STORM WATER POLLUTION
<br />PREVENTION PLAN (SWPPP)
<br />ALPINE DRIVE RECONSTRUCTION
<br />S.A.P. 199-106-012 & 199-107-010
<br />CITY OF RAMSEY
<br />ANOKA COUNTY, MINNESOTA
<br />RAMSEY,
<br />ANOKA COUNTY,
<br />,_MINNESOTA
<br />DESCRIPTION OF CONSTRUCTION ACTIVITIES AND STORMWATER MANAGEMENT:
<br />Construction activities include; Site Grading, Storm Sewer Construction, Temporary Erosion and Sediment
<br />Control, Roadway Construction, and Permanent Stabilization.
<br />Project Description: This project consists of reconstruction of 1.02 miles of existing bituminous streets
<br />including spot replacement of concrete curb and gutter. The drainage for the existing streets uses storm
<br />sewer inlets at low points. The proposed runoff will be collected in storm sewer inlets in the curb and gutter,
<br />and routed to the same low points. There is no change to the outfall location of the storm water runoff
<br />proposed with this project.
<br />RESPONSIBLE PARTIES:
<br />The Contractor and Owner must apply for coverage under the MPCA's General Storm Water Permit for
<br />Construction Activity as required by the National Pollution Discharge Elimination System (NPDES) Phase II
<br />program. Coverage under the permit will begin automatically 7 calendar days after the electronic submittal
<br />date or after the postmarked date of a complete application. (Longer time frames will apply to areas
<br />disturbing 50 acres or discharge within 1 mile of a special water).
<br />COMPANY
<br />CONTACT PERSON
<br />PHONE
<br />OWNER:
<br />CITY OF RAMSEY
<br />BRUCE WESTBY, PE
<br />763-433-9825
<br />SWPPP DESIGNER:
<br />CITY OF RAMSEY
<br />JOE FERIANCEK, PE
<br />763-433-9893
<br />CONTRACTOR:
<br />STIE MANAGER:
<br />PARTY RESPONSIBLE FOR
<br />LONG TERM O&M:
<br />CITY OF RAMSEY
<br />BRUCE WESTBY, PE
<br />763-433-9825
<br />Individuals listed above, including the SWPPP preparer, individual overseeing implementation of, revising
<br />and amending the SWPPP, Individuals performing or supervising the installation, maintenance and repair of
<br />BMP's must be trained. At least one individual present on the permitted project, or available within 72 hours
<br />shall be trained in the applicable job duties. Documentation showing training commensurate with the job
<br />duties and responsibilities is required to be included in the SWPPP prior to any work beginning on the site.
<br />Copies of the SWPPP preparer information is included in the Project Manual. The Contractor shall provide
<br />information for the individual(s) overseeing implementation, supervising installation, maintenance, and
<br />repair of BMP's to be included in the Project Manual prior to the start of construction. This information shall
<br />be kept up to date until the project NOT is filed.
<br />Documentation shall include:
<br />a. Names of trained personnel associated with this project.
<br />b. Dates of training, names of instructor(s) and entity providing training.
<br />c. Content of training course or workshop including the number of hours trained.
<br />d. As an alternative to a, b, and c listed above, a photocopy of the current Erosion and Stormwater
<br />Management card issued by the University of Minnesota can be attached to the SWPPP as suitable
<br />documentation of training.
<br />DOCUMENTATION RETENTION:
<br />The following documentation will be retained for a period of not less than 3-years from the date of submittal
<br />of the NOT.
<br />1. The final SWPPP.
<br />2. Copies of all stormwater related permits required for the project.
<br />3. Records of all inspection and maintenance conducted during construction.
<br />4. Copies of all permanent operation and maintenance agreements; including all right-of-way, contracts,
<br />covenants and other binding requirements regarding perpetual maintenance.
<br />5. All required calculations for design of temporary and permanent BMP's.
<br />IMPLEMENTATION SCHEDULE AND PHASING:
<br />1. Furnish & Install perimeter sediment control and inlet protection.
<br />2. Reclamation of existing bituminous pavement.
<br />3. Rough grade site.
<br />4. Furnish & install bituminous pavement.
<br />5. Add additional temporary BMP's as necessary during construction based on inspection reports.
<br />6. Submit Notice of Termination (NOT) to MPCA within 30 days of final stabilization.
<br />FINAL STABILIZATION:
<br />The permittee(s) must ensure final stabilization of the site. The permittee(s) must submit a NOT within 30
<br />days after final stabilization is complete, or another owner/operator (permittee) has assumed control over
<br />all areas of the site which have not undergone final stabilization. Final stabilization can be achieved in one of
<br />the following ways:
<br />1. All soil disturbing activities at the site have been completed and all soils must be stabilized by a uniform
<br />perennial vegetative cover with a density of 70 percent over the entire pervious surface area, or other
<br />equivalent means necessary to prevent soil failure under erosive conditions and;
<br />a. All drainage ditches, constructed to drain water from the site after construction is complete, must be
<br />stabilized to preclude erosion;
<br />b. All temporary synthetic, and structural erosion prevention and sediment control BMP's (such as silt
<br />fence) must be removed as part of the site final stabilization; and
<br />c. The permittee(s) must clean out all sediment from conveyances and from temporary sedimentation
<br />basins to be used as permanent water quality management basins. Sediment must be stabilized to
<br />prevent it from being washed back into the basin, conveyances or drainage ways discharging off -site
<br />or to surface waters. The cleanout of permanent basins must be sufficient to return the basin to design
<br />capacity.
<br />2. Final vegetation cover shall be in the Project Specifications.
<br />3. For residential construction only, final stabilization has been achieved when temporary erosion protection
<br />and down gradient perimeter control for individual lots has been completed and the residence has been
<br />transferred to the homeowner. Additionally, the permittee must distribute the MPCA "Homeowner fact
<br />sheet" to the homeowner to inform the homeowner of the need for, and benefits of, final stabilization.
<br />SPECIAL ENVIRONMENTAL CONSIDERATIONS:
<br />Was an environmental review required for this project or any part of a common plan of development or sale that includes
<br />all or any portion of this project?
<br />NO
<br />Does any portion of the site have the potential to affect threatened or endangered species?
<br />NO
<br />Does any portion of this site discharge to a Calcareous Fen and the letter of approval from the DNR is located in the
<br />Project Manual?
<br />NO
<br />Will any portion of this site potentially affect properties listed on the National Register of Historic Places or a Known or
<br />Discovered Archeological site?
<br />NO
<br />Have any Karst features been identified in the project vicinity?
<br />NO
<br />Is compliance with temporary or permanent stormwater management design requirements infeasible for this project?
<br />NO
<br />POLLUTION PREVENTION MANAGEMENT MEASURES:
<br />The permittee(s) shall implement the following pollution prevention management measures on the site:
<br />1. Solid waste: collected sediment, asphalt and concrete millings, floating debris, paper, plastic, fabric,
<br />construction and demolition debris and other wastes must be disposed of properly and must comply with
<br />MPCA disposal regulations.
<br />2. Hazardous materials: oil, gasoline, paint and any hazardous substances must be properly stored, including
<br />secondary containment, to prevent spills, leaks or other discharge. Restricted access to storage areas
<br />must be provided to prevent vandalism. Storage and disposal of hazardous waste must be in compliance
<br />with MPCA regulations.
<br />3. External washing of trucks and other construction vehicles must be limited to a defined area of the site.
<br />Runoff must be contained and waste properly disposed of. No engine degreasing is allowed on site.
<br />GENERAL STORMWATER DISCHARGE REQUIREMENTS:
<br />All requirements listed in Part 15 of the permit for the design of permanent stormwater treatment system
<br />and discharge have been included in the preparation of this SWPPP. These include but are not limited to:
<br />1. The expected amount, frequency, intensity and duration of precipitation.
<br />2. The nature of stormwater runoff and run-on at the site.
<br />3. Peak flow rates and stormwater volumes to minimize erosion at outlets and downstream channel and
<br />stream bank erosion.
<br />4. The range of soil particle sizes expected to be present on the site.
<br />RECEIVING WATERS:
<br />Recieving waters, including surface water, wetlands, Public Waters, and stormwater ponds are identified on
<br />the USGS 7.5min quad map within 1 mile of the project boundary. Receiving waters that are impaired, the
<br />impairment and WLA are listed as follows. All specific BMP's relative to construction activities listed in this
<br />permit for special and impaired waters have been incorporated into this plan. All specific BMP's listed in
<br />approved TMDLs and those BMP's listed for construction related waste load allocations have also been
<br />incorporated.
<br />NAME OF WATER
<br />BODY
<br />TYPE (DITCH, POND,
<br />WETLAND, LAKE,
<br />ETC.)
<br />APPENDIX A SPECIAL
<br />WATER?
<br />FLOWS TO
<br />WATER
<br />WITHIN 1 MILE?
<br />USEPA APPROVED
<br />TMDL?
<br />TMDL?
<br />RUM RIVER
<br />RIVER
<br />YES
<br />YES
<br />YES
<br />IMPAIRMENTS: DO; FISHESBIO; INERTBIO
<br />PROJECT AREAS:
<br />Total project size (disturbed area) =
<br />Existing area of impervious surface =
<br />Post construction area of impervious surface =
<br />New impervious surface area created =
<br />Planned construction start date:
<br />Planned construction completion date:
<br />PROJECT LOCATION:
<br />6.59
<br />5.56
<br />5.56
<br />0.00
<br />acres
<br />acres
<br />acres
<br />acres
<br />June 2025
<br />October 2025
<br />County: ANOKA Township: 32 Range: 25 Section: 16 Latitude: 45.248537 Longitude: -93.416690
<br />PERMANENT STORMWATER MANAGEMENT SYSTEM:
<br />Type of storm water management used if more than 1 acre of new impervious surface is created:
<br />a. Wet Sedimentation Pond
<br />b. Infiltration / Filtration
<br />c. Regional Pond
<br />d. Permanent Stormwater Management Not Required
<br />LOCATION OF SWPPP REQUIREMENTS IN PROJECT PLAN:
<br />DESCRIPTION
<br />LOCATION
<br />TEMPORARY EROSION CONTROL MEASURES
<br />SHEETS No. 20 - 27
<br />FINAL STABILIZATION
<br />SHEETS No. 20 - 27
<br />STORM SEWER TABULATION
<br />SHEETS No. 03
<br />EROSION AND SEDIMENT CONTROL DETAILS
<br />SHEETS No. 20 - 27
<br />EROSION AND SEDIMENT CONTROL QUANTITIES:
<br />DESCRIPTION
<br />QUANTITY
<br />BASE BID
<br />ALT BID
<br />SILT FENCE TYPE MS
<br />5143 LF
<br />583 LF
<br />INLET PROTECTION
<br />20 EA
<br />4 EA
<br />RANDOM RIP RAP CLASS III
<br />12 CY
<br />-
<br />EROSION BLANKET CATEGORY 20
<br />2326 SY
<br />52 SY
<br />CONSTRUCTION EXIT
<br />4 EA
<br />-
<br />CERTIFICATION:
<br />UNIVERSITY OF MIN`'ESOTR
<br />Joe Feriancek
<br />Design or cunslttldwn SWPPP {May 31 2023r
<br />LEGEND
<br />PROJECT LIMITS
<br />1 MILE LIMIT
<br />RECEIVING WATER
<br />IMPAIRED WATER
<br />Erosion and Stormwater
<br />Management
<br />The nog. MT. ca d t aeon [mad and is cwt5ed In Iha
<br />areaisi 6hna'h an the r/ronrsa dThis cad. Csrnfiration mans -
<br />ton chess swear Oar each Gran. son arm
<br />DATE
<br />REVISION
<br />I hereby certify that this plan, specrfication, or report was prepared
<br />by me or under my direct supervision and that I am a duly Licensed
<br />Professional Engineer u er the of the St of Minnesota
<br />!�JOE FERIANCEK
<br />Date 03721/25
<br />Lic No 57095
<br />DESIGNED BY:
<br />JJF
<br />DRAWN BY:
<br />JJF
<br />DATE
<br />03/21/25
<br />CHECKED BY:
<br />JJF
<br />FILE
<br />25-03
<br />CITY OF RAMSEY
<br />7550 SUNWOOD DRIVE
<br />RAMSEY, MN 55303
<br />(763) 427-1410 FAX (763) 433-9898
<br />SWPPP
<br />S.A.P. 199-106-012 / S.A.P 199-107-010
<br />ALPINE DRIVE RECONSTRUCTION
<br />CITY PROJECT NO. 25-03
<br />CITY OF RAMSEY, MINNESOTA
<br />SHEET
<br />18
<br />OF
<br />84