Laserfiche WebLink
m - CEDRR <br />CREEK <br />.. <br />qq <br />CEDAR CREEK ENERGY <br />3155 104TH LN NE <br />BLAINE, MN, 55449 <br />PHONE # 763-450-9763 <br />PROJECT ADDRESS <br />OCPR <br />Orm <br />Technical Data <br />6501 SUNWOOD DR. NW <br />RAMSEY, MN 55303 <br />UTILITY CUSTOMER OF RECORD <br />Datasheet <br />Model Name <br />CPS SCH275KTL-DO/US-800-36 V2 <br />CPS SCH275KTL-DO/US-800-24 V2 <br />DC Input <br />250/275kW <br />V2, 1500Vdc <br />StringInverters <br />for <br />North <br />America <br />Max.DCinputvoltagerange 1500V <br />Operating DC input voltage range 500-1450 Vdc <br />Start-up DC input voltage / power 550 Vdc / 500 W <br />CELF 2024 LLC <br />PROJECT DESCRIPTION <br />MPPT voltage range for Pnom @ PF>0.991 900-1300 Vdc <br />SYSTEM SIZE (DC) <br />5.046 MW <br />Number of MPP trackers 12 <br />Max. PV input current (dipping point) 30 A per MPPT <br />SYSTEM SIZE (AC) <br />4.125 MW <br />Production Limits 36.5 kW/MPPT or 275 kW total output <br />Max. PV short-circuit current 600 A, 50 A per MPPT <br />DC/AC RATIO <br />1.223 <br />Number of DC inputs 36 fused inputs, 3 per MPPT 24 non -fused inputs <br />AZIMUTH <br />90/270° <br />CPSDC <br />disconnection type Load -rated DC switches <br />DC surge protection Type II <br />TILT <br />+/- 52° <br />AC Output <br />Max AC output power (selectable2) @ PF>0.99 250 kW / 275 kW <br />MODULE TYPE <br />JINKO <br />JKM580N-72HL4-BDV <br />Max. AC apparent power 275 kVA <br />Rated output voltage 800 Vac <br />MODULE COUNT <br />8,700 <br />Output voltage range3 704-880 Vac <br />INVERTER TYPE <br />CPS SCH275KTL-DO/US 800 <br />275 kW <br />Grid connection type 3-phase / PE <br />Max. AC output current @ 800 Vac 198.5 A <br />INVERTER POWER (kW) <br />275kW <br />Rated output frequency 60 Hz <br />Output frequency range3 57-63 Hz <br />RACKING <br />SINGLE AXIS TRACKER <br />Power factor >0.99 (±0.8 adjustable) <br />MONITORING <br />ALSO ENERGY <br />CurrentTRD @ rated load <3% <br />Max. OCPD rating 300 A <br />PROJECT AREA <br />—23.04 ACRE <br />AC surge protection Type II <br />MIN./MAX. TEMP <br />-26°C / 32°C <br />sc. H Se' ' cni <br />!System and Performance <br />—" <br />Mk! 111 <br />1111 <br />Max. efficiency 99.0% <br />CEC efficiency 98.5% <br />Standby / night consumption 5 W <br />OTHER NOTES <br />NO POSITION, DISTANCE, OR CLEARANCE <br />ISSUES WITH OVERHEAD ELECTRIC SERVICE <br />LINES OR OTHER UTILITIES IN RELATION TO <br />THE PV PANELS <br />24/7 UNESCORTED KEYLESS ACCESS FOR <br />THE UTILITY METERS AND UTILITY AC <br />DISCONNECT <br />Environment <br />CPS SCH275KTL-DO/US-800 <br />The 250/275 kW high power CPS three-phase string inverters are designed for ground -mount applications. The units are <br />high advanced, and reliable inverters designed specifically for the North American environment and rid. <br />Enclosure protection degree NEMA 4X <br />Cooling method Variable speed cooling fans 1 <br />Operating temperature range -22°F to 140°F / -30°C to 60°C (derate from 107°F / 42°C) <br />Non -operating temperature range -40°F to 140°F (-40°C to 60°C) <br />Operating humidity 0-100% <br />Operating altitude 8202 ft / 2500 m (no derating) <br />performance, <br />g p g p y g <br />High broad NEMA Type inverter <br />Audible noise < 80 dBA @ 1 m and 77°F (25°C) <br />efficiencies, wide operating voltages, temperature ranges, and 4X enclosure enable this <br />IDisplay and Communication <br />platform to operate at high performance across many applications. The SCH275KTL inverters include a selectable active <br />User interface and display LED indicators, Wi-Fi and app <br />power of either 250 kW or 275 kW (factory default) with 12 MPPTs and are available with either 36 fused PV string inputs <br />Inverter monitoring Modbus RS485 / PLC4/ CAN <br />or 24 unfused PV string inputs. The CPS FIexOM solution enables communication, controls and remote product upgrades. <br />Site -level monitoring CPS FIexOM (1 per 32 inverters) <br />Key Features <br />• Anti-PID function 12 MPPTs with 36 fused inputs or 24 unfused inputs <br />• Reactive Power at Night function Copper and Aluminum compatible AC connections <br />• CPS FIexOM Gateway enables remote firmware upgrades NEMA Type 4X outdoor rated, tough tested enclosure <br />Integrated DC disconnect switch Full power capacity up to 42°C <br />• Protection functions for enhanced reliability and safety Standard 5-year warranty with extensions to 20 years <br />Modbus data mapping SunSpec / CPS <br />Remote diagnostics / firmware upgrade functions Standard / (with FIexOM Gateway) <br />Mechanical <br />Dimensions (H x W x D) 27.2 x 41.3 x 15.7 (690 x 1050 x 400 mm) <br />Weight Inverter: 262 Ibs (119 kg) <br />Mounting / installation angle Vertical installation <br />AC termination Stud type terminal (wire range: 4/0 AWG - 750 kcmil AL/CU, lugs not supplied) <br />DC termination 36 fused input: screw clamp fuse holder (wire range #14-#8 AWG CU) <br />24 non -fused input: screw clamp terminal (wire range #14-#8 and #6-#4 AWG CU)5 <br />Fused string inputs (3 per MPPT)6 25 A fuses provided (values up to 30 A acceptable)- 30A FUSES INCLUDED <br />1 <br />REVISIONS <br /># <br />DESCRIPTION <br />BY <br />CHK'D <br />DATE <br />0 <br />IC SET <br />TB <br />MH <br />12/23/2024 <br />1 <br />2 <br />• Selectable max AC active power of 250 kW or 275 kW Supported comm protocols (Modbus RTU, TCP/IP, PLC, CAN) <br />Safety <br />UL 1741-SA to CA Rule 21, including SA14-SA18 UL 1741-SB IEEE 1547-2018 <br />Certifications and standards UL1741-SA/SB Ed.3, CSA-C22.2 NO.107.1-16, IEEE1547a-2014, IEEE 1547-2018; FCC PART 15 <br />DRAWN BY : <br />• certified and certified <br />Selectable grid standard IEEE 1547a-2014, IEEE 1547-2018, CA Rule 21, ISO -NE <br />TONY BRIENZA <br />Smart -grid features Volt-RideThru, Freq-RideThru, Ramp -Rate, Specified-PF, Volt -VAR, Freq-Watt, Vol -Watt <br />Protection Functions11. <br />PROJECT NAME & JOB #: <br />Reactive Power at Night Yes <br />CON N EXUS LANDFILL <br />Anti-PID function Yes <br />SHEET DESCRIPTION : <br />Insulation resistance monitoring Yes <br />Onboard fault oscillography Yes <br />INVERTER DATA SHEET <br />PV MPPT current monitoring Yes <br />SHEET SIZE: <br />Residual current monitoring Yes <br />Output short-circuit protection Yes <br />36X24 <br />Output overvoltage protection Yes <br />SPACE FOR PE STAMP : <br />Go <br />Fci-pahir,.„v„etc,nc,tre„ <br />(warranty <br />Standard 5 years <br />I hereby certify that this plan, specification, <br />or report was prepared by me or under my <br />direct supervision and that I am a duly <br />Licensed Professional Engineer under the laws <br />of the state of Minnesota. <br />Ai . <br />Signature ,I <br />C: us <br />Extended terms 10, 15, and 20 years <br />© CHINT POWER SYSTEMS AMERICA 2024/8-MKT NA Chint Power Systems America <br />1380 Presidential Drive, Suite 100, Richardson, TX 75081 <br />Tel: 855-584-7168 Mail: AmericaSales@chintpower.com Web: www.chintpowersystems.com <br />1) See user manual for information regarding MPPT voltage range when operating at non -unity PF. 4) CPS AC -PLC Kit required for AC PLC communication. <br />2) Inverter is factory set to 275 kW by default. Contact CPS to enable the 250 kW setting. 5) One threaded hole per MPPT for connecting #6-#4 AWG CU. <br />3) The output voltage range and output frequency range may differ according to the specific grid standard. 6) Fused string inputs only applicable to the SCH275KTL 36-input model. <br />m <br />DNaate:e: 01/24/2025MichaelHerman License Number: 57145 <br />SHEET : <br />PV-5.1 <br />