UTILITY PLAN NOTES
<br />1. ALL STORM SEWER, SANITARY SEWER AND WATERMAIN UTILITIES SHALL BE FURNISHED AND
<br />INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS,THE MINNESOTA PLUMBING
<br />CODE, THE LOCAL GOVERNING UNIT, AND THE STANDARD UTILITIES SPECIFICATION OF THE
<br />CITY ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), CURRENT EDITION.
<br />2. ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL
<br />COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION
<br />AND THE GEOTECHNICAL REPORT.
<br />3. ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF
<br />THE STATE AND LOCAL JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND
<br />BUILDING INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED
<br />AT LEAST 48 HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK
<br />IMPACTING PUBLIC UTILITIES.
<br />4. ALL SITE UTILITY SERVICES SHALL TERMINATE 5' FROM THE EXTERIOR BUILDING WALL UNLESS
<br />OTHERWISE NOTED. THE SITE UTILITY CONTRACTOR SHALL COORDINATE WITH THE GENERAL
<br />CONTRACTOR, MECHANICAL CONTRACTOR AND MECHANICAL ENGINEER TO DETERMINE THE
<br />RESPONSIBILITY OF BRINGING THE SERVICE(S) INTO THE BUILDING, INSPECTIONS AND TESTING
<br />PER APPLICABLE GOVERNING AGENCIES.
<br />5. ALL NEW WATERMAIN AND SERVICES MUST HAVE A MINIMUM OF 8.0 FEET OF COVER. EXTRA
<br />DEPTH MAY BE REQUIRED TO MAINTAIN A MINIMUM 18" VERTICAL SEPARATION TO SANITARY
<br />OR STORM SEWER LINES. THE CONTRACTOR SHALL FIELD ADJUST WATERMAIN TO AVOID
<br />CONFLICTS WITH SANITARY SEWER, STORM SEWER, AND SERVICES AS REQUIRED. INSULATION
<br />OF WATERMAIN AND SANITARY SEWER LINES SHALL BE PROVIDED WHERE 8.0 FEET MINIMUM
<br />DEPTH CAN NOT BE ATTAINED.
<br />6. PER MINNESOTA DEPARTMENT OF LABOR & INDUSTRY REQUIREMENTS, A MINIMUM OF 18
<br />INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS REQUIRED
<br />FROM WATERMAIN TO ANY MANHOLE, SEPTIC SYSTEM, CATCH BASIN, SEWER PIPE, OR OTHER
<br />SOURCE OF CONTAMINATION, MEASURED FROM THE OUTER EDGE OF THE PIPE TO THE OUTER
<br />EDGE OF THE CONTAMINATION SOURCE UNLESS OTHERWISE SHOWN.
<br />7. ALL STORM SEWER DOWNSPOUT COLLECTION PIPES AND WYES SHALL BE PVC (SCHEDULE 40).
<br />8. CONTRACTOR TO SUBMIT SHOP DRAWINGS OF SANITARY & STORM STRUCTURE(S) AND
<br />UNDERGROUND SYSTEM(S), AS APPLICABLE, FOR ENGINEER'S REVIEW.
<br />9. CONTRACTOR TO VERIFY UNDERLYING SOILS BENEATH ALL STORMWATER FACILITIES, AND
<br />PROVIDE DOCUMENTATION TO THE ENGINEER, PRIOR TO CONSTRUCTION OF THE FACILITIES.
<br />10. ALL PORTIONS OF THE SANITARY & STORM SEWER SYSTEMS, INCLUDING CATCH BASINS,
<br />LOCATED WITHIN 10 FEET OF THE BUILDING OR WATER SERVICE LINE MUST BE TESTED
<br />ACCORDANCE WITH MINNESOTA RULES, PART 4714.
<br />11. ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB OR EDGE OF PAVEMENT
<br />UNLESS OTHERWISE NOTED.
<br />z
<br />D '
<br />•�
<br />O
<br />O Lifts
<br />(
<br />Q�
<br />RIZ
<br />D
<br />13
<br />CB
<br />RIM=869.53
<br />INV=864.75
<br />(8"DIP)
<br />CB
<br />RIM=871.26
<br />INV=867.93
<br />12. HYDRANT USE: CONTRACTOR IS NOT ALLOWED TO USE HYDRANT(S). THIS ALSO APPLIES TO
<br />SUBCONTRACTORS. THE CITY HAS TWO WATER FILL STATIONS AVAILABLE. ELMCREST PARK FILL
<br />STATION & PUBLIC WORKS WATER FILL STATION. PLEASE COORDINATE WITH PUBLIC WORKS.
<br />13. OPERATING VALVES FOR TURNING WATER MAIN ON/OFF: PUBLIC UTILITIES DEPARTMENT WILL
<br />OPERATE ALL VALVES AND FILL ALL WATER MAINS (PUBLIC AND PRIVATE). CONTRACTOR SHALL
<br />GIVE AT LEAST 24 HOURS NOTICE TO HAVE WATER SHUT OFF AND SHALL NOTIFY IN WRITING,
<br />ALL AFFECTED CUSTOMERS AT LEAST 24 HOURS IN ADVANCE BEFORE SHUT OFF; ATTACH TO
<br />DOOR, ETC., NOT IN MAILBOXES.
<br />14. TEMPORARY SERVICE: THE CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE IF SERVICE
<br />CANNOT BE RESTORED SAME DAY. IF USING HYDRANT FOR TEMPORARY SERVICE, NOTIFY
<br />PUBLIC UTILITIES DEPARTMENT AND USE ONLY PRE -APPROVED HYDRANT AND SUPPLIED
<br />HYDRO METER WITH BACK FLOW. THE CONTRACTOR'S TEMPORARY MAIN SHALL BE
<br />DISINFECTED, FLUSHED AND BACTERIOLOGICAL ANALYSIS SHOWN NEGATIVE PRIOR TO
<br />PUTTING THE TEMPORARY SYSTEM IN SERVICE. THE TEMPORARY WATER SYSTEM SHALL BE IN
<br />PLACE PRIOR TO THE PUBLIC UTILITIES DEPARTMENT SHUTTING OFF ANY WATER MAINS.
<br />15. REFER TO GEOTECHNICAL EVALUATION REPORT (REPORT B2505962), DATED SEPTEMBER 11,
<br />2025 AS PREPARED BY BRAUN INTERTEC, FOR AN EXISTING SUBSURFACE SITE CONDITION
<br />ANALYSIS AND CONSTRUCTION RECOMMENDATIONS INCLUDING BUT NOT LIMITED TO:
<br />A.
<br />B.
<br />C.
<br />D.
<br />E.
<br />F.
<br />G.
<br />REUSE OF ON -SITE SOILS
<br />GROUNDWATER AND RECOMMENDATIONS FOR EXCAVATION DEWATERING.
<br />SITE GRADING AND SUBGRADE PREPARATION.
<br />PAVEMENTS AND EXTERIOR SLABS.
<br />TRENCH EXCAVATION AND BACKFILL.
<br />EXTERIOR UTILITY SUPPORTS.
<br />FROST PROTECTION.
<br />16. CONTRACTOR SHALL PROVIDE AS -BUILT INFORMATION OF CONSTRUCTED UTILITIES
<br />(RECOMMENDED PRIOR TO BACKFILLING) PER APPLICABLE PERMIT REQUIREMENTS AND/OR
<br />DEVELOPMENT AGREEMENTS.
<br />17. ALL UNUSED UTILITY SERVICES SHALL BE ABANDONED PER THE REQUIREMENTS OF THE
<br />APPLICABLE GOVERNING AGENCIES.
<br />18. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED UTILITY PERMITS FROM THE
<br />APPLICABLE GOVERNING AGENCIES.
<br />19. DUCTILE IRON PIPE (DIP) WATERMAIN: 6" OR LESS IN DIAMETER SHALL BE CLASS 53, 8" OR
<br />LARGER IN DIAMETER SHALL BE CLASS 52.
<br />4
<br />8" GV
<br />(SEE DETAIL)
<br />4
<br />4
<br />4
<br />co
<br />4
<br />4
<br />7 COMBINED 8" DOMESTIC & FIRE
<br />PROTECTION WATER SERVICE STUB
<br />(COORDINATE W/ MECHANICAL)
<br />(VERIFY SIZE, INVERT, & LOCATION W/
<br />12" ROOF DRAIN STUB
<br />(VERIFY SIZE, LOCATION,
<br />AND INV W/ MECHANICAL)
<br />PROPOSED
<br />BUILDING
<br />FFE=872.76
<br />(COORDINATE WITH
<br />APPROXIMATE LOCATION OF FDC
<br />(COORDINATE W/ MECHANICAL)
<br />(8"DIP)
<br />4
<br />4
<br />4
<br />44
<br />4
<br />El
<br />4
<br />Ramsey Parkway NW
<br />(Publicly Traveled Roadway)
<br />CONNECT TO EXISTING 8" WATERMAIN STUB
<br />(FIELD VERIFY SIZE, LOCATION, & MATERIAL)
<br />Ad
<br />8 LF 8" DIP WATERMAIN
<br />PROPOSED
<br />BUILDING
<br />FFE=875.76
<br />GFE=864.76
<br />(COORDINATE WITH
<br />48 LF 12" PVC
<br />CBMH 11
<br />RIM=869.93
<br />INV(N)=865.49
<br />INV(SE)=865.49
<br />"6
<br />] 68 LF 6" DIP WATERMAIN
<br />Lr
<br />Ingress
<br />89 LF 12" PVC
<br />4
<br />4
<br />12" ROOF DRAIN STUB
<br />/
<br />(VERIFY SIZE, LOCATION,
<br />AND INV W/ MECHANICAL)
<br />and Egress
<br />INV=867.71-\
<br />42 LF 8" PVC
<br />49 LF 18" HDPE
<br />@ 0.50%
<br />4
<br />4
<br />4
<br />4
<br />4
<br />INV=868.79
<br />33 LF 8" PVC
<br />8"X8" STORM WYE
<br />STMH 10
<br />RIM=870.85
<br />INV(NW)=865.25
<br />INV(E)=865.25
<br />FIRE HYDRANT & 6" GV-TYP.
<br />(SEE DETAIL)
<br />\_ 54 LF 8" PVC
<br />4
<br />EXTEND EX. SANITARY
<br />SEWER SERVICE
<br />INV(S)= 859.56±
<br />(FIELD VERIFY EX.
<br />LOCATION, SIZE, & INV.)
<br />4
<br />4
<br />4
<br />oo
<br />-A‘& A
<br />STUB MARKER
<br />INV=(859.15)
<br />33 LF 8" PVC
<br />8"X8" STORM WYE
<br />228 LF 18" HDPE
<br />as shown on WATERFONT VILLAGE Doc. No. 618840.0
<br />RIM=867.
<br />- CB 5
<br />CONNECT TO EXISTING 8" WATERMAIN W/ WET TAP
<br />(FIELD VERIFY SIZE, LOCATION, & MATERIAL)
<br />Easement per Doc. No. 6125'39.010
<br />CB
<br />RIM=868.46
<br />INV=862.23
<br />CBMH 4
<br />RIM=868.75
<br />PID#: 28-32-25-23-0024
<br />ADDRESS: 7895 SUNWOOD DRIVE NW, RAMSEY, MN 55303
<br />OWNER NAME: RAMSEY PROPERTIES LLC
<br />USE: COMMERCIAL SUBDISTRICT
<br />ZONING: COR-2B
<br />SMH
<br />INV=859.21
<br />A
<br />ICB-
<br />A
<br />RIM=867.38
<br />INV=862.82
<br />CB
<br />RIM=866
<br />A
<br />A
<br />A
<br />A
<br />A
<br />A
<br />CB
<br />RIM=867.18
<br />INV=862.68
<br />CB
<br />RIM=8
<br />INV-
<br />10" SANITARY SEWER SERVICE
<br />- INV=859.61
<br />(VERIFY LOCATION & INV. W/ MECHANICAL)
<br />147
<br />146 LF 18" HDPE
<br />"PVC)
<br />I I -
<br />12" ROOF DRAIN STUB
<br />(VERIFY SIZE, LOCATION,
<br />AND INV W/ MECHANICAL)
<br />CBMH 3
<br />RIM=870.79
<br />CB
<br />NO
<br />PARKING
<br />v‘l CB
<br />TRENCH DRAIN 30
<br />RIM=864.26
<br />OUTLET=862.66
<br />INSTALL TIDEFLEX CHECKMATE
<br />ULTRAFLEX INLINE CHECK VALVE
<br />(SEE DETAIL)
<br />6" 45 DEG. BEND -
<br />13 LF 6" DIP WATERMAIN
<br />6" 45 DEG. BEND
<br />49 LF 6" DIP WATERMAIN
<br />FIRE HYDRANT & 6"GV-TYP.
<br />(SEE DETAIL)
<br />6" 45 DEG. BEND
<br />14 LF 6" DIP WATERMAIN
<br />RIM=868.24
<br />INV=862.24 N
<br />INV=861.54 S;W
<br />100 LF 6"
<br />DRAINTILE
<br />6" 45 DEG. BEND
<br />11 LF 6" DIP WATERMAIN
<br />STMH 2
<br />RIM=870.81
<br />41 LF 12" HDPE
<br />CBMH 20
<br />RIM=870.33
<br />4
<br />00
<br />41 LF 12" HDPE
<br />10 N;S
<br />AN;
<br />STMH
<br />RIM=869.37
<br />INV=(863.90) NE
<br />(SI
<br />---- CONNECT TO EX. STRUCTURE
<br />@ INV(W)=862.24
<br />/ CB
<br />RIM=867.66
<br />INV=863.76
<br />WATERMAIN UNDER RETAINING WALL '''/Z7
<br />(OR APPROVED EQUAL)
<br />45 LF WATERMAIN INSULATION
<br />61 LF 6" DIP WATERMAIN
<br />CONNECT TO EXISTING 8" WATERMAIN STUB /
<br />8"X6" REDUCER
<br />(FIELD VERIFY SIZE, LOCATION, & MATERIAL)
<br />21 LF 12" HDPE
<br />re
<br />BUILD STMH 1 OVER EX.
<br />RIM=869.24
<br />INV(NW)=865.20
<br />SUMP=859.03
<br />(FIELD VERIFY
<br />LOCATION & INVERT)
<br />SCALE
<br />LINE
<br />20
<br />IN FEET
<br />40
<br />LEGEND
<br />EXISTING
<br />0
<br />0
<br />FM
<br />ELE
<br />FO
<br />GAS
<br />TEL
<br />OH
<br />CATCH BASIN
<br />STORM MANHOLE
<br />FLARED END SECTION
<br />SANITARY MANHOLE
<br />HYDRANT
<br />GATE VALVE
<br />POST INDICATOR VALVE
<br />WATER MANHOLE / WELL
<br />LIGHT POLE
<br />POWER POLE
<br />ELECTRIC METER
<br />GAS METER
<br />TELEPHONE PEDESTAL
<br />SIGN
<br />BENCHMARK
<br />SOIL BORING
<br />PARKING STALL COUNT
<br />ACCESSIBLE PARKING STALL
<br />STORM SEWER
<br />DRAINTILE
<br />SANITARY SEWER
<br />FORCEMAIN
<br />WATERMAIN
<br />SANITARY SEWER SERVICE
<br />WATER SERVICE
<br />UNDERGROUND ELECTRIC
<br />UNDERGROUND FIBER OPTIC
<br />UNDERGROUND GAS
<br />UNDERGROUND TELEPHONE
<br />OVERHEAD UTILITY
<br />FENCE
<br />CHAIN LINK FENCE
<br />CONCRETE CURB
<br />RETAINING WALL
<br />CONCRETE
<br />NO PARKING
<br />BUILDING
<br />CONTOUR
<br />SPOT ELEVATION
<br />DIRECTION OF FLOW
<br />TREE LINE
<br />PARKING SETBACK LINE
<br />PROPOSED
<br />:110
<br />•
<br />4
<br />7979
<br />SUNWOOD DR.
<br />MIXED -USE
<br />7979 SUNWOOD DRIVE
<br />RAMSEY, MN
<br />ROERS
<br />COMPANIES
<br />:. LOUCKS
<br />ELE
<br />FO
<br />TEL
<br />OH
<br />0-0-
<br />BTL
<br />NOTE:
<br />EXISTING CONDITIONS INFORMATION
<br />SHOWN IS FROM AN ALTA/NSPS LAND
<br />TITLE SURVEY PREPARED BY LOUCKS,
<br />CALL BEFORE YOU DIG!
<br />Gopher State One Call
<br />TWIN CITY AREA: 651-454-0002
<br />TOLL FREE: 1-800-252-1166
<br />WARNING:
<br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL
<br />EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN
<br />MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES.
<br />THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT
<br />LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES,
<br />CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE
<br />DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED
<br />DURING CONSTRUCTION AT NO COST TO THE OWNER.
<br />CIVIL ENGINEERING
<br />LANDSCAPE ARCHITECTURE
<br />LAND SURVEYING
<br />12755 Highway 55, Suite R100
<br />Plymouth, MN 55441
<br />763.424.5505
<br />CADD QUALIFICATION
<br />CADD files prepared by the Consultant for this project are
<br />instruments of the Consultant professional services for use solely
<br />with respect to this project. These CADD files shall not be used
<br />on other projects, for additions to this project, or for completion
<br />of this project by others without written approval by the
<br />Consultant. With the Consultant's approval, others may be
<br />permitted to obtain copies of the CADD drawing files for
<br />information and reference only. All intentional or unintentional
<br />revisions, additions, or deletions to these CADD files shall be
<br />made at the full risk of that party making such revisions, additions
<br />or deletions and that party shall hold harmless and indemnify the
<br />Consultant from any & all responsibilities, claims, and liabilities.
<br />SUBMITTAL/REVISIONS
<br />08/07/2025 SCHEMATIC PAGE FLIP
<br />08/18/2025 LAND USE APPLICATION
<br />08/22/2025 SCHEMATIC DESIGN
<br />09/11/2025 CITY RESUBMITTAL
<br />PROFESSIONAL SIGNATURE
<br />I hereby certify that this plan, specification or
<br />prepared by me or under my direct supervis
<br />laws of the State of Minnesota.
<br />Date 91V%
<br />License
<br />56088
<br />QUALITY CONTROL
<br />Loucks Project
<br />Project Lead
<br />Drawn By
<br />Checked By
<br />Review Date
<br />No.
<br />250244.00
<br />SRT
<br />LAH
<br />SRT
<br />09/10/2025
<br />SHEET INDEX
<br />C1-1 EX. COND. & SITE DEMO PLAN
<br />C1-2 CONST. STAGING PLAN
<br />C2-1
<br />C2-2
<br />C2-3
<br />C3-1
<br />C3-2
<br />C3-3
<br />C4-1
<br />C8-1 - C8-3
<br />SITE PLAN
<br />ACCESSIBLE ROUTE PLAN
<br />TURNING MOVEMENTS
<br />GRADING PLAN
<br />SWPPP
<br />SWPPP NOTES
<br />UTILITY PLAN
<br />CIVIL DETAILS
<br />LANDSCAPE PLAN
<br />LANDSCAPE DETAILS
<br />UTILITY PLAN
<br />C4-1
<br />
|