14047 Azurite St NW Building 3 December 22, 2025 <br /> <br />6 | Page <br /> <br />Actual occupancy for plumbing fixtures is less than 25. <br /> <br />NOTES ON THE TOTAL NUMBER OF PLUMBING FIXTURES: <br />The number of fixtures for a floor may not match total number of fixtures per area. <br />1. Fixtures for accessory areas are not included in the floor total. <br />2. The number of fixtures for each area are rounded up to the next whole number. Floor totals are <br />not rounded up until the floor total is obtained. <br />If the fixtures only serve an area, use number shown for each area. <br />If the fixtures serve an entire floor, use number shown for totals. <br /> <br />[P] 2902.2 Separate facilities. <br />Where plumbing fixtures are required, separate facilities shall be provided for each sex. <br />Exceptions: <br />2. Separate facilities shall not be required in structures or tenant spaces with a <br />total occupant load, including both employees and customers, of 25 or less. <br /> <br />[P] 2902.3.3 Location of toilet facilities in occupancies other than malls. <br />In occupancies other than covered and open mall buildings, the required public and employee <br />toilet facilities shall exceed a distance of 500 feet. <br /> <br />FIRE-RESISTANCE REQUIREMENTS: <br />FIRE-RESISTANCE RATING FOR EXTERIOR WALLS: <br />North Side: <br />Group S1 - Bearing walls = 0-hr Nonbearing walls = 0-hr rating on the inside. (705.5, Tables <br />601 & 602) <br /> <br />Projections extending beyond the exterior wall cannot extend closer to than 20 feet to the fire <br />separation distance line. (Table 705.2) <br /> No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) <br />Combustible projections extending within 5 feet of the line used to determine the fire separation <br />distance or located where openings are not permitted or where protection of openings are <br />required shall be of at least 1-hour fire-resistive-rated construction, Type IV or fire-retardant- <br />treated wood. (705.2.3) <br /> <br />East Side: <br />Group S1 - Bearing walls = 0-hr Nonbearing walls = 0-hr rating on the inside. (705.5, Tables <br />601 & 602) <br /> <br />Projections extending beyond the exterior wall cannot extend closer to than 20 feet to the fire <br />separation distance line. (Table 705.2) <br /> No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) <br />Combustible projections extending within 5 feet of the line used to determine the fire separation <br />distance or located where openings are not permitted or where protection of openings are <br />required shall be of at least 1-hour fire-resistive-rated construction, Type IV or fire-retardant- <br />treated wood. (705.2.3) <br />