Laserfiche WebLink
COMMERCIAL PLAN R E VI E W <br />FOR CODE COMPLIANCE <br />BUNKER LAKE INDUSTRIAL PARK\BUILDING #5\LEASEHOLDS\IN THE GAME PICKLEBALL AND GOLF\IN THE GAME PICKLEBALL AND GOLF-LH1 <br />E <br />0 <br />c <br />a) <br />L <br />GENERAL INFORMATION <br />A. PROJECT NAME: <br />B. PROJECT LOCATION: <br />In The Game Pickle Ball And Golf <br />Bunker Lake Industrial Park Building #5 <br />Ramsey, Minnesota <br />APPLICABLE CODES: <br />A. RAMSEY ZONING ORDINANCE <br />B. MINNESOTA STATE BUILDING CODE (MSBC) <br />— INCLUDING — <br />C. CHAPTER 1305 — INT'L BUILDING CODE 2020 Edition <br />D. CHAPTER 1311 — INT'L EXISTING BUILDING CODE 2020 Edition <br />E. CHAPTER 1315 — NATIONAL ELECTRIC CODE 2023 Edition <br />F. CHAPTER 1322/23 — INT'L ENERGY CONSERVATION CODE 2024 Edition <br />G. CHAPTER 1341 — MN ACCESSIBILITY CODE 2020 Edition <br />H. CHAPTER 1346 — INT'L MECHANICAL CODE 2020 Edition <br />I. CHAPTER 4714 — MN PLUMBING CODE 2020 Edition <br />Current Edition <br />BUILDING CLASSIFICATION <br />A. OCCUPANCY GROUPS/ TYPE OF CONST (IBC Chpt 3 & IBC Chpt 6) <br />1, Indoor — Group A-3 <br />Recreation — Type of Construction — II—B <br />— Area — 15,580 s.f. <br />2. Mixed Occupancy (IBC 508) <br />— Group A-3 Is A Non —Separated Use From Adjacent Occupancies <br />3. Incidental Uses (IBC 509) <br />— None <br />B. FIRE —RESISTANCE —RATED CONSTRUCTION <br />1, Fire Walls (IBC 706) <br />— Not Required — <br />2. Fire Barriers (IBC 707) <br />— Not Required — <br />3, Fire Partitions (IBC 708) <br />— Not Required — <br />C. INTERIOR FINISH REQUIREMENTS <br />1, Minimum Wall And Ceiling Finish <br />Building Component <br />Requirement (IBC <br />Finish Class <br />Table 803.13) <br />Vertical Exits/ <br />Exit Passageways <br />Class B <br />Exit Access Corridors/ <br />Other Exit ways <br />Class B <br />Rooms and Enclosed <br />Spaces <br />Class C <br />AUTOMATIC SPRINKLER REQUIREMENTS <br />A. AN EXISTING NFPA 13 AUTOMATIC SPRINKLER SYSTEM IS PROVIDED <br />THROUGHOUT THE BUILDING (IBC 903.3.1.1) <br />MEANS OF EGRESS <br />A. <br />B. <br />DESIGN OCCUPANT LOAD (IBC Chpt 1004) <br />1, Total Occupants = 63 Occupants (See Plan) <br />EXIT/ EXIT ACCESS <br />1. Number Required (IBC Table 1006.2,1, 1006.3.2) <br />2. Number of Accessible (1009) <br />3. Arrangement (IBC 1007) <br />— Not Less Than 1/3 Overall <br />4, Travel Distance Maximums <br />— Exit Access (IBC 1017) <br />— Common Path of Egress (IBC 1006.2.1) <br />— Dead Ends (IBC 1020.4) <br />5. Sizing (The Greater of Two Conflicting Widths <br />Design Egress Sizing (IBC 1005.3) <br />Stairways (Occ Load x .3) <br />Other Components (Occ Load <br />Stairways (IBC 1011.2) <br />Corridors (IBC 1020.2) <br />Exit Passageways (IBC 1024.2) <br />Exit Doors (IBC 1010,1,1) <br />x .2) <br />= 2 <br />Required IBC = 2 <br />Diagonal (Sprinklered Building) <br />= 250' <br />= 75' <br />= 20' <br />Shall Be Used) <br />= N/A <br />= 12.6" <br />= 44" <br />= 44" <br />= 44" <br />= 32" Min Clear <br />48" Max Nom <br />6. Doors <br />— Swing (IBC 1010.1.2.1) <br />Side Hinged Swinging Out At Occupant Load Of 50 Or More <br />— Landings (IBC 1010.1.6) <br />Width Not Less Than Width of Door Or Stairway <br />Length in Direction of Travel Not Less Than 44" <br />— Thresholds (IBC 1010,1.7) <br />Max Height = 1/2" — 1:2 Beveled Edge If 1/4"-1/2" <br />— Door Arrangement (IBC 1010.1,8) 48" + Door Width Apart <br />— Lock or Latch (IBC 1010,1.9) <br />Operable From Egress Side Without Use of Knowledge or Keys. <br />Manually Operated Flush Bolts Permitted on Inactive leaf. <br />— Panic/ Fire Exit Hardware (IBC 1010.1.10) <br />Required At Exit/Exit Access Doors <br />PLUMBING FIXTURES <br />A. NUMBER FIXTURES REQUIRED (IBC 2902,1) <br />1, Based On 63 Occupants — Assembly Occupancy <br />— 31 Male Occupants <br />— 32 Female Occupants <br />Fixture <br />Required <br />Provided <br />Men <br />Women <br />Men <br />Women <br />Unisex <br />Water Closets <br />0.25 <br />0.49 <br />2 <br />2 <br />— <br />Urinals <br />— <br />— <br />— <br />— <br />— <br />Lavatories <br />0.16 <br />0.16 <br />2 <br />2 <br />— <br />Bathtubs/ Showers <br />— <br />— <br />— <br />— <br />— <br />Drinking Fountains <br />0.13 <br />2 <br />Service Sink <br />1 <br />1 <br />B. LOCATION OF FIXTURES (IBC 2902.3.3) <br />— Not More Than 1 Story Above Or Below Regular Working Area <br />— Travel Distance Less Than 500 ft <br />C. SIGNAGE (IBC 2902,4) <br />— A Legible Sign For Each Sex Shall Be Provided Near The <br />Entrance To The Toilet Facility <br />OTHER <br />A. ACCESSIBILITY <br />1. Building is Accessible <br />B. GUARDS (IBC 1015) <br />1. 42" High Minimum Guards Shall Be Installed Where A Change In <br />Levels Drops 30" Or More. <br />C. SAFETY GLAZING (IBC 2406) <br />1, Safety Glazing Shall Be Installed In Hazardous Locations As <br />Specified In IBC 2406.4 <br />D. FIRE ALARM AND DETECTION SYSTEMS <br />1, Fire Alarm And Detection System Not Required (IBC 907.2) <br />2. If Required Provide Audible And Visible Alarm Notification Devices <br />(IBC 907.5, NFPA 72) <br />❑1 8" STEEL STUDS <br />BUILD TO DECK <br />5/8" GYP BOARD <br />8" STEEL STUDS <br />BATT INSULATION <br />FOR SOUND <br />5/8" GYP BOARD <br />❑2 3-5/8" STEEL STUDS <br />BUILD TO 8'-0" A.F.F. <br />5/8" GYP BOARD <br />3-5/8" STEEL STUDS <br />BATT INSULATION <br />FOR SOUND <br />5/8" GYP BOARD <br />❑3 3-5/8" STEEL STUDS <br />BUILD TO 12'-0" A.F.F. <br />5/8" GYP BOARD <br />3-5/8" STEEL STUDS <br />BATT INSULATION <br />FOR SOUND <br />5/8" GYP BOARD <br />® 3-5/8" STEEL STUDS <br />BUILD TO 4'-0" A.F,F. <br />WALL TYPES <br />SCALE: 1" = 1'-0" <br />4' 0" <br />PAINTED <br />HOLLOW METAL <br />CLEAR GLASS <br />(WINDOW TYPES <br />N <br />H1 SCALE: 1/4" = 1'-0H 1 SCALE: 1 /4" = 1'-0" <br />2' SEE SCHD..2" <br />O <br />N <br />5/8" GYP BOARD <br />3 5/8" STEEL STUDS <br />5/8" GYP BOARD <br />T = TEMPERED GLASS <br />2".SEE SCHD..2" <br />0 <br />F1 PAINTED <br />HOLLOW METAL <br />2 ANODIZED <br />ALUMINUM <br />aDOOR FRAME <br />SCALE: 1/4•• = 1•_0••4 DOOR FRAME TYPES <br />SCALE: 1/4" = 1'-0" <br />ff///ik,( <br />D 1STTAINEDOLID O&E SEAOD ALLD ® STTAINNEDO&E SEAOD ALLD ®ALUODIZED <br />MINUM <br />DOOR TYPES <br />SCALE: 1/4" = 1'-0" <br />T = TEMPERED GLASS <br />DOOR & FRAME SCHEDULE <br />DR # <br />DOOR SIZE <br />THICK <br />DOOR <br />FRAME <br />REMARKS <br />100A <br />(2)3'-0"x7'-0" <br />1-3/4" <br />D3 <br />F2 <br />PUSH/PULL ONLY <br />100B <br />3'-0"x7'-0" <br />1-3/4" <br />D3 <br />F2 <br />PANIC HARDWARE <br />100C <br />3'-0"x7'-0" <br />1-3/4" <br />D3 <br />F2 <br />— <br />101 <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />— <br />102 <br />3'-0"x4'-0" <br />1-3/4" <br />D1 <br />—- <br />106 <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />— <br />107 <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />— <br />108 <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />— <br />109 <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />— <br />110 <br />3'-0"x7'-0" <br />1-3/4" <br />D2 <br />F1 <br />— <br />111 <br />3'-0"x7'-0" <br />1-3/4" <br />D2 <br />F1 <br />— <br />112A <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />— <br />112B <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />— <br />113 <br />3'-0"x7'-0" <br />1-3/4" <br />D1 <br />F1 <br />— <br />NOTES: <br />1. ALL DOOR HARDWARE TO BE SPECIFIED & PROVIDED BY CONTRACTOR <br />2. ALL EXIT HARDWARE SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, <br />OR TWISTING OF THE WRIST. MOUNT HARDWARE BETWEEN 34"-48" <br />(ANSI A117.1-404.2.6) <br />NOTE TO ALL DESIGN/BUILD CONTRACTORS <br />AND THEIR SUB —CONTRACTORS: <br />THE DESIGN/BUILD CONTRACTOR IS RESPONSIBLE FOR <br />REVIEWING ALL MECHANICAL, ELECTRICAL, PLUMBING, <br />FIRE SPRINKLER, OR ANY OTHER DESIGN/BUILD SUB— <br />CONTRACTOR'S DOCUMENTS AS PERTAINING TO THE <br />WORK FOR THIS PROJECT. IT IS THE DESIGN/BUILD SUB— <br />CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE DESIGN/BUILD <br />CONTRACTOR OF ANY CONFLICTS WITH THE ARCHITECTURAL <br />AND STRUCTURAL DOCUMENTS DUE TO SIZES, LOCATIONS, <br />QUANTITIES, ROUGH —IN DIMENSIONS AND CODE INTERPRE— <br />TATIONS. THE DESIGN/BUILD CONTRACTOR IS RESPONSIBLE <br />FOR NOTIFYING THE ARCHITECT IMMEDIATELY OF ANY <br />ARCHITECTURAL REVISIONS REQUIRED DUE TO THE COOR— <br />DINATION OF EACH DESIGN/BUILD SUB —CONTRACTOR'S <br />DOCUMENTS. <br />ROOM FINISH SCHEDULE <br />RM# <br />DESCRIPTION <br />FLOOR <br />BASE <br />N.WALL <br />E.WALL <br />S.WALL <br />W.WALL <br />CLG. <br />HGHT <br />REMARKS <br />100A <br />VESTIBULE <br />CONC <br />VINYL <br />PRECAST <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />12'-0" <br />VINYL BASE ON PT/GYP ONLY <br />100B <br />VESTIBULE <br />CONC <br />VINYL <br />PRECAST <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />ACT <br />10'-0" <br />VINYL BASE ON PT/GYP ONLY <br />101 <br />OFFICE <br />CARPET <br />VINYL <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />12'-0" <br />— <br />102 <br />PLAY FLOOR <br />CONC <br />VINYL <br />PRECAST <br />PT/GYP <br />PT/GYP <br />PRECAST <br />OPEN <br />VARIES <br />SEE PLAN FOR COURT LOC. <br />103 <br />GOLF SIM <br />TURF <br />VINYL <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />OPEN <br />VARIES <br />— <br />104 <br />GOLF SIM <br />TURF <br />VINYL <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />OPEN <br />VARIES <br />— <br />105 <br />GOLF SIM <br />TURF <br />VINYL <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />OPEN <br />VARIES <br />— <br />106 <br />MEN <br />C.T. <br />C.T. <br />CT/WST — SEE PLAN FOR LOC. <br />PT/GYP <br />8'-0" <br />— <br />107 <br />MEN <br />C.T. <br />C.T. <br />CT/WST — SEE PLAN FOR LOC. <br />PT/GYP <br />8'-0" <br />— <br />108 <br />WOMEN <br />C.T. <br />C.T. <br />CT/WST — SEE PLAN FOR LOC. <br />PT/GYP <br />8'-0" <br />— <br />109 <br />WOMEN <br />C.T. <br />C.T. <br />CT/WST — SEE PLAN FOR LOC. <br />PT/GYP <br />8'-0" <br />— <br />110 <br />LOUNGE <br />LVT <br />VINYL <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />ACT <br />10'-0" <br />— <br />111 <br />OFFICE <br />CARPET <br />VINYL <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />ACT <br />10'-0" <br />— <br />112 <br />OFFICE <br />CARPET <br />VINYL <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />PT/GYP <br />ACT <br />10'-0" <br />— <br />113 <br />UTILITY <br />CONC <br />VINYL <br />PT/GYP <br />PT/GYP <br />PRECAST <br />PT/GYP <br />OPEN <br />VARIES <br />VINYL BASE ON PT/GYP ONLY <br />ABBREVIATIONS: <br />CONC = SEALED CONCRETE <br />C.T. = CERAMIC TILE <br />CT/WST = CERAMIC TILE WAINSCOT TO 5'-0" A.F.F. <br />PT/GYP = PAINTED GYPSUM BOARD <br />ACT = ACOUSTICAL CEILING TILE <br />LVT = LUXURY VINYL TILE <br />0400'-0"0 0 0 <br />50'-0" <br />50'-0" <br />50'-0" 50'-0" 50'-0" <br />50'-0" 50'-0" 50'-0" <br />IN THE G <br />PICKLEBA <br />ME <br />L AND GO <br />1=f <br />KEY PLAN <br />SCALE: 1" = 60'-0" <br />NORTH <br />AOrNk <br />0 <br />0 <br />50'-0" <br />50'-0" <br />ACRYLIC CUSHION COURT WITH DOUGLA <br />PREMIER. POSTS, NET, AND STRAPS <br />(5 THUS — BY TENANT) GRIND FLOOR <br />REQUIRED TO PREP FOR FLOOR FINISH <br />AS <br />PROVIDE PANIC <br />HARDWARE <br />VEST. <br />1▪ 5'-3' <br />10' — <br />11 <br />13'-5" <br />OFFICE <br />101 <br />1 OCC <br />3 <br />101 <br />4 <br />Qisp <br />PROVIDE PANIC <br />HARDWARE <br />100A <br />in <br />-,8 1/2" 8'—O" <br />/ <br />COURT 3 <br />4 OCC <br />x x <br />0 <br />F.E. <br />4 FT HIGH <br />VINYL COATED <br />CHAINLINK FENCE <br />PROVIDE PANIC <br />HARDWARE <br />VEST. <br />100B <br />44'-0" <br />0I <br />NN <br />COURT <br />4 OCC <br />2 <br />PLAY FLOOR <br />COURT 4 <br />4 OCC <br />xx <br />102 <br />I D.F. E <br />E <br />GOLF SIM <br />103 <br />4 OCC <br />COUR4 OCC <br />5'- <br />GOLF SIM <br />104 <br />4 OCC20'-0" <br />EGOLSIM ' <br />4 OCC <br />0107 <br />C- <br />o <br />105 <br />MEN <br />106 <br />100B� <br />4' 5"_ri H <br />7'-11" <br />10, <br />,' 20'-0" <br />4 <br />0 <br />1 <br />1- <br />30'-6" <br />—JI <br />MEN <br />107 <br />WOMEN <br />< 1 <br />108 <br />WOMEN <br />109 <br />REF <br />U 0 \ <br />-I— U I <br />'-0" 20'-0" 5'-",L,a 0 `° \ <br />/ J / Z O Li-N O <br />4'— 7 1 /2' l O 7 N IIIOx JW1 ''''1 r <br />0\ m <br />1 <br />11 <br />28'-9 <br />COURT 5 x <br />4 OCC <br />F.E. <br />UTILITY <br />113 <br />2 OCC <br />3 <br />co <br />'-1f" <br />TRACKMAN 4 <br />GOLF SIMULATOR <br />(3 THUS — BY TENANT) <br />VERIFY WALL AND POWERREQUIREMENTS WITH <br />SIMULATOR SUPPLIER <br />ALTERNATE: <br />10'-6" BASE AND UPPER <br />CABINETS WITH DROP —IN <br />STAINLESS STEEL SINK <br />TOP OF COUNTER AT <br />34" MAX A.F.F. <br />FUTURE <br />EXPANSION <br />15,580 U.S.F. X 1,0029435 = 15,626 R.S,F. PLAN <br />NORTH <br />FLOOR PLAN <br />SCALE: 1/16" = 1'-0" <br />PLAN NOTES <br />1, e = EXIT SIGNAGE. PROVIDE EMERGENCY <br />BACK—UP POWER <br />2. = EMERGENCY LIGHTING. PROVIDE <br />EMERGENCY BACK—UP POWER AND <br />(1) FOOT CANDLE AT THE WALKING SURFACE. <br />3. FE. = FIRE EXTINGUISHER. VERIFY SIZE <br />AND SPACING WITH BUILDING OFFICIAL. <br />LAMPERT <br />ARCHITECTS <br />420 Summit AvenueSt. Paul, MN 55102 iUI <br />Phone:763.755.1211 Fax:763.757.2849 <br />lampert@lampert—arch.com <br />ARCHITECT CERTIFICATION: <br />I HEREBY CERTIFY THAT THIS PLAN, <br />SPECIFICATION OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT <br />SUPERVISION AND THAT I AM A DULY <br />LICENSED ARCHITECT UNDER THE <br />LAWS OF THE STATE OF MINNESOTA. <br />SIGNATURE <br />LEONARD LAMPERT <br />PRINT NAME <br />13669 <br />LICENSE NO. <br />4/10/25 <br />DATE <br />W <br />Ramsey, Minnesota <br />Copyright 2025 <br />Leonard Lampert Architects Inc. <br />Project Designer: JAMES B <br />Drown By: JRB <br />Checked By: LL <br />Revisions <br />3/31 /25 <br />PRELIMINARY <br />4/10/25 <br />ISSUE FOR PERMIT <br />CODE REVIEW <br />FLOOR PLAN <br />KEY PLAN <br />Sheet Number <br />4. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS <br />PRIOR TO CONSTRUCTION <br />Project No. 250304-4 <br />