My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Public Works Committee - 03/27/2025
Ramsey
>
Public
>
Agendas
>
Public Works Committee
>
2025
>
Agenda - Public Works Committee - 03/27/2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 2:42:53 PM
Creation date
3/27/2025 2:27:16 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Public Works Committee
Document Date
03/27/2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OMB <br />■Ilow <br />CEDHR CREEI( <br />e-rt-e-rgY <br />3.53 <br />[90] <br />TYP. <br />3,53 <br />[90] <br />TYP. <br />a <br />} <br />PARKING <br />STAND <br />(ONE PER <br />BUSHING) <br />6.13 <br />[156] <br />71.00 <br />[1803] <br />51.00 <br />[1295] <br />A — <br />10.50 15.00 - w-L-0 15.00 <br />[267] <br />[381] [381] <br />•N 3.51 <br />[89] <br />TYP. <br />GROUNDING LUG <br />FOR #2 TO 4/0 <br />COPPER CONDUCTOR <br />38.75 <br />[984] <br />FRAME MOUNTING <br />FRO <br />T V <br />EW <br />A <br />RECLOSER ELECTRICAL INFORMATION <br />SEE NOTES FOR LIMITATIONS <br />RATED VOLTAGE (MAXIMUM) <br />IMPULSE LEVEL ( BIL ) <br />CONTINUOUS CURRENT, RMS SYM <br />CURRENT INTERRUPTING, RMS SYM <br />AC I MIN. WITHSTAND ( DRY ) <br />DC 15 MIN, WITHSTAND <br />MOMENTARY CURRENT, RMS ASYM <br />MAKING CURRENT, RMS ASYM <br />SHORT -TIME WITHSTAND RATING <br />(3 SEC, DURATION), RMS SYM <br />15.5 <br />110 <br />800 <br />12.5 <br />35 <br />53 <br />20.0 <br />20.0 <br />12.5 <br />KV <br />KV <br />AMP <br />KA <br />KV <br />KV <br />KA <br />KA <br />KA <br />AI <br />co <br />A2 52 C2 <br />Y <br />THREELINE DIAGRAM <br />IN SERVICE WEIGHT APPROX. 1200 LBS / 545 KG <br />SHIPPING WEIGHT APPROX . 1450 LBS / 659 KG <br />20.00 <br />[508] <br />f PHASE CI <br />GROUND BOSS <br />WITH 1/2"-13 <br />THREAD <br />PHASE C2 <br />THREE LINE <br />DIAGRAM <br />NAMEPLATE <br />NAMEPLATE <br />(ONE PER <br />INTERRUPTER) <br />MANUAL <br />TRIP LEVER <br />(TYP.) <br />(SEE NOTE 4) <br />.625" DIA. <br />HARDWARE <br />(4)-SUPPLIED <br />BY USER <br />.25" STAINLESS STEEL <br />ANCHOR BRACKET <br />WITH .875" X I. 125" <br />SLOTTED HOLE <br />SUPPLIED BY G&W <br />CONCRETE <br />PAD <br />NNCLOSURE <br />VOUNTING <br />DETAIL "A" <br />ENCLOSURE <br />2.19 <br />56MM - <br />TYP. <br />82.15 <br />[2087] <br />HEIGHT <br />WITH <br />FLIP TOP <br />OPENED <br />r <br />7.50 <br />[191] <br />30 00 <br />[762] <br />r <br />30.26 <br />0 o <br />1 <br />[1219] <br />FLIP TOP LID <br />[769] <br />CABLE <br />COMPARTMENT <br />Z <br />Y <br />ALUMINUM <br />HEAD CASTING <br />VIPER CONTROL <br />GROUNDING BUSS <br />Oof <br />0 <br />L <br />0 <br />11 <br />(4) LIFTING <br />PROVISIONS WITH <br />1.25 DIA. HOLE <br />INTERRUPTER <br />MODULE <br />INTERNAL <br />VOLTAGE SCREEN <br />- INTERNAL CURRENT <br />TRANSFORMER & <br />VOLTAGE SCREEN <br />(Y SIDE) <br />GALVANIZED OPEN <br />BOLTED MOUNTING <br />FRAME <br />54.00 <br />[1372] <br />ECLOSE <br />21.42 21.50 <br />[544] <br />S <br />D <br />EC <br />[546] <br />FRAME MOUNTING <br />SECT ON A - A <br />FICS: <br />.563 X 1.000 <br />SLOTTED HOLE <br />(4 MTG. HOLES) <br />RECLOSER IS EQUIPPED WITH A CONTROL: SEL651R22CXGAXAEIII2XXXX <br />CONTROLLER WEIGHT: 150 LBS APPROXIMATE. <br />CONTROL CABLE IS CONNECTORIZED ON BOTH ENDS. CABLE LENGTH 10 FT. <br />CABLES FROM MODULES ARE HARDWIRED INTO JUNCTION BOX. <br />CT RATIO FACTORY SET AT 1000:1 RATIO <br />VIPER IS EQUIPPED WITH SIX VOLTAGE SENSORS, THREE INTERNAL LOW <br />ENERGY ANALOG (LEA) VOLTAGE SENSORS ARE LOCATED ON THE Y SIDE <br />AND THREE INTERNAL LEA VOLTAGE SENSORS ARE LOCATED ON THE Z SIDE. <br />MAXIMUM OUTPUT OF INTERNAL LEA VOLTAGE SENSOR IS 5 VAC WITH A 10,000:1 RATIO. <br />LEA VOLTAGE SENSING IS CALIBRATED AT THE FACTORY USING RATIO <br />CORRECTION FACTORS (RCFS) PROVIDED WITH THE VIPER. <br />RCFS ARE PROGRAMMED INTO THECONTYROL PAIRED WITH THE VIPER. RCFS MUST BE <br />REPROGRAMMED IF DIFFERENT CONTROL IS USED, SEE LABEL INCLUDED WITH THE <br />CONTROL FOR RCF VALUES AND EQUIVALENT PT RATIO. <br />PHASE C <br />LOW VOLTAGE <br />CONTROL <br />ENCLOSURE <br />RATIO CORRECTION <br />FACTORS STICKER <br />ON FRONT OF <br />JUNCTION BOX <br />MODULE <br />CABLE <br />ACCESS <br />o o <br />U o <br />C7 0� <br />a <br />0 o� <br />El <br />. @ <br />0 <br />0 p . <br />0 <br />0 <br />0 <br />0 0101 <br />0 .® 0O <br />p <br />o0 <br />© a- 0 n <br />0 <br />LI <br />L, <br />li <br />POLYCARBONATE OPERATING <br />MECHANISM COVER <br />(LIGHT GRAY) <br />JUNCTION BOX---// <br />RECLOSER CONTROL <br />CABLE AND HARDWARE <br />3AC <br />� U <br />INTERNAL <br />HAZARD <br />WARNING <br />LABEL <br />EW <br />- PHASE B <br />- PHASE A <br />CONTACT <br />POSITION <br />INDICATOR <br />(RED -CLOSED) <br />(GREEN -OPEN) <br />ENTRANCES <br />BUSHING ELECTRICAL CHARACTERISTICS <br />IEEE 386 INTERFACE <br />Y <br />15.5KV 800A DEADBREAK APPARATUS BUSHING <br />INTERFACE II <br />Z <br />15,5KV 800A DEADBREAK APPARATUS BUSHING <br />INTERFACE II <br />DATE <br />CUSTOMER <br />ORDER NO. <br />n FOR RECORD <br />PRINT IDENTIFICATION <br />G&W NO, <br />FOR APPROVAL -NO MORE WORK TO BE <br />DONE UNTIL APPROVAL <br />IS RECEIVED <br />ITEM NO. <br />CT RATIO 1000:1 <br />CONTROLLER NO. SEL651R22CXGAXAEIII2XXXX <br />DC/DC OPTION USES OUTPUT <br />ALL PRIMARY DIMENSIONS ARE IN INCHES. <br />ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS. <br />CEDAR CREEK ENERGY <br />3155 104TH LN NE <br />BLAINE, MN, 55449 <br />PHONE # 763-450-9763 <br />PROJECT ADDRESS <br />6501 SUNWOOD DR. NW <br />RAMSEY, MN 55303 <br />UTILITY CUSTOMER OF RECORD <br />CELF 2024 LLC <br />PROJECT DESCRIPTION <br />SYSTEM SIZE (DC) <br />5.046 MW <br />SYSTEM SIZE (AC) <br />4.125 MW <br />DC/AC RATIO <br />1.223 <br />AZIMUTH <br />90/270° <br />TILT <br />+/- 52° <br />MODULE TYPE <br />JINKO <br />JKM580N-72HL4-BDV <br />MODULE COUNT <br />8,700 <br />INVERTER TYPE <br />CPS SCH275KTL-DO/US 800 <br />275 kW <br />INVERTER POWER (kW) <br />275kW <br />RACKING <br />SINGLE AXIS TRACKER <br />MONITORING <br />ALSO ENERGY <br />PROJECT AREA <br />-23.04 ACRE <br />MIN./MAX. TEMP <br />-26°C / 32°C <br />OTHER NOTES <br />NO POSITION, DISTANCE, OR CLEARANCE <br />ISSUES WITH OVERHEAD ELECTRIC SERVICE <br />LINES OR OTHER UTILITIES IN RELATION TO <br />THE PV PANELS <br />24/7 UNESCORTED KEYLESS ACCESS FOR <br />THE UTILITY METERS AND UTILITY AC <br />DISCONNECT <br />REVISIONS <br /># <br />DESCRIPTION <br />BY <br />CHK'D <br />DATE <br />0 <br />IC SET <br />TB <br />MH <br />12/23/2024 <br />1 <br />2 <br />DRAWN BY : <br />TONY BRIENZA <br />PROJECT NAME & JOB #: <br />CON N EXUS LANDFILL <br />SHEET DESCRIPTION : <br />VIPER RECLOSER SPECIFICATIONS <br />SHEET SIZE: <br />36X24 <br />SPACE FOR PE STAMP : <br />I hereby certify that this plan, specification, <br />or report was prepared by me or under my <br />direct supervision and that I am a duly <br />Licensed Professional Engineer under the laws <br />of the state of Minnesota. <br />Signature. <br />Name: Michael Herman <br />Date: O1/24/2025 License Number: 57145 <br />SHEET : <br />PV-5.9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.