORT HARDWARE. BOTH POSITIVE AND NEGATIVE CONDUCTOR ARE UNGROUNDED AND SHALL BE COLOR CODED <br />IN THE FOLLOWING FASHION: <br />POSITIVE = RED <br />NEGATIVE = BLACK <br />15. CONDUCTORS SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690.31 AND ROUTED WITHIN THE RACKING SYSTEM. CONDUCTORS SHALL BE <br />INSTALLED IN A WORKMANSHIP LIKE MANNER, PROTECTED FROM SHARP METALLIC SURFACES, PROPERLY BUNDLED (WITH UV RESISTANT <br />MATERIALS) AND SECURED WITHIN THE RACKING SYSTEM. <br />16. PROVIDE #4 AWG BARE EQUIPMENT GROUNDING CONDUCTOR TO RACKING SYSTEM USING LISTED GROUNDING CONNECTOR KIT PER <br />MANUFACTURER'S REQUIREMENT. RACKING SYSTEM IS LISTED AND IDENTIFIED FOR BONDING PV MODULES. FIELD VERIFY. EQUIPMENT <br />GROUNDING CONDUCTOR SHALL BE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS IN CONDUIT WHEN CIRCUIT CONDUCTORS LEAVE THE <br />VICINITY OF THE PV ARRAY. <br />17. UPS POWER IS PROVIDED IN THE GRIDCONNEX TO THE SEL 751 AND SEL 735. <br />18. THERE IS NOT LIGHTING ON SITE <br />19. THE INVERTER SUPPORTS INDUSTRY STANDARD MODBUS R485, ETHERNET, CAN, AND AC -PLC COMMUNICATION MODES. AC -PLC <br />COMMUNICATION REQUIRES CONNECTION OF THE CPS AC -PLC KIT ASCCESORY <br />20. CCE TO PROVIDE AND INSTALL MV CONDUCTORS TO UTILITY PRIMARY METERING CABINET. CONNEXUS IS RESPONSIBLE FOR TERMINATING THE <br />MV CONDUCTORS IN THE UTILITY PRIMARY METERING CABINET <br />GENERAL NOTES: <br />12.47 KV to UTILITY EPS <br />CUSTOMER <br />OWNED EQUIPMENT <br />-3 E- <br />R <br />1 <br />UTILITY <br />OWNED EQUIPMENT <br />UTILITY PRIMARY <br />METERING <br />CABINET <br />UTILITY OWNED <br />VIPER RECLOSER <br />EXISTING UTILITY <br />12.47V DISTRIBUTION LINE <br />A EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC 2023 EDITION AND <br />ALL APPLICABLE REQUIREMENTS OF THE LOCAL ELECTRIC UTILITY COMPANY AND <br />THE LOCAL AUTHORITY HAVING JURISDICTION. <br />B FOLLOW MANUFACTURERS SUGGESTED INSTALLATION PRACTICES AND WIRING <br />SPECIFICATIONS. <br />C FIELD VERIFY DC WIREBOX PROVIDED WITH INVERTER AND FOLLOW <br />MANUFACTURER REQUIREMENTS FOR TERMINATING DC CONDUCTORS. <br />D PROVIDE DC SOURCE CONDUCTOR JUMPERS UTILIZING WIRE SIZE AND <br />CONNECTORS THAT MATCH MODULE BETWEEN MODULES IF MODULE PROVIDED <br />CONDUCTORS ARE NOT LONG ENOUGH TO CONNECT TO EACH OTHER. <br />E POWER FACTOR IS ASSUMED TO BE 1 (UNITY) <br />CEDAR CREEK ENERGY <br />3155 104TH LN NE <br />BLAINE, MN, 55449 <br />PHONE # 763-450-9763 <br />PROJECT ADDRESS <br />6501 SUNWOOD DR. NW <br />RAMSEY, MN 55303 <br />UTILITY CUSTOMER OF RECORD <br />CELF 2024 LLC <br />PROJECT DESCRIPTION <br />SYSTEM SIZE (DC) <br />5.046 MW <br />SYSTEM SIZE (AC) <br />4.125 MW <br />DC/AC RATIO <br />1.223 <br />AZIMUTH <br />90/270° <br />TILT <br />+/- 5 2° <br />MODULE TYPE <br />JINKO <br />JKM580N-72HL4-BDV <br />MODULE COUNT <br />8,700 <br />INVERTER TYPE <br />CPS SCH275KTL-DO/US 800 <br />275 kW <br />INVERTER POWER (kW) <br />275kW <br />RACKING <br />SINGLE AXIS TRACKER <br />MONITORING <br />ALSO ENERGY <br />PROJECT AREA <br />-23.04 ACRE <br />MIN./MAX. TEMP <br />-26°C / 32°C <br />OTHER NOTES <br />NO POSITION, DISTANCE, OR CLEARANCE <br />ISSUES WITH OVERHEAD ELECTRIC SERVICE <br />LINES OR OTHER UTILITIES IN RELATION TO <br />THE PV PANELS <br />24/7 UNESCORTED KEYLESS ACCESS FOR <br />THE UTILITY METERS AND UTILITY AC <br />DISCONNECT <br />REVISIONS <br /># <br />DESCRIPTION <br />BY <br />CHK'D <br />DATE <br />0 <br />IC SET <br />TB <br />MH <br />12/23/2024 <br />1 <br />2 <br />DRAWN BY : <br />TONY BRIENZA <br />PROJECT NAME & JOB #: <br />CONNEXUS LANDFILL <br />SHEET DESCRIPTION : <br />ONE LING DIAGRAM <br />SHEET SIZE: <br />36X24 <br />SPACE FOR PE STAMP : <br />I hereby certify that this plan, specification, <br />or report was prepared by me or under my <br />direct supervision and that I am a duly <br />Licensed Professional Engineer under the laws <br />of the state of %}Minnesota.'! <br />Signature. �/��L -e.�F�s•► <br />Name: Michael Herman <br />Date: 01/24/2025 License Number: 57145 <br />SHEET : <br />PV-3.O <br />
The URL can be used to link to this page
Your browser does not support the video tag.